BAG SPIKE ADAPTER W/CHEMOLOCK
Report
- Report Number
- 2025816-2016-00074
- Event Type
- Malfunction
- Date Received
- July 22, 2016
- Date of Event
- June 22, 2016
- Report Date
- August 16, 2016
- Manufacturer
- ICU MEDICAL, INC.
- Product Code
- ONB
- PMA / PMN Number
- K131549
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CO, US
- Reporter Occupation
- NURSE
Narratives
LOT REVIEW: A REVIEW OF SUSPECT LOT# 3120611 SHOWED THAT (B)(4) UNITS WERE MANUFACTURED, TESTED, INSPECTED AND RELEASED IN SEPTEMBER OF 2015 CITING NO ANOMALIES. NOT RETURNED TO MANUFACTURER.
LOT REVIEW: A REVIEW OF SUSPECT LOT# 3120611 SHOWED THAT (B)(4) UNITS WERE MANUFACTURED, TESTED, INSPECTED AND RELEASED IN SEPTEMBER OF 2015 CITING NO ANOMALIES. VISUAL RECEIPT ANALYSIS: 1.8ML BAG SPIKE ADAPTER W/CHEMOLOCK AND VENTED CAP, SUSPECT LOT# 3120611. ONE USED CAREFUSION PUMPSET. ONE USED SPINNING SPIROS LOT# UNKNOWN. THE PUMPSET WAS SPIKED INTO THE CL3534. THE SPIROS WAS NOT CONNECTED TO THE SET. THE SETUP WAS FLUSHED AND NO LEAKS WERE OBSERVED. THE REPORTED CRACK WAS NOT IDENTIFIED. FUNCTION TESTING: A USED CL3534 CHEMOLOCK BAG SPIKE ADAPTER WAS RETURNED CONNECTED TO A CAREFUSION PUMP SET. A USED STAND ALONE SPINNING SPIROS WAS ALSO RETURNED. THE SPIN FEATURES ON BOTH THE CHEMOLOCK AND SPINNING SPIROS CONNECTORS WERE ACTIVATED. A MICROSCOPIC EXAMINATION OF BOTH THE CL3534 CHEMOLOCK BAG SPIKE ADAPTER AND SPINNING SPIROS DID NOT REVEAL ANY CRACKING. THE CL3534 CHEMOLOCK BAG SPIKE ADAPTER CONNECTED TO THE CAREFUSION PUMP SET WAS PRESSURE LEAK TESTED IN THE ACTIVATED POSITION. THERE WAS NO LEAKAGE DETECTED AT ANY LOCATION ALONG THE FLUID PATH. THE STANDALONE SPINNING SPIROS WAS PRESSURE LEAK TESTED AND NO LEAKAGE WAS DETECTED IN EITHER THE ACTIVATED OR UNACTIVATED POSITIONS. FINAL ANALYSIS SUMMARY: THE COMPLAINTS OF BREAKAGE/LEAKAGE OF THE CL3534 CHEMOLOCK BAG SPIKE ADAPTER AND USED SPINNING SPIROS WERE UNABLE TO BE CONFIRMED OR REPLICATED. BOTH PRODUCT ASSEMBLIES MET PRESSURE LEAK EXPECTATIONS OUTLINED IN THE PRODUCT PERFORMANCE SPECIFICATION. THERE WAS NO VISIBLE CRACKING OR OTHER DAMAGE VISIBLE ON THE CL3534 CHEMOLOCK BAG SPIKE ADAPTER OR SPINNING SPIROS.
COMPLAINT RECEIVED REGARDING THREE CL3534, 5" 1.8ML BAG SPIKE ADAPTER W/CHEMOLOCK AND VENTED CAP, SUSPECT LOT# 3120611 (MFD. 09/2016). IV BAG AND TUBING LEFT IN MY OFFICE WITH A NOTE THAT STATED THE BAG SPIKE ADAPTER CRACKED AGAIN ON THE CLEAR TUBING LUER PIECE RIGHT BELOW THE BLUE CLICK ON ADAPTER PORTION OF THE ADD ON DEVICE. THERE WAS UNPROTECTED CHEMO EXPOSURE REPORTED BUT NO SERIOUS ADVERSE PATIENT CONSEQUENCES REPORTED.
COMPLAINT RECEIVED REGARDING THREE CL3534, 5" 1.8ML BAG SPIKE ADAPTER W/CHEMOLOCK AND VENTED CAP, SUSPECT LOT# 3120611 (MFD. 09/2016). IV BAG AND TUBING LEFT IN MY OFFICE WITH A NOTE THAT STATED THE BAG SPIKE ADAPTER CRACKED AGAIN ON THE CLEAR TUBING LUER PIECE RIGHT BELOW THE BLUE CLICK ON ADAPTER PORTION OF THE ADD ON DEVICE. THERE WAS UNPROTECTED CHEMO EXPOSURE REPORTED BUT NO SERIOUS ADVERSE PATIENT CONSEQUENCES REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 468843 | BAG SPIKE ADAPTER W/CHEMOLOCK | BAG SPIKE ADAPTER W/CHEMOLOCK | ONB | ICU MEDICAL, INC. | CL3534 | 3120611 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |