EDWARDS SAPIEN XT TRANSCATHETER HEART VALVE
Report
- Report Number
- 2015691-2016-03081
- Event Type
- Death
- Date Received
- October 17, 2016
- Date of Event
- September 23, 2016
- Report Date
- September 23, 2016
- Manufacturer
- EDWARDS LIFESCIENCES
- Product Code
- NPT
- PMA / PMN Number
- P130009
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA
- Reporter Occupation
- PHYSICIAN
Narratives
PER THE INSTRUCTIONS FOR USE (IFU) CARDIOVASCULAR INJURY, SUCH AS PERFORATION DISSECTION OF VESSELS, VENTRICLE, MYOCARDIUM OR VALVULAR STRUCTURES, IS A KNOWN POTENTIAL COMPLICATION ASSOCIATED WITH THE TAVR PROCEDURE. ACCORDING TO THE THV TRAINING MANUALS, RISK FACTORS FOR AORTIC DISSECTION, HEMATOMA OR ANNULAR RUPTURE DURING THE TAVR PROCEDURE INCLUDE SIGNIFICANT THV OVER SIZING, SEVERELY OBLITERATED SINUSES OF VALSALVA, PORCELAIN AORTA AND/OR PRESENCE OF BULKY CALCIFICATION AND NARROW CALCIFIED STJ. IN ADDITION, ADVANCED AGE, FEMALE GENDER, SMALL BODY WEIGHT, AND STEROID DEPENDENCY CAN ALSO BE CONTRIBUTING FACTORS. THE SAPIEN VALVE RELIES ON NATIVE VALVE CALCIUM TO SECURELY ANCHOR TO THE ANNULUS. DESPITE THIS BENEFICIAL ASPECT OF CALCIUM, BULKY CALCIUM CAN INCREASE THE RISK OF CALCIFIC NODULE DISPLACEMENT INTO THE VASCULATURE, WHICH CAN LEAD TO VASCULAR INJURY. AT TIMES THE EXTENT AND DISTRIBUTION OF CALCIUM CAN IMPAIR EASE OF DELIVERY OF THE VALVE, CORRECT POSITIONING OF THE VALVE, DEPLOYMENT OF THE VALVE AND PROCEDURAL SUCCESS. IN THIS CASE, BASED ON THE LIMITED INFORMATION AVAILABLE THE ANNULAR RUPTURE WAS MOST LIKELY RELATED TO THE MECHANISMS DESCRIBED ABOVE. THE IFU AND TRAINING MANUALS HAVE BEEN REVIEWED AND NO INADEQUACIES HAVE BEEN IDENTIFIED WITH REGARDS TO WARNINGS, CONTRAINDICATIONS, AND THE DIRECTIONS/CONDITIONS FOR THE SUCCESSFUL USE OF THE DEVICE. COMPLAINT HISTORIES FOR ALL REPORTED EVENTS ARE REVIEWED AGAINST TRENDING CONTROL LIMITS ON A MONTHLY BASIS, AND ANY EXCURSIONS ABOVE THE CONTROL LIMITS ARE ASSESSED AND DOCUMENTED AS PART OF THIS MONTHLY REVIEW. NO CORRECTIVE OR PREVENTATIVE ACTIONS ARE REQUIRED AT THIS TIME.
PLEASE REFERENCE RELATED MANUFACTURER REPORT NUMBER: 2015691-2016-03091 AND 2015691-2016-03110.
AS REPORTED BY THE EDWARDS (B)(4) AFFILIATE, A 29MM SAPIEN XT VALVE WAS PREPPED AND DEPLOYED INSIDE THE PATIENT'S NATIVE AORTIC VALVE. FOLLOWING VALVE DEPLOYMENT THE PATIENT EXPERIENCED A PERI-ANNULAR HEMATOMA AS OBSERVED ON ECHO, FOLLOWED BY ASYSTOLE. THE PATIENT PASSED AWAY AND AN AUTOPSY LATER CONFIRMED THE PATIENT DIED FROM AN ANNULAR RUPTURE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 685528 | EDWARDS SAPIEN XT TRANSCATHETER HEART VALVE | AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY DELIVERED | NPT | EDWARDS LIFESCIENCES | 9300TFX29 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 76 YR | Death |