GUNTHER TULIP FEMORAL VENA CAVA FILTER SET
Report
- Report Number
- 1820334-2016-00439
- Event Type
- Malfunction
- Date Received
- June 2, 2016
- Report Date
- October 3, 2017
- Manufacturer
- COOK INC
- Product Code
- DTK
- PMA / PMN Number
- K043509
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AL, US
- Reporter Occupation
- ATTORNEY
Narratives
DATE OF EVENT) REQUESTED BUT NOT PROVIDED. CATALOG AND LOT # WAS REQUESTED BUT NOT PROVIDED. (B)(4). THE EVENT IS CURRENTLY UNDER INVESTIGATION.
(B)(4). THE EVENT IS CURRENTLY UNDER INVESTIGATION. A SUPPLEMENTAL REPORT WILL BE PROVIDED UPON CONCLUSION.
CATALOG # IGTCFS-45-FEM IS OBSOLETE. PMA/510(K) # K043509 AS PREVIOUSLY REPORTED IS INCORRECT. PMA/510(K) # IS NOT AVAILABLE FOR THIS DEVICE.
ACCORDING TO DEVICE HISTORY RECORDS, BASED ON THE LOT NUMBER PROVIDED, THERE IS NO EVIDENCE TO SUGGEST THAT THIS DEVICE WAS NOT MANUFACTURED ACCORDING TO SPECIFICATIONS OR THAT THE FILTER DID NOT PERFORM AS INTENDED, E.G., THE PREVENTION OF RECURRENT PULMONARY EMBOLISM (PE) VIA PLACEMENT IN THE VENA CAVA IN THE SITUATIONS DESCRIBED IN THE IFU. IT HAS NOT BEEN POSSIBLE TO FULLY INVESTIGATE OR EVALUATE THIS EVENT BASED ON THE LIMITED INFORMATION PROVIDED TO DATE. COOK WILL REOPEN ITS INVESTIGATION IF FURTHER INFORMATION IS RECEIVING WARRANTING SUPPLEMENTATION IN ACCORDANCE WITH 21 C.F.R. 803.56.
IT HAS NOT BEEN POSSIBLE TO FURTHER INVESTIGATE OR EVALUATE THIS ALLEGED EVENT BASED ON THE LIMITED INFORMATION PROVIDED TO DATE VIA THE OPERATIVE NOTE STATING "DEVICE IS UNABLE TO BE RETRIEVED, PAIN IN LOWER BACK¿. COOK WILL REOPEN ITS INVESTIGATION IF FURTHER INFORMATION IS RECEIVED WARRANTING SUPPLEMENTATION IN ACCORDANCE WITH 21 C.F.R. 803.56. UNKNOWN IF THE REPORTED ¿PAIN IN LOWER BACK¿ IS DIRECTLY RELATED TO THE FILTER AND UNABLE TO IDENTIFY A CORRESPONDING FAILURE MODE AT THIS POINT IN TIME. FILTER RETRIEVAL IS OCCASIONALLY DIFFICULT. THIS IS WELL-KNOWN FROM PUBLISHED SCIENTIFIC LITERATURE WHERE FILTER RETRIEVALS ARE REFERRED TO AS SIMPLE VS. COMPLEX. SEVERAL CASE REPORTS PUBLISHED IN SCIENTIFIC LITERATURE DESCRIBE COMPLEX CASES WITH SUCCESSFUL ENDOVASCULAR FILTER RETRIEVALS USING ADDITIONAL, ADVANCED TECHNIQUES. NO EVIDENCE TO SUGGEST THAT THIS DEVICE WAS NOT MANUFACTURED ACCORDING TO SPECIFICATIONS AND NOTHING INDICATES THAT THE FILTER DID NOT PERFORM AS INTENDED, E.G. INTENDED FOR THE PREVENTION OF RECURRENT PULMONARY EMBOLISM (PE) VIA PLACEMENT IN THE VENA CAVA.
(B)(4). EVALUATION- THE DEVICE WAS NOT PROVIDED TO ASSIST WITH THE INVESTIGATION. NO INFORMATION REGARDING THE EVENT HAS BEEN PROVIDED. WE HAVE INVESTIGATED BASED ON THE INFORMATION RECEIVED TO DATE, AND ARE CLOSING THE REPORT UNTIL FURTHER INFORMATION IS RECEIVED FOR INVESTIGATION. IMPOSSIBLE TO COMMENT ON ALLEGED INJURIES. THERE IS NO INFORMATION TO SUGGEST THE DEVICE WAS NOT MANUFACTURED TO SPECIFICATIONS. IF ADDITIONAL INFORMATION IS RECEIVED, THE REPORT WILL BE RE-OPENED FOR FURTHER INVESTIGATION. WE HAVE NOTIFIED APPROPRIATE PERSONNEL AND WILL CONTINUE TO MONITOR FOR SIMILAR EVENTS.
IT IS ALLEGED THAT PATIENT RECEIVED A COOK GUNTHER TULIP ON (B)(6) 2005 AT (B)(6). IT IS ALLEGED THAT PATIENT WAS INJURED WITHOUT FURTHER EXPLANATION. PATIENT IS SEEKING PUNITIVE DAMAGES. HOSPITAL AND MEDICAL RECORDS HAVE BEEN REQUESTED BUT NOT YET PROVIDED. PATIENT OUTCOME WAS NOT PROVIDED.
THIS ADDITIONAL INFORMATION WAS RECEIVED ON (B)(6) 2016 AS FOLLOWS: PLAINTIFF ALLEGEDLY RECEIVED AN IMPLANT ON (B)(6) 2005 VIA THE FEMORAL VEIN DUE TO DEEP VENOUS THROMBOPHLEBITIS WITH PULMONARY EMBOLI. PLAINTIFF IS ALLEGING DEVICE IS UNABLE TO BE RETRIEVED AND PAIN IN LOWER BACK.
IT IS ALLEGED THAT PATIENT RECEIVED A COOK GUNTHER TULIP ON (B)(6) 2005 AT (B)(6). IT IS ALLEGED THAT PATIENT WAS INJURED WITHOUT FURTHER EXPLANATION. HOSPITAL AND MEDICAL RECORDS HAVE BEEN REQUESTED BUT NOT YET PROVIDED.
IT IS ALLEGED THAT PATIENT RECEIVED A COOK GUNTHER TULIP ON (B)(6) 2005 AT (B)(6) BY DR. (B)(6). IT IS ALLEGED THAT PATIENT WAS INJURED WITHOUT FURTHER EXPLANATION. PATIENT IS SEEKING PUNITIVE DAMAGES. HOSPITAL AND MEDICAL RECORDS HAVE BEEN REQUESTED BUT NOT YET PROVIDED. PATIENT OUTCOME WAS NOT PROVIDED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 348825 | GUNTHER TULIP FEMORAL VENA CAVA FILTER SET | DTK FILTER, INTRAVASCULAR, CARDIOVASCULAR | DTK | COOK INC | N/A |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |