FLEXI-SEAL FECAL MANAGEMENT SYSTEM
Report
- Report Number
- 1049092-2016-00444
- Event Type
- Malfunction
- Date Received
- October 20, 2016
- Date of Event
- September 29, 2016
- Report Date
- October 3, 2016
- Manufacturer
- CONVATEC INC.
- Product Code
- KNT
- PMA / PMN Number
- K032734
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NL
- Reporter Occupation
- NURSE
Narratives
BASED ON THE AVAILABLE INFORMATION, THIS EVENT IS DEEMED TO BE A PRODUCT MALFUNCTION. ADDITIONAL DETAILS HAVE BEEN REQUESTED BUT HAVE NOT BEEN RECEIVED TO DATE. WHEN ADDITIONAL INFORMATION BECOMES AVAILABLE, A FOLLOW-UP REPORT WILL BE SUBMITTED.
PMA/510K#: K032734 & 3RD PARTY MANUFACTURING SITE # (B)(4). NO SAMPLE RETURNED. A PREVIOUS ROOT CAUSE INVESTIGATION AND CAUSALITY ASSESSMENT FOR THIS KNOWN COMPLAINT ISSUE HAS BEEN CONDUCTED. RETENTION SAMPLES FOR FLEXI-SEAL STANDARD FMS (ICC # (B)(4)) WERE EVALUATED IN A PREVIOUS ROOT CAUSE INVESTIGATION. THE MANUFACTURING PROCESS, QUALITY INSPECTION, PACKAGING PROCESS, AND QUALITY CONTROL RECORDS WERE REVIEWED. SIMULATION TESTING INCLUDING ADHESION/TENSILE STRENGTH TESTING IN THE REVERSE DIRECTION WAS PERFORMED. THE APPEARANCE OF THE BALLOON, CATHETER BODY AND VALVE FUNCTION WERE NORMAL. NO BROKEN TUBE AND SEPARATIONS AT JOINT WERE FOUND. THE INVESTIGATION OF THE RETENTION SAMPLES FOUND THREE PROBABLE ROOT CAUSES FOR THE REPORTED MALFUNCTION AND THEY ARE AS FOLLOWS: LUMEN/SILICONE TUBE MATERIAL STRENGTH/THICKNESS. EXCESSIVE FORCE-PULL SYRINGE BEFORE COMPLETELY TWISTING LUER CONNECTION TO REMOVE THE SYRINGE AFTER USE. EXCESSIVE FORCE-ROTATIONAL FORCE WHEN ATTACHING/REMOVING SYRINGE DURING USES. THE MOST PROBABLE ROOT CAUSE WAS THE EXTERNAL FORCE WHICH EXCEEDS THE LUMEN JOINT STRENGTH OF AROUND 1.25~2.58 KG FORCE. THE INVESTIGATION DID NOT IDENTIFY ANY DEFECTS SPECIFIC TO THE LUMEN, ADHESIVE, PROCESSING, SHELF LIFE OR JHT. NO NON-CONFORMANCES FROM THE MANUFACTURING PROCESS WERE IDENTIFIED. THE RISK DOCUMENTATION ALIGNS WITH THE POST MARKET FIELD DATA FOR OCCURRENCE OF THE BROKEN LUMEN, THEREFORE, THE DESIGN IS PERFORMING AS INTENDED. ALL THE TESTING AVAILABLE SUPPORTS THAT THE PRODUCT CAN WITHSTAND A REASONABLE AMOUNT OF FORCE 1.25~2.58 KG FORCE, I.E., 12.3 N - 25.3 N. THE MALFUNCTION MAY OCCUR WHEN THE FORCE IS COMBINED WITH INCOMPLETE DETACHMENT OF THE SYRINGE FROM THE LUER LOCK. PRODUCT MONITORING REVIEWS WILL MONITOR FOR PRODUCT TRENDS IF THIS ISSUE WERE TO REOCCUR. THIS EVALUATION WILL BE CLOSED. NO ADDITIONAL PATIENT/EVENT DETAILS HAVE BEEN PROVIDED TO DATE. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, A FOLLOW-UP REPORT WILL BE SUBMITTED. REPORTED TO THE FDA ON DECEMBER 01, 2016.
REPORTER STATED "FILLING HOSE WAS LOSE IN BOX WHEN OPENING BOX." THE DEVICE WAS NOT USED. NO FURTHER INFORMATION WAS PROVIDED. NO FURTHER INFORMATION WAS PROVIDED.