FDA Adverse Event Injury Summary report: N

NAIL, FIXATION, BONE

MDR report key: 5881961 · Received August 17, 2016

Report

Report Number
2520274-2016-14108
Event Type
Injury
Date Received
August 17, 2016
Report Date
July 28, 2016
Manufacturer
SYNTHES USA
Product Code
JDS
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
MA, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

JUBEL ET AL (2005). OUTCOMES AND COMPLICATIONS OF ELASTIC STABLE INTRAMEDULLARY NAILING FOR FOREARM FRACTURES IN CHILDREN. J PEDIATR ORTHOP B (2005) 14:375-380. THIS REPORT IS FOR SYNTHES TITANIUM NAILS, UNKNOWN QUANTITY, UNKNOWN LOT NUMBER. (B)(4). THE INVESTIGATION COULD NOT BE COMPLETED AND NO CONCLUSION COULD BE DRAWN, AS NO DEVICE WAS RETURNED AND NO LOT NUMBER OR PART NUMBER WAS PROVIDED. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE. (B)(4).

Description of Event or Problem · 1

THIS REPORT IS BEING FILED AFTER THE SUBSEQUENT REVIEW OF THE FOLLOWING LITERATURE ARTICLE, JUBEL ET AL (2005). OUTCOMES AND COMPLICATIONS OF ELASTIC STABLE INTRAMEDULLARY NAILING FOR FOREARM FRACTURES IN CHILDREN. J PEDIATR ORTHOP B (2005). GERMANY. THIS PROSPECTIVE STUDY INVESTIGATED MEDIUM-TERM OUTCOMES FOR 51 CHILDREN TREATED FROM 1997 TO 2001 FOR DISPLACED DIAPHYSEAL FOREARM FRACTURES WITH ELASTIC STABLE INTRAMEDULLARY NAILING. FORTY-THREE PATIENTS INCLUDED ACHIEVED EXCELLENT/GOOD FUNCTIONAL RESULTS AT AN AVERAGE FOLLOW-UP OF 38 MONTHS. FOUR PATIENTS REQUIRED OPEN FRACTURE-MANIPULATION AT SURGERY. COMPLICATIONS INCLUDED EIGHT CASES OF SOFT-TISSUE IRRITATION AT NAIL-INSERTION SITE (THREE REQUIRED SHORTENING PROCEDURES), TWO TEMPORARY RADIAL NERVE BRANCH INJURIES, FOUR MINIMAL ROTATIONAL MOBILITY DEFICITS, ONE 108 ELBOW EXTENSION DEFICIT AFTER SPLINTING, AND FIVE SMALL KELOID SCARS. ALL PATIENTS WERE PAIN-FREE, WITHOUT LIMITATIONS IN ACTIVITIES FOR DAILY LIFE OR SPORT/PLAY ACTIVITIES BY 12 MONTHS AFTER HARDWARE REMOVAL. ELASTIC STABLE INTRAMEDULLARY NAILING IS APPROPRIATE THERAPY FOR THESE INJURIES. SI'S INCLUDE: OPEN REDUCTION REQUIRED, LESION OF THE SUPERFICIAL BRANCH OF THE RADIAL NERVE, SOFT-TISSUE IRRITATION BY PROTRUDING NAIL END, SECONDARY SHORTENING OF A NAIL REQUIRED, MOBILITY DEFICITS OF THE ADJACENT JOINTS, ROTATIONAL DEFICITS OF THE FOREARM. THIS IS REPORT #1 OF 1 FOR (B)(4). THIS REPORT IS FOR SYNTHES TITANIUM NAILS

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
536706 NAIL, FIXATION, BONE JDS SYNTHES USA

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention