THERMOCOOL® SMARTTOUCH® BI-DIRECTIONAL NAVIGATION CATHETER
Doing adverse event research by hand?
The Research Assistant searches MAUDE for you, groups reports by failure mode, and cites every record.
Free to try · every answer cites its records
Report
- Report Number
- 9673241-2016-00697
- Event Type
- Injury
- Date Received
- October 18, 2016
- Date of Event
- September 22, 2016
- Report Date
- September 22, 2016
- Manufacturer
- BIOSENSE WEBSTER, INC. (JUAREZ)
- Product Code
- LPB
- UDI-DI
- 10846835009200
- PMA / PMN Number
- P030031/S053
- Removal / Correction Number
- NA
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- VA, US
- Reporter Occupation
- OTHER
Narratives
NO DEVICE WAS RECEIVED FOR ANALYSIS AT THE TIME OF SUBMISSION OF THE INITIAL 3500A. SINCE THE PRODUCT WAS NOT RETURNED FOR ANALYSIS, NO PRODUCT FAILURE ANALYSIS CAN BE CONDUCTED AND NO DETERMINATION OF POSSIBLE CONTRIBUTING FACTORS COULD BE MADE. AS SUCH, THE INVESTIGATION WILL BE CLOSED. IF THE COMPLAINT DEVICE IS RECEIVED IN THE FUTURE WE WILL REOPEN THE COMPLAINT AND PERFORM THE INVESTIGATION AS APPROPRIATE. IF ADDITIONAL INFORMATION IS RECEIVED REGARDING THIS EVENT, A SUPPLEMENTAL 3500A REPORT WILL BE SUBMITTED TO THE FDA. THE DEVICE HISTORY RECORD (DHR) FOR THE LOT NUMBER 17509318M HAS BEEN REVIEWED AND IT WAS VERIFIED THAT DEVICE WAS MANUFACTURED IN ACCORDANCE WITH DOCUMENTED SPECIFICATIONS AND PROCEDURES. (B)(4).
(B)(4). IT WAS REPORTED THAT A PATIENT UNDERWENT AN ABLATION PROCEDURE FOR ATRIAL FIBRILLATION WITH A THERMOCOOL SMARTTOUCH BI-DIRECTIONAL NAVIGATION CATHETER AND SUFFERED A CARDIAC TAMPONADE REQUIRING A PERICARDIOCENTESIS AND SURGICAL INTERVENTION. DURING THE PROCEDURE, A PERFORATION OF THE LEFT ATRIUM WAS NOTICED AS THE PATIENT BECAME HYPOTENSIVE. A TAMPONADE WAS CONFIRMED VIA INTRACARDIAC ECHOCARDIOGRAM. A PERICARDIOCENTESIS YIELDED A LARGE, UNSPECIFIED AMOUNT OF FLUID. THE PATIENT WAS TAKEN TO THE OPERATING ROOM TO STOP THE BLEEDING. THE PATIENT WAS REPORTED TO BE IN STABLE CONDITION AT THE TIME THE COMPLAINT WAS REPORTED. THERE IS NO INFORMATION ABOUT THE HOSPITALIZATION. THE RETURNED DEVICE WAS VISUALLY INSPECTED AND IT WAS FOUND IN NORMAL CONDITIONS. THE CATHETER WAS TESTED FOR ELECTRICAL PERFORMANCE, TEMPERATURE RESPONSE AND GENERATOR TEST AND IT WAS FOUND WITHIN SPECIFICATIONS. A DEFLECTION TEST WAS PERFORMED AND THE CATHETER PASSED. THE CATHETER WAS EVALUATED FOR EEPROM, AND THE FUNCTIONALITY OF THE SENSORS OF THE CATHETER WERE TESTED ON THE CARTO 3 SYSTEM. THE