EAGLE EYE PLATINUM SHORT TIP; EAGLE EYE PLATINUM ST CATHETER
Report
- Report Number
- 2939520-2016-00040
- Event Type
- Injury
- Date Received
- July 1, 2016
- Report Date
- April 26, 2016
- Manufacturer
- VOLCANO CORPORATION
- Product Code
- OBJ
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GA, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
(B)(4). THIS CASE WAS REVIEWED AND INVESTIGATED ACCORDING TO PHILIPS VOLCANO POLICY. ATTEMPTS TO OBTAIN PATIENT INFORMATION HAVE BEEN UNSUCCESSFUL. ATTEMPTS TO OBTAIN THE PATIENT INFORMATION WERE MADE VIA EMAIL AND PHONE. ALL REASONABLY KNOWN PATIENT INFORMATION IS INCLUDED IN THIS REPORT. ATTEMPTS TO GAIN DATE OF PROCEDURE HAVE BEEN UNSUCCESSFUL. ADDITIONAL INFORMATION OBTAINED INDICATED AN ASPIRATION CATHETER WAS USED TO REMOVE THE CLOT. NO TESTS/LABORATORY DATA WAS AVAILABLE. THE CUSTOMER WAS UNABLE TO PROVIDE LOT NUMBER OR SERIAL NUMBER; THEREFORE, DOCUMENTATION RELATED TO THE DEVICE (COMPLAINT DATABASE/SFDC, NCR DATABASE, ETC.) CANNOT BE REVIEWED. ELEVEN (11) LOTS WERE RELEASED TO THE CUSTOMER BETWEEN 11/02/2015 THROUGH 04/25/2016. THE MANUFACTURING DOCUMENTATION FOR THESE 11 LOTS WAS REVIEWED. ALL RELEASED UNITS WERE MANUFACTURED IN COSTA RICA AND WERE MANUFACTURED TO SPECIFICATION. THERE ARE NO NCRS OR DEVIATIONS NOTED THAT WOULD CONTRIBUTE TO THE REPORTED FAILURE. TO DATE, ONE OTHER COMPLAINT WAS REPORTED FOR THIS SAME FAILURE MODE WITHIN THESE LOTS. WE WILL CONTINUE TO MONITOR THESE TYPES OF COMPLAINTS. HEALTH PROFESSION WAS AN INTERVENTIONAL CARDIOLOGIST. ATTEMPTS TO GAIN NAME HAVE BEEN UNSUCCESSFUL. OCCUPATION OF REPORTING INDIVIDUAL IS CATH LAB MANAGER. THE 510K CODING FOR THE POTENTIAL 11 LOTS FALL UNDER EITHER K120697 OR K143701. NO PHYSICAL PRODUCT INVESTIGATION WAS POSSIBLE AS THE DEVICE WAS DISCARDED AT THE FACILITY AND NOT RETURNED FOR ANALYSIS. EXPIRATION DATE IS UNKNOWN AS THE CUSTOMER WAS UNABLE TO PROVIDE LOT OR SERIAL NUMBER OF THE DEVICE. ADDITIONAL INFORMATION OBTAINED INDICATED ONE PASS WAS MADE WITH THE CATHETER AND NO RESISTANCE WAS EXPERIENCED. PER THE MANUFACTURER'S MEDICAL AUTHORITY, IT IS POSSIBLE THE MANUFACTURER'S DEVICE COULD HAVE CAUSED A THROMBUS FORMATION IF THERE WERE DEVICE-RELATED FACTORS SUCH AS SURFACE IRREGULARITY, EXCESSIVE INDWELL TIME, AND/OR COATING DEFECTS. AS WE DID NOT GET THE DEVICE BACK FOR ANALYSIS AND ADDITIONAL ATTEMPTS FOR PROCEDURAL INFORMATION WAS UNSUCCESSFUL, WE ARE REPORTING THIS EVENT IN AN ABUNDANCE OF CAUTION. THE MEDICAL AUTHORITY ALSO NOTED IT WAS POSSIBLE SITE-RELATED FACTORS WERE CONTRIBUTORY.
THE CUSTOMER REPORTED AN UNUSUAL CLOT FORMATION WAS OBSERVED IN THE VESSEL DURING PULL BACK. THE CASE WAS ABLE TO BE COMPLETED WITHOUT EXCHANGING THE IVUS FOR ANOTHER AND NO ADDITIONAL INTERVENTION WAS REQUIRED. DEVICE WAS DISPOSED OF AFTER THE PROCEDURE. THERE WAS NO PATIENT INJURY. PATIENT HAD NO PRE-EXISTING CLOTTING CONDITIONS. VESSEL: CIRC.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 418344 | EAGLE EYE PLATINUM SHORT TIP; EAGLE EYE PLATINUM ST CATHETER | CATHETER, ULTRASOUND, INTRAVASCULAR | OBJ | VOLCANO CORPORATION | 8900PST |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |