COOK CELECT FEMORAL VENA CAVA FILTER SET
Report
- Report Number
- 3002808486-2016-00360
- Event Type
- Injury
- Date Received
- June 2, 2016
- Date of Event
- February 15, 2013
- Report Date
- June 26, 2017
- Manufacturer
- WILLIAM COOK EUROPE
- Product Code
- DTK
- PMA / PMN Number
- K073374
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GA, US
- Reporter Occupation
- ATTORNEY
Narratives
EXEMPTION NUMBER E2016032. WILLIAM COOK EUROPE APS (MANUFACTURER) IS SUBMITTING THIS REPORT ON BEHALF OF COOK MEDICAL INCORPORATED (CMI) (IMPORTER). (B)(4). G1) NAME AND ADDRESS FOR IMPORTER SITE: COOK MEDICAL INCORPORATED (CMI) 400 DANIELS WAY BLOOMINGTON, IN 47404 REGISTRATION NO.: 3005580113. THE EVENT IS CURRENTLY UNDER INVESTIGATION. A SUPPLEMENTAL REPORT WILL BE PROVIDED UPON CONCLUSION. THIS REPORT IS REQUIRED BY THE FDA UNDER 21 CFR PART 803. THIS REPORT IS BASED ON UNCONFIRMED INFORMATION SUBMITTED BY OTHERS. NEITHER THE SUBMISSION OF THIS REPORT NOR ANY STATEMENT MADE IN IT IS INTENDED TO BE AN ADMISSION THAT ANY COOK DEVICE IS DEFECTIVE OR MALFUNCTIONED; THAT A DEATH OR SERIOUS INJURY OCCURRED; OR THAT ANY COOK DEVICE CAUSED OR CONTRIBUTED TO; OR IS LIKELY TO CAUSE OR CONTRIBUTE TO A DEATH OR SERIOUS INJURY IF A MALFUNCTION OCCURRED.
MANUFACTURER REFERENCE #(B)(4). EXEMPTION NUMBER E2016032. WILLIAM COOK EUROPE APS (MANUFACTURER) IS SUBMITTING THIS REPORT ON BEHALF OF COOK MEDICAL INCORPORATED (CMI) (IMPORTER). IT HAS NOT BEEN POSSIBLE TO FURTHER INVESTIGATE OR EVALUATE THIS ALLEGED EVENT BASED ON THE LIMITED INFORMATION PROVIDED TO DATE VIA THE OPERATIVE NOTE FROM 06/20/2016 STATING: "THE PLAINTIFF ALLEGES FRACTURE, ORGAN PERFORATION, VENA CAVA PERFORATION, MIGRATION, DEVICE UNABLE TO BE FULLY RETRIEVED, HEMORRHAGE, CIRCULATORY PROBLEMS, EDEMA, CHEST AND NECK PAIN." COOK WILL REOPEN ITS INVESTIGATION IF FURTHER INFORMATION IS RECEIVED WARRANTING SUPPLEMENTATION IN ACCORDANCE WITH 21 C.F.R. 803.56. MANIPULATION IN THE AREA OF THE FILTER IMPLANT MAY CAUSE MIGRATION OR CONTRIBUTE TO CHANGES IN THE FILTER CONFIGURATION AND PLACEMENT. VENA CAVA WALL PERFORATION IS A KNOWN POTENTIAL COMPLICATION OF VENA CAVA FILTERS. BOTH SYMPTOMATIC AND ASYMPTOMATIC EVENTS HAVE BEEN REPORTED. AMONG OTHER CAUSES, VENA CAVA WALL PERFORATION MAY INADVERTENTLY BE INITIATED BY IMPROPER DEPLOYMENT, EXCESSIVE FORCE OR MANIPULATIONS NEAR AN IMPLANTED FILTER (E.G., A SURGICAL PROCEDURE IN THE VICINITY OF A FILTER) AND (OR) PROCEDURES THAT INVOLVE OTHER DEVICES BEING PASSED THROUGH AN IN SITU FILTER. THERE IS A CURRENT DEBATE IN THE PUBLISHED SCIENTIFIC LITERATURE ON A DIFFERENTIATION BETWEEN IVC WALL PERFORATION WITH AND WITHOUT CLINICAL SEQUELAE. E.G. FILTER LEGS MAY BE OUTSIDE THE CONTRAST LUMEN ON IMAGING WITHOUT ACTUALLY PERFORATING THE IVC WALL (KNOWN AS TENTING) AND WITH NO CLINICAL SEQUELAE. IN CONTRAST, PERFORATION OF ADJACENT ORGANS IS REPORTED WITH CLINICAL SEQUELAE. FILTER FRACTURE IS A KNOWN POTENTIAL COMPLICATION OF VENA CAVA FILTERS. BOTH SYMPTOMATIC AND ASYMPTOMATIC EVENTS HAVE BEEN REPORTED. FRACTURE OF A FILTER LEG CAN BE DUE TO REPETITIVE MOTION ON A FILTER LEG IN AN UNUSUAL STRESSED