ENDURANT STENT GRAFT SYSTEM
Report
- Report Number
- 2953200-2016-00471
- Event Type
- Malfunction
- Date Received
- March 14, 2016
- Date of Event
- November 13, 2015
- Report Date
- February 19, 2016
- Manufacturer
- MEDTRONIC IRELAND
- Product Code
- MIH
- PMA / PMN Number
- P100021
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4).
MEDTRONIC RECEIVED THE FOLLOWING INFORMATION OBTAINED FROM THE JOURNAL ARTICLE ENTITLED; CHARACTERISTICS AND RISK FACTORS FOR TYPE 2 ENDOLEAK IN AN EAST ASIAN POPULATION FROM A (B)(4) MULTICENTER DATABASE NAOKI FUJIMURA, MD, PHD; HIDEAKI OBARA, MD, PHD; KENTARO MATSUBARA, MD, PHD; SUSUMU WATADA, MD, PHD; SHINTARO SHIBUTANI, MD, PHD; TAKURIN AKIYOSHI, MD, PHD; HIROHISA HARADA, MD, PHD; YUKO KITAGAWA, MD, PHD (CIRC J 2016; 80: 118¿123) ENDURANT STENT GRAFT SYSTEMS WERE IMPLANTED IN THE PATIENT FOR THE ENDOVASCULAR TREATMENT OF ABDOMINAL ANEURYSM REPAIR. THE FOLLOWING ADVERSE EVENTS WERE OBSERVED: TYPE I ENDOLEAK, TYPE II ENDOLEAK AND TYPE IV ENDOLEAK. BACKGROUND: CLINICALLY DISTINCT DIFFERENCES EXIST BETWEEN EAST ASIAN AND CAUCASIAN SUBJECTS, BUT DATA FOR TYPE 2 ENDOLEAK (T2EL) ARE LIMITED IN THE EAST ASIAN POPULATION. THE AIM OF THIS STUDY WAS TO ANALYZE THE CHARACTERISTICS OF EAST ASIAN T2EL USING A (B)(4) MULTICENTER DATABASE. METHODS AND RESULTS: RETROSPECTIVE ANALYSIS OF 832 ENDOVASCULAR ANEURYSM REPAIRS PERFORMED FROM 2008 TO 2014 WERE CONDUCTED. T2EL WAS OBSERVED IN 234 CASES (28.1%), AND IN 32 CASES (3.8%) IT LED TO SAC EXPANSION >5 MM CAUSED BY ISOLATED T2EL (MEDIAN FOLLOW-UP, 35.6 MONTHS). ON UNIVARIATE AND MULTIVARIATE ANALYSIS, NON-SMOKER STATUS (ODDS RATIO [OR], 2.216; P <(><<)>0.001), EXCLUDER STENT GRAFT (OR, 2.027; P<(><<)>0.001), AND T2EL AT FINAL ANGIOGRAM (OR, 2.080; P<(><<)>0.001) WERE RISK FACTORS FOR T2EL. ON MULTIVARIATE ANALYSIS FOR ISOLATED T2EL WITH SAC EXPANSION, ONLY NON-SMOKER STATUS REMAINED (OR, 2.671; P<(><<)>0.001). OTHER THAN T1EL, ISOLATED T2EL WAS THE MOST SIGNIFICANT RISK FACTOR FOR SAC EXPANSION (OR, 18.486; P<(><<)>0.001). FURTHERMORE, OUT OF 11 TRANSARTERIAL EMBOLIZATION PROCEDURES INITIATED, 4 LED TO RUPTURE DURING FOLLOW-UP. CONCLUSIONS: EAST ASIAN T2EL HAD A STRONG RELATIONSHIP WITH NON-SMOKER STATUS. ALSO, T2EL WAS A SIGNIFICANT RISK FACTOR FOR SAC EXPANSION, WHICH SOMETIMES LED TO RUPTURE EVEN AFTER INTERVENTION. ALONG WITH THE HIGH PREVALENCE OF T2EL OBSERVED, EAST ASIAN T2EL MAY NOT ALWAYS BE BENIGN.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 154640 | ENDURANT STENT GRAFT SYSTEM | SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT | MIH | MEDTRONIC IRELAND |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00080 YR |