FDA Adverse Event Injury Summary report: N

EDWARDS SAPIEN TRANSCATHETER HEART VALVE

MDR report key: 5487125 · Received March 8, 2016

Report

Report Number
2015691-2016-00715
Event Type
Injury
Date Received
March 8, 2016
Date of Event
February 16, 2016
Report Date
February 16, 2016
Manufacturer
EDWARDS LIFESCIENCES
Product Code
NPT
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
GM
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

THIS IS ONE OF FOUR MANUFACTURER REPORTS BEING SUBMITTED FOR THIS CASE. PLEASE REFERENCE RELATED MANUFACTURER REPORT NO: 2015691-2016-00714, 2015691-2016-00712. IN THIS CASE, THE EXACT VALVE MODEL NUMBER IS NOT AVAILABLE. THEREFORE, THIS REPORT WILL REFLECT AN UNKNOWN EDWARDS SAPIEN TRANSCATHETER HEART VALVE. THE POSSIBLE PMA NUMBERS ASSOCIATED WITH AN EDWARDS SAPIEN TRANSCATHETER HEART VALVE ARE LISTED BELOW. P110021- EDWARDS SAPIEN TRANSCATHETER HEART VALVE; P130009 - EDWARDS SAPIEN XT¿ TRANSCATHETER HEART VALVE; P140031- EDWARDS SAPIEN 3 TRANSCATHETER HEART VALVE WITH COMMANDER DELIVERY SYSTEM (TF INDICATION). PER THE INSTRUCTIONS FOR USE, PARAVALVULAR LEAK (PVL) IS A POTENTIAL ADVERSE EVENT ASSOCIATED WITH BIOPROSTHETIC HEART VALVES AND THE TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVR) PROCEDURE. THE PATIENT SCREENING MANUAL AND THE PROCEDURE DIDACTIC IDENTIFY SEVERAL PROCEDURAL AND ANATOMICAL FACTORS WHICH COULD CONTRIBUTE TO PVL, INCLUDING DEVICE MALPOSITION, INACCURATE MEASUREMENT OF THE NATIVE VALVE ANNULUS, UNEVEN DISTRIBUTION OF CALCIUM ON THE NATIVE VALVE, BULKY OR SEVERE CALCIFICATION, AN ELLIPTICAL ANNULUS SHAPE AND VALVE UNDER-SIZING. PHYSICIANS ARE EXTENSIVELY TRAINED BY EDWARDS BEFORE THEY ARE QUALIFIED TO USE THE SAPIEN THV. THE PATIENT SCREENING MANUAL INSTRUCTS THE OPERATOR ON PROPER AORTIC VALVE & ROOT ASSESSMENT, INCLUDING THE USE OF ECHO, AORTOGRAM AND CT TO APPROPRIATELY MEASURE THE ANNULUS DIAMETER, CONTENT AND DISTRIBUTION OF CALCIUM, AND LEAFLET CHARACTERISTICS. CONTRAINDICATIONS, IMPORTANT CONSIDERATIONS WHEN ASSESSING THE VALVE, AND CHOOSING THE PROPER THV ARE ALSO DISCUSSED. THE THV TRAINING MANUALS ALSO INSTRUCT THE OPERATOR ON PROPER POSITIONING AND DEPLOYMENT OF THE VALVE, INCLUDING ALL PROCEDURAL AND ANATOMICAL CONSIDERATIONS. DEVICE PREPARATION, APPROACH, DEPLOYMENT, IMAGING, PROCEDURE-SPECIFIC TRAINING MANUALS AND PROCTORED PROCEDURES ARE ALSO INCLUDED. IN THIS CASE, REPORTING AND CAPTURE ARE BEING DONE CONSERVATIVELY. NO ADDITIONAL PATIENT OR PROCEDURAL FACTORS WERE PROVIDED THAT COULD HELP DETERMINE A ROOT CAUSE. THE IFU AND TRAINING MANUALS HAVE BEEN REVIEWED AND NO INADEQUACIES HAVE BEEN IDENTIFIED WITH REGARDS TO WARNINGS, CONTRAINDICATIONS, AND THE DIRECTIONS/CONDITIONS FOR THE SUCCESSFUL USE OF THE DEVICE. COMPLAINT HISTORIES FOR ALL REPORTED EVENTS ARE REVIEWED AGAINST TRENDING CONTROL LIMITS ON A MONTHLY BASIS, AND ANY EXCURSIONS ABOVE THE CONTROL LIMITS ARE ASSESSED AND DOCUMENTED AS PART OF THIS MONTHLY REVIEW. NO CORRECTIVE OR PREVENTATIVE ACTIONS ARE REQUIRED.

Description of Event or Problem · 1

AS REPORTED BY OUR AFFILIATES IN (B)(4), IN THE (B)(6) SESSION A TOTAL OF 10 EDWARDS VALVES BETWEEN 2008 AND 2015 NEEDED SURGICAL EXPLANTATION. NO ADDITIONAL INFORMATION WAS PROVIDED. TWO VALVES WERE EXPLANTED DUE TO PARAVALVULAR LEAK (PVL).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
143056 EDWARDS SAPIEN TRANSCATHETER HEART VALVE AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY DELIVERED NPT EDWARDS LIFESCIENCES VALVE UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention