FDA Adverse Event Malfunction Summary report: N

SYNCARDIA FREEDOM AC POWER SUPPLY

MDR report key: 5642483 · Received May 9, 2016

Report

Report Number
3003761017-2016-00188
Event Type
Malfunction
Date Received
May 9, 2016
Date of Event
April 28, 2016
Report Date
April 28, 2016
Manufacturer
SYNCARDIA SYSTEMS, INC.
Product Code
LOZ
PMA / PMN Number
P030011
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
GM
Reporter Occupation
BIOMEDICAL ENGINEER

Narratives

Additional Manufacturer Narrative · 1

(B)(4).

Additional Manufacturer Narrative · 1

(B)(4).

Description of Event or Problem · 1

THIS FREEDOM HOSPITAL AC POWER SUPPLY EU WAS NOT IN PATIENT USE. THE FREEDOM HOSPITAL AC POWER SUPPLY EU IS A COMPONENT THAT ENABLES THE FREEDOM DRIVER TO BE PLUGGED INTO AN EXTERNAL POWER SOURCE. THE CUSTOMER REPORTED THAT THE GREEN CONNECTOR ON THE HOSPITAL AC POWER SUPPLY EU COULD NOT CONNECT TO ANY FREEDOM POWER ADAPTORS OR BATTERY CHARGERS. THE HOSPITAL AC POWER SUPPLY EU WAS RETURNED TO SYNCARDIA FOR EVALUATION. VISUAL INSPECTION REVEALED THAT THE CABLE CONNECTOR COVER WAS NOT IN THE CORRECT ORIENTATION. THIS PREVENTED THE HOSPITAL AC POWER SUPPLY EU FROM MAKING A PROPER CONNECTION TO PROVIDE POWER TO A FREEDOM POWER ADAPTOR OR BATTERY CHARGER. THE AC POWER SUPPLY CABLE WAS DISASSEMBLED, THE CONNECTOR KEY SLOT WAS ALIGNED WITH THE CONNECTOR COVER KEY TAB AND THE CORRECT MATING CONFIGURATION WAS OBTAINED. AFTER THE AC POWER SUPPLY CABLE WAS REASSEMBED, THE HOSPITAL AC POWER SUPPLY EU PASSED ALL REQUIRED FUNCTIONAL TESTING. THE ROOT CAUSE FOR THE OBSERVED ISSUE WAS THE INCORRECT ORIENTATION OF THE CONNECTOR COVER ON THE FREEDOM HOSPITAL AC POWER SUPPLY EU, WHICH MAY RESULT FROM PROCESSES AT THE COMPONENT SUPPLIER OR SYNCARDIA. SYNCARDIA HAS IMPLEMENTED PROCESS CONTROLS TO IDENTIFY THIS ISSUE PRIOR TO RELEASE OF FREEDOM AC POWER SUPPLIES TO FINISHED GOODS AND TO ELIMINATE THE POTENTIAL FOR RECURRENCE. THE OCCURRENCE RATE FOR THIS ISSUE IS EXTREMELY LOW AND THERE IS NO IMPACT TO THE PATIENT. THE INCORRECT ORIENTATION OF THE CONNECTOR COVER IS IMMEDIATELY IDENTIFIABLE BY HOSPITAL PERSONNEL WHEN PREPARING THE FREEDOM DRIVER FOR PATIENT USE PER SECTION 7.5 OF F-900013-EN, FREEDOM DRIVER SYSTEM OPERATOR MANUAL. THE FREEDOM DRIVER SYSTEM INCLUDES MULTIPLE POWER SOURCES AND POWER SUPPLY ACCESSORIES SUCH THAT OPERATION OF THE DRIVER IS NOT IMPACTED BY THIS ISSUE. THIS ISSUE WILL CONTINUE TO BE MONITORED AND TRENDED AS PART OF THE CUSTOMER EXPERIENCE PROCESS. SYNCARDIA HAS COMPLETED ITS EVALUATION OF THIS COMPLAINT AND IS CLOSING THIS FILE.

Description of Event or Problem · 1

THIS FREEDOM HOSPITAL AC POWER SUPPLY EU WAS NOT IN PATIENT USE. THE FREEDOM HOSPITAL AC POWER SUPPLY EU IS A COMPONENT THAT ENABLES THE FREEDOM DRIVER TO BE PLUGGED INTO AN EXTERNAL POWER SOURCE. THE CUSTOMER REPORTED THAT THE GREEN CONNECTOR ON THE HOSPITAL AC POWER SUPPLY EU COULD NOT CONNECT TO ANY FREEDOM POWER ADAPTORS OR BATTERY CHARGERS. THIS ALLEGED FAILURE MODE POSES A LOW RISK TO A PATIENT BECAUSE THIS ISSUE WAS OBSERVED WHEN THE FREEDOM HOSPITAL AC POWER SUPPLY EU WAS NOT IN USE BY A PATIENT. IN ADDITION, THE REPORTED ISSUE WOULD NOT PREVENT A FREEDOM DRIVER FROM PERFORMING ITS LIFE-SUSTAINING FUNCTIONS. THE FREEDOM DRIVER HAS A REDUNDANT POWER SOURCE OF ONBOARD BATTERIES. THE FREEDOM HOSPITAL AC POWER SUPPLY EU WILL BE RETURNED TO SYNCARDIA FOR EVALUATION. THE RESULTS OF THE INVESTIGATION WILL BE PROVIDED IN A FOLLOW-UP MDR.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
294870 SYNCARDIA FREEDOM AC POWER SUPPLY AC POWER SUPPLY LOZ SYNCARDIA SYSTEMS, INC.

Patients

Seq Age Sex Outcome Treatment
1