FDA Adverse Event Injury Summary report: N

ANEURX STENT GRAFT SYSTEM

MDR report key: 5653377 · Received May 13, 2016

Report

Report Number
2953200-2016-01016
Event Type
Injury
Date Received
May 13, 2016
Date of Event
August 19, 2002
Report Date
April 28, 2016
Manufacturer
MEDTRONIC CARDIOVASCULAR SANTA ROSA
Product Code
MIH
PMA / PMN Number
P990020
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
MO, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

THE EXACT DATES OF THE EVENTS ARE UNKNOWN. (B)(4). A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Additional Manufacturer Narrative · 1

CORRECTED INFORMATION: SEX. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 1

MEDTRONIC RECEIVED THE FOLLOWING INFORMATION OBTAINED FROM THE JOURNAL ARTICLE ENTITLED; TRANSRENAL VERSUS INFRARENAL ENDOGRAFT FIXATION: INFLUENCE ON TYPE I ENDOLEAKS. SHAMES M1, BETROS F, DENNIEN B, GRAY-WEALE A, LIPPEY E, THURSBY P, LUSBY R. ANN VASC SURG. 2002 SEP;16(5):556-61. EPUB 2002 AUG 19. ANEURX AND TALENT STENT GRAFT SYSTEMS WERE IMPLANTED IN THE PATIENT FOR THE ENDOVASCULAR TREATMENT OF ABDOMINAL AORTIC ANEURYSM. THE FOLLOWING INFORMATION IS REVIEWED IN THIS JOURNAL ARTICLE: TYPE I ENDOLEAK, MIGRATION, OCCLUSION, PULMONARY EMBOLISM, HEMATOMA, POST-OPERATIVE ANEURYSM RUPTURE, AND TYPE II ENDOLEAK. ABSTRACT THE PURPOSE OF THIS STUDY WAS TO COMPARE THE RATE OF PROXIMAL TYPE I ENDOLEAKS IN PATIENTS UNDERGOING ENDOLUMINAL REPAIR OF INFRARENAL ABDOMINAL AORTIC ANEURYSMS WITH ENDOGRAFTS HAVING EITHER TRANSRENAL OR INFRARENAL FIXATION. FROM SEPTEMBER 1998 TO MAY 2000, 42 PATIENTS RECEIVED ENDOLUMINAL AORTIC GRAFTS FOR THE TREATMENT OF INFRARENAL ABDOMINAL AORTIC ANEURYSMS. PATIENTS RECEIVED EITHER TRANSRENAL OR INFRARENAL DEVICES, BASED ON THE SURGEON'S PREFERENCE. ALL PATIENTS HAD INFRARENAL AORTIC NECK LENGTHS MEASURING AT LEAST 1.5 CM AND PROXIMAL NECK ANGULATION OF <(><<)>60 DEGREES. THE ENDOLUMINAL GRAFTS WERE OVERSIZED BY 10-20% RELATIVE TO THE DIAMETER OF THE INFRARENAL AORTA. THE PRESENCE OF ENDOLEAKS WAS DETERMINED AT THE INITIAL PROCEDURE BY CONTRAST ANGIOGRAPHY AND DURING SUBSEQUENT FOLLOW-UP AT 1 MONTH AND 3 MONTHS BY CT SCAN OR DUPLEX ULTRASOUND. NO SIGNIFICANT DIFFERENCES IN THE RATE OF PROXIMAL TYPE I ENDOLEAKS CAN BE DEMONSTRATED BETWEEN TRANSRENAL AND INFRARENAL DEVICE TYPES IN THIS SMALL COHORT. PROPER PATIENT SELECTION IS MORE IMPORTANT THAN TYPE OF PROXIMAL FIXATION IN PREVENTING ENDOLEAKS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
309261 ANEURX STENT GRAFT SYSTEM SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT MIH MEDTRONIC CARDIOVASCULAR SANTA ROSA

Patients

Seq Age Sex Outcome Treatment
1 76 YR Required Intervention