LEKTRAFUSE HF GENERATOR BIPOLAR
Report
- Report Number
- 2916714-2016-00147
- Event Type
- Malfunction
- Date Received
- March 2, 2016
- Date of Event
- February 1, 2016
- Report Date
- March 2, 2016
- Manufacturer
- AESCULAP AG
- Product Code
- GEI
- PMA / PMN Number
- K130596
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GM
- Reporter Occupation
- OTHER
Narratives
AESCULAP INC. (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF AESCULAP AG (MANUFACTURER). EXEMPTION NUMBER: E2014018. MANUFACTURING SITE EVALUATION: ONE GN200 SERIAL NUMBER (B)(4) BATCH NUMBER (B)(4) MANUFACTURE DATE 04/21/2015 RECEIVED FOR EVALUATION. THE DEVICE WAS IN GOOD COSMETIC CONDITION ON ITS EXTERNAL SURFACE. FUNCTIONAL AND PARAMETRIC ANALYSIS WAS COMPLETED ON THE UNIT. UPON OPENING THE HOUSING OF THE UNIT, IT WAS NOTICED THAT THERE WAS A BURST CAPACITOR ON THE PCB. THE BURST LOCATION WAS IN THE CENTER BETWEEN THE TERMINALS. MAGNIFICATION SHOWED THE DAMAGED MICA-DIELECTRIC (BURST MICA-WASHERS). BATCH HISTORY REVIEW INDICATES THIS IS THE ONLY ITEM OF THIS BATCH. EOL TESTS WERE REVIEWED AND FOUND TO BE ACCEPTABLE. THE BREAKDOWN OF THE CAPACITOR MAY HAVE RESULTED FROM: INITIAL DAMAGE BY ASSEMBLING / SOLDERING OF THE BOARD (MOST LIKELY). ELECTRICAL OVERSTRESS (EOS, UNLIKELY). DEFECT OF MANUFACTURING OF THE CAPACITOR (DAMAGE / CRACK OF THE MICA- WASHERS,VERY UNLIKELY). BLEMISHES IN THE MICA - WASHERS (IMPERFECTION OF THE MUSCOVITE STRUCTURE, VERY UNLIKELY). THE MOST LIKELY ROOT CAUSE FOR THE BREAKDOWN OF THE CAPACITOR IS AN INITIAL DAMAGE DURING THT- PLACEMENT PROCESS (BENDING CRACKS AT THE TERMINALS ) OR SOLDERING (HEAT CRACKS CAUSED THROUGH INCORRECT GRADIENT PREHEATING / COOLING). SUCH A CRACK WILL NOT IMMEDIATELY LEAD TO A FAULT. THE FAULT WILL OCCUR AFTER A COUPLE OF OPERATING HOURS, A ION- MIGRATION THROUGH THE CRACK IN THE DIELECTRIC LEADS TO A CONDUCTION BETWEEN THE ELECTRODES OF THE CAP. UNDER CERTAIN CIRCUMSTANCES SUCH A DEFECT CAN NOT BE DETECTED IN THE EOL- TEST. EOS CAN BE RULED OUT, BECAUSE THE ELECTRIC STRENGTH OF THE CAP IS SPECIFIED WITH 500V DC. ADDITIONALLY, MICA HAS A VERY LOW LOSS ANGLE, SO AN OVERSTRESS CAUSED BY HEATING UP DURING OPERATION CAN BE RULED OUT. A DEFECT DURING PRODUCTION OF THE CAP, RESPECTIVELY BLEMISHES IN THE DIELECTRIC BASE MATERIAL, IS VERY UNLIKELY BECAUSE OF THE RIGOROUS 100% TESTING PROCEDURE OF CAPS. CORRECTIVE / PREVENTIVE ACTION: NOT APPLICABLE.
COUNTRY OF COMPLAINT: (B)(6). SURGEON NOTICED THE SMELL OF CHARRED ELECTRICS WHEN THE GENERATOR WAS BEING USED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 129977 | LEKTRAFUSE HF GENERATOR BIPOLAR | GENERATOR | GEI | AESCULAP AG | GN200 | 52127030 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |