ARCHITECT IPTH
Report
- Report Number
- 3002809144-2016-00081
- Event Type
- Malfunction
- Date Received
- September 20, 2016
- Report Date
- October 19, 2016
- Manufacturer
- ABBOTT GERMANY
- Product Code
- CEW
- PMA / PMN Number
- K063232
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AR
- Reporter Occupation
- HEALTH PROFESSIONAL
Narratives
AN EVALUATION IS IN PROCESS. A FOLLOW-UP REPORT WILL BE SUBMITTED WHEN THE EVALUATION IS COMPLETE. THIS REPORT IS BEING FILED ON AN INTERNATIONAL PRODUCT, LIST NUMBER 8K25-25 THAT HAS A SIMILAR PRODUCT DISTRIBUTED IN THE US, LIST NUMBER 8K25-27.
THE CUSTOMER STATED THAT THE ARCHITECT INTACT PTH ASSAY RESULTS WERE ELEVATED WHEN TESTING PATIENT RESULTS. A REVIEW OF COMPLAINT REPORTS RECEIVED TO DATE IDENTIFIED NORMAL COMPLAINT ACTIVITY FOR THIS ISSUE. ACCURACY TESTING WAS PERFORMED WITH A FILE KIT OF LOT 00415I000 AND ALL RESULTS MET ACCEPTANCE CRITERIA. THE CUSTOMER WAS REFERRED TO A STUDY, "PERFORMANCE CHARACTERISTICS OF SIX INTACT PARATHYROID HORMONE ASSAYS". SONIA L. LA'ULU, AND WILLIAM L. ROBERTS, MD, PHD. AM J CLIN PATHOL 2010; 134:930-938, 2010 FOR ADDITIONAL INFORMATION. THE ARCHITECT INTACT PTH PACKAGE INSERT WAS REVIEWED AND THE CUSTOMER WAS DIRECTED TO THE "LIMITATIONS OF THE PROCEDURE" SECTION AND ALSO THE "EXPECTED VALUES" SECTION. PER LABELING THE PRODUCT CLAIM INDICATES A POSITIVE BIAS TO THE COMPARISON ASSAY. THERE WAS NO PRODUCT DEFICIENCY IDENTIFIED FOR THIS ISSUE. IN ADDITION, THERE IS NOT ENOUGH INFORMATION TO REASONABLY SUGGEST A MALFUNCTION HAD OCCURRED. BASED ON THIS INVESTIGATION IT HAS BEEN DETERMINED THAT THE ARCHITECT INTACT PTH ASSAY, LOT 00451I000 IS PERFORMING AS INTENDED.
THE CUSTOMER STATED THAT THE ARCHITECT ANALYZER GENERATED FALSELY ELEVATED IPTH RESULTS ON EDTA SAMPLES STORED AT -20 C. PHYSICIANS COMMENTED THESE RESULTS COULD NOT BE CORRECT SO THE SITE SENT THE SAMPLES TO ANOTHER LAB WHERE THE RESULTS GENERATED WERE CLOSER TO PATIENT CLINICAL HISTORY. SAMPLES WERE PROCESSED BETWEEN (B)(6) 2016 WITH THE MEAN BEING 84.5PG/ML (NORMAL = 35 PG/ML). THE SITE PERFORMED A REGRESSION AND SAW A DIFFERENCE OF 40% IN ALL CASES. THERE WAS NO REPORTED IMPACT TO PATIENT MANAGEMENT. THERE WAS NO ADDITIONAL PATIENT INFORMATION PROVIDED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 614766 | ARCHITECT IPTH | INTACT PARATHYROID HORMONE | CEW | ABBOTT GERMANY | 00415I000 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | ARCHITECT I1000SR ANALYZER, LIST # 01L86-01,| SERIAL # (B)(4) |