FDA Adverse Event Death Summary report: N

COOK CELECT® PLATINUM NAVALIGN UNISET VENA CAVA FILTER SET

MDR report key: 5986235 · Received September 29, 2016

Report

Report Number
3002808486-2016-01180
Event Type
Death
Date Received
September 29, 2016
Date of Event
September 22, 2015
Report Date
July 26, 2017
Manufacturer
WILLIAM COOK EUROPE
Product Code
DTK
PMA / PMN Number
K121629
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
AL, US
Reporter Occupation
ATTORNEY

Narratives

Additional Manufacturer Narrative · 0

EXEMPTION NUMBER E2016032. WILLIAM COOK EUROPE APS (MANUFACTURER) IS SUBMITTING THIS REPORT ON BEHALF OF COOK MEDICAL INCORPORATED (CMI) (IMPORTER). COOK INC./ WILLIAM COOK EUROPE IS NOT ASSUMING RESPONSIBILITY FOR PATIENT DEATH, UNCLEAR THE REASON FOR DEATH. (B)(4). G1) NAME AND ADDRESS FOR IMPORTER SITE: COOK MEDICAL INCORPORATED (CMI) 400 DANIELS WAY BLOOMINGTON, IN 47404 REGISTRATION NO.: 3005580113. THE EVENT IS CURRENTLY UNDER INVESTIGATION. A SUPPLEMENTAL REPORT WILL BE PROVIDED UPON CONCLUSION. THIS REPORT IS REQUIRED BY THE FDA UNDER 21 CFR PART 803. THIS REPORT IS BASED ON UNCONFIRMED INFORMATION SUBMITTED BY OTHERS. NEITHER THE SUBMISSION OF THIS REPORT NOR ANY STATEMENT MADE IN IT IS INTENDED TO BE AN ADMISSION THAT ANY COOK DEVICE IS DEFECTIVE OR MALFUNCTIONED; THAT A DEATH OR SERIOUS INJURY OCCURRED; OR THAT ANY COOK DEVICE CAUSED OR CONTRIBUTED TO; OR IS LIKELY TO CAUSE OR CONTRIBUTE TO A DEATH OR SERIOUS INJURY IF A MALFUNCTION OCCURRED.

Additional Manufacturer Narrative · 0

EXEMPTION NUMBER E2016032. WILLIAM COOK EUROPE APS (MANUFACTURER) IS SUBMITTING THIS REPORT ON BEHALF OF COOK MEDICAL INCORPORATED (CMI) (IMPORTER). MANUFACTURER REFERENCE # (B)(4). COOK INC./ WILLIAM COOK EUROPE IS NOT ASSUMING RESPONSIBILITY FOR PATIENT DEATH, UNCLEAR THE REASON FOR DEATH. IT HAS NOT BEEN POSSIBLE TO FURTHER INVESTIGATE OR EVALUATE THIS ALLEGED EVENT BASED ON THE LIMITED INFORMATION PROVIDED TO DATE VIA THE OPERATIVE NOTE STATING "BLEEDING, POST-DEVICE DVT/PE, DEATH". COOK WILL REOPEN ITS INVESTIGATION IF FURTHER INFORMATION IS RECEIVED WARRANTING SUPPLEMENTATION IN ACCORDANCE WITH 21 C.F.R. 803.56. PE IS A KNOWN RISK IN RELATION TO FILTER IMPLANT REPORTED IN THE PUBLISHED SCIENTIFIC LITERATURE. ALSO, IT IS REPORTED THAT THE PULMONARY EMBOLISM IN SOME CASES MAY ORIGINATE FROM UPPER EXTREMITIES INSTEAD OF LOWER EXTREMITY VEINS. WITH ALL FILTERS, THERE IS SOME RISK OF FURTHER PULMONARY EMBOLISM. THIS REPORT IS REQUIRED BY THE FDA UNDER 21 CFR PART 803. THIS REPORT IS BASED ON UNCONFIRMED INFORMATION SUBMITTED BY OTHERS. NEITHER THE SUBMISSION OF THIS REPORT NOR ANY STATEMENT MADE IN IT IS INTENDED TO BE AN ADMISSION THAT ANY COOK DEVICE IS DEFECTIVE OR MALFUNCTIONED; THAT A DEATH OR SERIOUS INJURY OCCURRED; OR THAT ANY COOK DEVICE CAUSED OR CONTRIBUTED TO; OR IS LIKELY TO CAUSE OR CONTRIBUTE TO A DEATH OR SERIOUS INJURY IF A MALFUNCTION OCCURRED.

