TALENT AAA STENT GRAFT
Report
- Report Number
- 2953200-2016-00451
- Event Type
- Injury
- Date Received
- March 11, 2016
- Date of Event
- January 26, 2013
- Report Date
- February 17, 2016
- Manufacturer
- MEDTRONIC CARDIOVASCULAR
- Product Code
- MIH
- PMA / PMN Number
- P070027
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FL, US
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4).
MEDTRONIC RECEIVED THE FOLLOWING INFORMATION OBTAINED FROM THE JOURNAL ARTICLE ENTITLED; FATE OF ANEURYSMAL COMMON ILIAC ARTERY LANDING ZONES USED FOR ENDOVASCULAR ANEURYSM REPAIR. CLAIRE L. GRIFFIN, MD , SALVATORE T. SCALI, MD , ROBERT J. FEEZOR, MD , CATHERINE K. CHANG, MD, KRISTINA A. GILES, MD, JAVAIRIAH FATIMA, MD, THOMAS S. HUBER, MD, PHD, AND ADAM W. BECK, MD. A TALENT AND ANEURX AAA STENT GRAFT SYSTEMS WERE IMPLANTED IN THE PATIENT FOR THE ENDOVASCULAR TREATMENT OF COMMON ILIAC ARTERY ANEURYSM. THE FOLLOWING INFORMATION IS REVIEWED IN THIS JOURNAL ARTICLE: NEUROLOGIC COMPLICATIONS WERE ALL SPINAL HEADACHES IN PATIENTS TREATED WITH AN EPIDURAL BLOOD PATCH; RENAL COMPLICATIONS WERE DOUBLING OF CREATININE LEVEL AND/OR 50% DECLINE IN ESTIMATED GLOMERULAR INFILTRATION RATE WHILE IN-HOSPITAL OR WITHIN 30 DAYS; ISCHEMIC COMPLICATIONS INCLUDED DISTAL EMBOLIZATION, LIMB OCCLUSION, ACCESS VESSEL STENOSIS, OR PELVIC ISCHEMIA. ABSTRACT PURPOSE: TO DETERMINE OUTCOMES OF ANEURYSMAL COMMON ILIAC ARTERIES (ACIA) USED FOR LANDING ZONES (LZS) DURING ENDOVASCULAR ANEURYSM REPAIR (EVAR). METHODS: THIS SINGLE-CENTER STUDY RETROSPECTIVELY COMPARED 57 EVAR PATIENTS (MEAN AGE 72±8 YEARS; 56 MEN) WITH 70 ACIAS (DIAMETER =20 MM) TO 25 CONTROL EVAR SUBJECTS (MEAN AGE 73±7 YEARS; 20 MEN) WITH 50 NORMAL (=15-MM) CIA LZS TREATED CONSECUTIVELY DURING THE SAME TIME INTERVAL. THE CIA LZ MEASUREMENTS WERE ANALYZED USING RANDOM EFFECTS LINEAR MIXED MODELS TO DETERMINE DIAMETER CHANGE OVER TIME. LIFE TABLES WERE USED TO ESTIMATE FREEDOM FROM ENDOLEAK, REINTERVENTION, AND ALL-CAUSE MORTALITY. RESULTS: THE MEAN MAXIMUM PREOPERATIVE CIA DIAMETER IN THE ACIA LZ GROUP WAS 24.8±4.5 MM (RANGE 20.0¿47.3, MEDIAN 23.9) VS 13.6±1.5 MM (RANGE 9.2¿15.0, MEDIAN 13.9).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 151659 | TALENT AAA STENT GRAFT | SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT | MIH | MEDTRONIC CARDIOVASCULAR |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00072 YR | Required Intervention |