POSITION. AMONG OTHER CAUSES, FILTER FRACTURE MAY BE ASSOCIATED WITH A FILTER LEG PERFORATING THE IVC, A FILTER LEG BEING CAUGHT IN A SIDE BRANCH (E.G. RENAL VEIN), EXCESSIVE FORCE OR MANIPULATIONS NEAR AN IMPLANTED FILTER (E.G. A SURGICAL PROCEDURE IN THE VICINITY OF A FILTER) AND / OR PROCEDURES THAT INVOLVE OTHER DEVICES BEING PASSED THROUGH AN IN SITU FILTER. IT HAS BEEN REPORTED THAT RETRIEVAL OF A FRACTURED FILTER OR FILTER FRAGMENTS USING ENDOVASCULAR TECHNIQUES IS POSSIBLE. FRACTURE OF THE WIRE IS A KNOWN RISK IN RELATION TO AN IMPLANTED FILTER AND REPORTED IN THE PUBLISHED SCIENTIFIC LITERATURE. IT IS KNOWN FROM THE PUBLISHED SCIENTIFIC LITERATURE THAT A FILTER FRAGMENT EMBOLIZED INTO THE HEART OR LUNG MAY BE SAFELY RETRIEVED. FILTER RETRIEVAL IS OCCASIONALLY DIFFICULT. THIS IS WELL-KNOWN FROM PUBLISHED SCIENTIFIC LITERATURE WHERE FILTER RETRIEVALS ARE REFERRED TO AS SIMPLE VS. COMPLEX. SEVERAL CASE REPORTS PUBLISHED IN SCIENTIFIC LITERATURE DESCRIBE COMPLEX CASES WITH SUCCESSFUL ENDOVASCULAR FILTER RETRIEVALS USING ADDITIONAL, ADVANCED TECHNIQUES. NO EVIDENCE TO SUGGEST THAT THIS DEVICE WAS NOT MANUFACTURED ACCORDING TO SPECIFICATIONS AND NOTHING INDICATES THAT THE FILTER DID NOT PERFORM AS INTENDED, E.G. INTENDED FOR THE PREVENTION OF RECURRENT PULMONARY EMBOLISM (PE) VIA PLACEMENT IN THE VENA CAVA.
THIS ADDITIONAL INFORMATION WAS RECEIVED ON 06/20/21016 AS FOLLOWS: THE PLAINTIFF ALLEGEDLY RECEIVED THE FILTER IMPLANT ON (B)(6) 2010 DUE TO BILATERAL PE AND RIGHT LOWER EXTREMITY DVT. CT REPORT DATED (B)(6) 2013 ALLEGES A STRUT OF THE FILTER EXTENDING LATERALLY TOWARD THE RIGHT KIDNEY. ON (B)(6) 2013, OPEN SURGERY ALLEGEDLY WAS PERFORMED, DURING WHICH THREE PRONGS OF THE FILTER EXTENDING OUT OF THE VENA CAVA WERE REMOVED AND THE VENA CAVA THEN WAS REPAIRED WITH SUTURES. THE REMAINDER OF THE FILTER WAS LEFT IN WHAT THE ATTENDING PHYSICIAN TERMED THE ¿CHRONICALLY OCCLUDED¿ VENA CAVA. FOLLOWING THE SURGERY, THE PLAINTIFF ALLEGEDLY WAS HOSPITALIZED FOR A PROLONGED PERIOD AND THEREAFTER REHABILITATION WAS NECESSARY. THE PLAINTIFF ALLEGES FRACTURE, ORGAN PERFORATION, VENA CAVA PERFORATION, MIGRATION, DEVICE UNABLE TO BE FULLY RETRIEVED, HEMORRHAGE, CIRCULATORY PROBLEMS, EDEMA, CHEST AND NECK PAIN.
(B)(4). DATE OF EVENT: UNKNOWN AS INFORMATION WAS NOT PROVIDED. LOT#: UNKNOWN AS INFORMATION WAS NOT PROVIDED. CATALOG#: UNKNOWN BUT REFERRED TO AS A COOK CELECT FILTER. EXPIRATION DATE: UNKNOWN AS LOT# IS UNKNOWN. SINCE CATALOG# IS UNKNOWN THE 510(K) COULD BE EITHER K061815, K073374 OR K090140. INVESTIGATION IS STILL IN PROGRESS.
DESCRIPTION ACCORDING TO SHORT FORM COMPLAINT FILED: IT IS ALLEGED THAT "[PT] WAS IMPLANTED WITH COOK CELECT ON (B)(6) 2010 AT (B)(6) HOSPITAL IN (B)(6)." PATIENT OUTCOME: IT IS ALLEGED THAT [PT] WAS INJURED WITHOUT FURTHER EXPLANATION. HOSPITAL AND MEDICAL RECORDS HAVE BEEN REQUESTED BUT NOT YET PROVIDED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 349168 | COOK CELECT FEMORAL VENA CAVA FILTER SET | DTK FILTER, INTRAVASCULAR, CARDIOVASCULAR | DTK | WILLIAM COOK EUROPE |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 40 YR | Life Threatening |