Description of Event or Problem · 0

THIS ADDITIONAL INFORMATION WAS RECEIVED ON 11/11/2016 AS FOLLOWS: THE PLAINTIFF'S HUSBAND ALLEGEDLY RECEIVED DEVICE IMPLANT VIA RIGHT FEMORAL VEIN ON (B)(6) 2015 DUE TO DVT AND PE. THE PLAINTIFF ALLEGES BLEEDING, POST-DEVICE DVT/PE, AND DEATH AFTER IMPLANT OF DEVICE.

Additional Manufacturer Narrative · 1

(B)(4). CATALOG#: UNKNOWN BUT REFERRED TO AS A COOK CELECT FILTER. SINCE CATALOG# IS UNKNOWN THE 510(K) COULD BE EITHER K061815, K073374, K090140, K112119, K121057 OR K121629. (B)(4). INVESTIGATION IS STILL IN PROGRESS.

Additional Manufacturer Narrative · 1

(B)(4). CATALOG#: IGTCFS-65-1-UNI-CELECT-PT. (B)(4). ACCORDING TO DEVICE HISTORY RECORDS, BASED ON THE LOT NUMBER PROVIDED, THERE IS NO EVIDENCE TO SUGGEST THAT THIS DEVICE WAS NOT MANUFACTURED ACCORDING TO SPECIFICATIONS OR THAT THE FILTER DID NOT PERFORM AS INTENDED, E.G., THE PREVENTION OF RECURRENT PULMONARY EMBOLISM (PE) VIA PLACEMENT IN THE VENA CAVA IN THE SITUATIONS DESCRIBED IN THE IFU. IT HAS NOT BEEN POSSIBLE TO FULLY INVESTIGATE OR EVALUATE THIS EVENT BASED ON THE LIMITED INFORMATION PROVIDED TO DATE. COOK WILL REOPEN ITS INVESTIGATION IF FURTHER INFORMATION IS RECEIVING WARRANTING SUPPLEMENTATION IN ACCORDANCE WITH 21 C.F.R. 803.56.

Additional Manufacturer Narrative · 1

(B)(4). CATALOG #: UNKNOWN BUT REFERRED TO AS A COOK CELECT FILTER. EXPIRATION DATE: UNKNOWN AS LOT # IS UNKNOWN. SINCE CATALOG # IS UNKNOWN THE 510(K) COULD BE EITHER K061815, K073374, K090140, K112119, K121057 OR K121629. UNKNOWN AS LOT # IS UNKNOWN. IT HAS NOT BEEN POSSIBLE TO INVESTIGATE THIS EVENT BASED ON THE LIMITED INFORMATION, AND WE ARE CLOSING THE REPORT UNTIL FURTHER INFORMATION IS RECEIVED. IF ADDITIONAL INFORMATION IS RECEIVED, THE REPORT WILL BE RE-OPENED FOR FURTHER INVESTIGATION.

Description of Event or Problem · 1

DESCRIPTION ACCORDING TO SHORT FORM COMPLAINT FILED: IT IS ALLEGED THAT "[PT] RECEIVED A COOK CELECT FILTER ON (B)(6) 2015." PATIENT OUTCOME: IT IS ALLEGED THAT [PT] IS DECEASED. HOSPITAL AND MEDICAL RECORDS HAVE BEEN REQUESTED BUT NOT YET PROVIDED.

Description of Event or Problem · 1

DESCRIPTION ACCORDING TO SHORT FORM COMPLAINT FILED: IT IS ALLEGED THAT "[PT] RECEIVED A COOK CELECT FILTER ON (B)(6) 2015." PATIENT OUTCOME: IT IS ALLEGED THAT [PT] IS DECEASED. HOSPITAL AND MEDICAL RECORDS HAVE BEEN REQUESTED BUT NOT YET PROVIDED.

Description of Event or Problem · 1

DESCRIPTION ACCORDING TO SHORT FORM COMPLAINT FILED: IT IS ALLEGED THAT "[PT] RECEIVED A COOK CELECT FILTER ON (B)(6) 2015." PATIENT OUTCOME: IT IS ALLEGED THAT [PT] IS DECEASED. HOSPITAL AND MEDICAL RECORDS HAVE BEEN REQUESTED BUT NOT YET PROVIDED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
639415 COOK CELECT® PLATINUM NAVALIGN UNISET VENA CAVA FILTER SET DTK FILTER, INTRAVASCULAR, CARDIOVASCULAR DTK WILLIAM COOK EUROPE

Patients

Seq Age Sex Outcome Treatment
1 60 YR Death