EAGLE EYE PLATINUM SHORT TIP; EAGLE EYE PLATINUM ST CATHETER

MDR report key: 5767024 · Received July 1, 2016

Report

Report Number
2939520-2016-00041
Event Type
Injury
Date Received
July 1, 2016
Report Date
April 26, 2016
Manufacturer
VOLCANO CORPORATION
Product Code
OBJ
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
GA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THIS CASE WAS REVIEWED AND INVESTIGATED ACCORDING TO PHILIPS VOLCANO POLICY. ATTEMPTS TO OBTAIN PATIENT INFORMATION HAVE BEEN UNSUCCESSFUL. ATTEMPTS TO OBTAIN THE PATIENT INFORMATION WERE MADE VIA EMAIL AND PHONE. ALL REASONABLY KNOWN PATIENT INFORMATION IS INCLUDED IN THIS REPORT. ADDITIONAL INFORMATION OBTAINED INDICATED AN ASPIRATION CATHETER WAS USED TO REMOVE THE CLOT IN THE GUIDE CATHETER. THE CUSTOMER WAS UNABLE TO PROVIDE LOT NUMBER OR SERIAL NUMBER; THEREFORE, DOCUMENTATION RELATED TO THE DEVICE (COMPLAINT DATABASE/SFDC, NCR DATABASE, ETC.) CANNOT BE REVIEWED. ELEVEN (11) LOTS WERE RELEASED TO THE CUSTOMER BETWEEN 11/02/2015 THROUGH 04/25/2016. THE MANUFACTURING DOCUMENTATION FOR THESE 11 LOTS WAS REVIEWED. ALL RELEASED UNITS WERE MANUFACTURED IN (B)(4) AND WERE MANUFACTURED TO SPECIFICATION. THERE ARE NO NCRS OR DEVIATIONS NOTED THAT WOULD CONTRIBUTE TO THE REPORTED FAILURE. TO DATE, ONE OTHER COMPLAINT WAS REPORTED FOR THIS SAME FAILURE MODE WITHIN THESE LOTS. WE WILL CONTINUE TO MONITOR THESE TYPES OF COMPLAINTS. THE 510K CODING FOR THE POTENTIAL 11 LOTS FALL UNDER EITHER K120697 OR K143701. NO PHYSICAL PRODUCT INVESTIGATION WAS POSSIBLE AS THE DEVICE WAS DISCARDED AT THE FACILITY AND NOT RETURNED FOR ANALYSIS. ADDITIONAL INFORMATION OBTAINED INDICATED ONE PASS WAS MADE WITH THE CATHETER AND NO RESISTANCE WAS EXPERIENCED. PER THE MANUFACTURER'S MEDICAL AUTHORITY, IT IS POSSIBLE THE MANUFACTURER'S DEVICE COULD HAVE CAUSED A THROMBUS FORMATION IF THERE WERE DEVICE-RELATED FACTORS SUCH AS SURFACE IRREGULARITY, EXCESSIVE INDWELL TIME, AND/OR COATING DEFECTS. AS WE DID NOT GET THE DEVICE BACK FOR ANALYSIS AND ADDITIONAL ATTEMPTS FOR PROCEDURAL INFORMATION WAS UNSUCCESSFUL, WE ARE REPORTING THIS EVENT IN AN ABUNDANCE OF CAUTION. THE MEDICAL AUTHORITY ALSO NOTED IT WAS POSSIBLE SITE-RELATED FACTORS WERE CONTRIBUTORY.

Description of Event or Problem · 1

THE CUSTOMER REPORTED AN UNUSUAL CLOT FORMATION WAS OBSERVED IN THE VESSEL DURING PULL BACK. THE CASE WAS ABLE TO BE COMPLETED WITHOUT EXCHANGING THE IVUS FOR ANOTHER AND NO ADDITIONAL INTERVENTION WAS REQUIRED. DEVICE WAS DISPOSED OF AFTER THE PROCEDURE. THERE WAS NO PATIENT INJURY. PATIENT HAD NO PRE-EXISTING CLOTTING CONDITIONS. VESSEL: LAD.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
418352 EAGLE EYE PLATINUM SHORT TIP; EAGLE EYE PLATINUM ST CATHETER CATHETER, ULTRASOUND, INTRAVASCULAR OBJ VOLCANO CORPORATION 8900PST

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention