ENDURANT STENT GRAFT SYSTEM
Report
- Report Number
- 2953200-2016-00461
- Event Type
- Injury
- Date Received
- March 14, 2016
- Date of Event
- January 13, 2015
- Report Date
- February 19, 2016
- Manufacturer
- MEDTRONIC IRELAND
- Product Code
- MIH
- PMA / PMN Number
- P100021
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4).
MEDTRONIC RECEIVED THE FOLLOWING INFORMATION OBTAINED FROM THE JOURNAL ARTICLE ENTITLED; ANALYSIS OF ANATOMICAL RISK FACTORS FOR PERSISTENT TYPE II ENDOLEAKS FOLLOWING ENDOVASCULAR ABDOMINAL AORTIC ANEURYSM REPAIR USING CT ANGIOGRAPHY. MASAYOSHI OTSU · TORU ISHIZAKA · MICHIKO WATANABE · TAKAKI HORI · HIROKI KOHNO · KEIICHI ISHIDA · MITSURU NAKAYA · GORO MATSUMIYA. DOI 10.1007/S00595-015-1115-5. SURG TODAY (2016) 46:48¿55 AN ENDURANT STENT GRAFT SYSTEMS WERE IMPLANTED IN THE PATIENT FOR THE ENDOVASCULAR TREATMENT OF ABDOMINAL AND/OR AORTOILIAC ARTERY ANEURYSM. THE FOLLOWING INFORMATION IS REVIEWED IN THIS JOURNAL ARTICLE: TYPE IB ENDOLEAK, TYPE III ENDOLEAK AND TYPE II ENDOLEAKS. ABSTRACT: PURPOSE TO PREDICT PERSISTENT TYPE II ENDOLEAKS (PT2ES) FOLLOWING ENDOVASCULAR ANEURYSM REPAIR (EVAR) OF ABDOMINAL AORTIC ANEURYSMS, WE EXAMINED FACTORS RELATED TO POST-EVAR PT2ES. METHODS EIGHTY-FOUR CASES OF EVAR WERE ANALYZED. T2ES THAT PERSISTED FOR =6 MONTHS WERE DEFINED AS PT2ES. PT2ES FLOWING FROM AN INFERIOR MESENTERIC ARTERY (IMA) AND LUMBAR ARTERY (LA) WERE TERMED PIMA-T2ES AND PLAT2ES, RESPECTIVELY. THE ANATOMICAL FACTORS CONCERNING THE ANEURYSM, IMA AND LAS WERE ASSESSED IN THE PREOPERATIVE CT ANGIOGRAPHY IMAGES. A STATISTICAL ANALYSIS WAS PERFORMED ON THE FACTORS ASSOCIATED WITH PT2ES. RESULTS THE INCIDENCE OF PT2ES WAS 25 %. PT2ES WERE ASSOCIATED WITH POSTOPERATIVE CHANGES IN THE ANEURYSM DIAMETER. A UNIVARIATE ANALYSIS SHOWED THAT A SAC THROMBUS AND THE NUMBER OF PATENT SIDE BRANCHES ARISING FROM AN ANEURYSM WERE SIGNIFICANT FACTORS ASSOCIATED WITH PT2ES. THE IMA DIAMETERS WERE SIGNIFICANTLY LARGER IN CASES OF PIMA-T2ES. THE SIGNIFICANT FACTORS ASSOCIATED WITH PLAT2ES WEREA CIRCUMFERENTIAL THROMBUS, THE NUMBER OF PATENT LAS AND THE MEAN LA DIAMETER. MULTIVARIATE ANALYSES INDICATED THAT A CIRCUMFERENTIAL THROMBUS WAS A PROTECTIVE FACTOR FOR PT2ES, WHEREAS AN IMA =2.6 MM AND EACH ADDITIONAL LA BRANCH =1.9 MM WERE POWERFUL RISK FACTORS FOR A PT2E. CONCLUSION SIGNIFICANT ANATOMICAL FACT ORS ASSOCIATED WITH PT2E WERE FOUND IN THIS STUDY. THESE FACTORS MAY BE USEFUL IN SELECTING PATIENTS FOR PERIOPERATIVE INTERVENTION.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 153604 | ENDURANT STENT GRAFT SYSTEM | SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT | MIH | MEDTRONIC IRELAND |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00084 YR | Required Intervention |