CATHETER WAS RECOGNIZED BY THE CARTO 3 SYSTEM, NO ERROR MESSAGES WERE DISPLAYED AND THE CATHETER WAS PROPERLY VISUALIZED. EEPROM DATA DEMONSTRATES THE CATHETER WAS PROPERLY CALIBRATED DURING MANUFACTURING. THE FORCE FEATURE WAS EVALUATED AND PASSED THE TEST. AN IRRIGATION TEST WAS PERFORMED AND THE CATHETER PASSED WITH NO OCCLUSION OBSERVED. THE DEVICE HISTORY RECORD (DHR) WAS REVIEWED AND NO ANOMALIES WERE FOUND RELATED TO THIS COMPLAINT. IN ADDITION, THE DHR REVIEW VERIFIES THAT THE DEVICE WAS MANUFACTURED IN ACCORDANCE WITH DOCUMENTED SPECIFICATION AND PROCEDURES. THE CATHETER PASSED ALL SPECIFICATIONS. THE ROOT CAUSE OF THE CARDIAC TAMPONADE REMAINS UNKNOWN. THE INSTRUCTIONS FOR USE (IFU) STATES THAT CAREFUL CATHETER MANIPULATION MUST BE PERFORMED IN ORDER TO AVOID CARDIAC DAMAGE, PERFORATION OR TAMPONADE.
THE BWI FAILURE ANALYSIS LAB RECEIVED THE DEVICE FOR EVALUATION ON (B)(4) 2016. THE ANALYSIS HAS BEGUN BUT IS NOT COMPLETED AT THIS TIME. WHEN THE INVESTIGATIONAL ANALYSIS HAS BEEN COMPLETED, A SUPPLEMENTAL 3500A REPORT WILL BE SUBMITTED. (B)(4).
IT WAS REPORTED THAT A PATIENT UNDERWENT AN ABLATION PROCEDURE FOR ATRIAL FIBRILLATION WITH A THERMOCOOL SMARTTOUCH BI-DIRECTIONAL NAVIGATION CATHETER AND SUFFERED A CARDIAC TAMPONADE REQUIRING A PERICARDIOCENTESIS AND SURGICAL INTERVENTION. DURING THE PROCEDURE, A PERFORATION OF THE LEFT ATRIUM WAS NOTICED AS THE PATIENT BECAME HYPOTENSIVE. A TAMPONADE WAS CONFIRMED VIA INTRACARDIAC ECHOCARDIOGRAM. A PERICARDIOCENTESIS YIELDED A LARGE, UNSPECIFIED AMOUNT OF FLUID. THE PATIENT WAS TAKEN TO THE OPERATING ROOM TO STOP THE BLEEDING. THE PATIENT WAS REPORTED TO BE IN STABLE CONDITION AT THE TIME THE COMPLAINT WAS REPORTED. THERE IS NO INFORMATION ABOUT THE HOSPITALIZATION. THE PHYSICIAN DID NOT PROVIDE A CAUSALITY OPINION FOR THE CAUSE OF THIS ADVERSE EVENT. MULTIPLE ATTEMPTS HAVE BEEN MADE TO OBTAIN CLARIFICATION TO THIS COMPLAINT. HOWEVER, NO FURTHER INFORMATION HAS BEEN MADE AVAILABLE. SINCE THIS ADVERSE EVENT REQUIRED MEDICAL OR SURGICAL INTERVENTION TO PRECLUDE PERMANENT IMPAIRMENT OF A BODY FUNCTION OR PERMANENT DAMAGE TO A BODY STRUCTURE, IT IS TO BE CONSIDERED SERIOUS AND MDR REPORTABLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 687579 | THERMOCOOL® SMARTTOUCH® BI-DIRECTIONAL NAVIGATION CATHETER | CARDIAC ABLATION PERCUTANEOUS CATHETER | LPB | BIOSENSE WEBSTER, INC. (JUAREZ) | D-1327-05-S | 17509318M | 10846835009200 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Life Threatening| R |