FDA Adverse Event Malfunction Summary report: N

APPLIANCE,FIXATION,SPINAL INTERVERTEBRAL BODY

MDR report key: 5409686 · Received February 4, 2016

Report

Report Number
2520274-2016-10737
Event Type
Malfunction
Date Received
February 4, 2016
Date of Event
April 18, 2012
Report Date
January 25, 2016
Manufacturer
SYNTHES USA
Product Code
KWP
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
PA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. THIS REPORT IS FOR UNKNOWN SCREW /UNKNOWN QUANTITY/UNKNOWN LOT/(OTHER NUMBER) UDI: UNKNOWN PART NUMBER, UDI IS UNAVAILABLE. THE INVESTIGATION COULD NOT BE COMPLETED AND NO CONCLUSION COULD BE DRAWN, AS NO DEVICE WAS RETURNED AND NO LOT NUMBER OR PART NUMBER WAS PROVIDED. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 1

DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

LITERATURE ARTICLE RECEIVED: THIS REPORT IS BEING FILED AFTER THE SUBSEQUENT REVIEW OF THE FOLLOWING LITERATURE ARTICLE: SONG, K.J., LEE, K.B. AND SONG, J.H.(2012) EFFICACY OF MULTILEVEL ANTERIOR CERVICAL DISCECTOMY AND FUSION VERSUS CORPECTOMY AND FUSION FOR MULTILEVEL CERVICAL SPONDYLOTIC MYELOPATHY: A MINIMUM 5-YEAR FOLLOW-UP STUDY. EUR SPINE J (2012) 21:1551-1557. SOUTH KOREA. PURPOSE OF STUDY: THE AUTHORS EVALUATED RADIOLOGIC AND CLINICAL OUTCOMES TO COMPARE THE EFFICACY OF ANTERIOR CERVICAL DISCECTOMY AND FUSION (ACDF) AND ANTERIOR CORPECTOMY AND FUSION (ACCF) FOR MULTILEVEL CERVICAL SPONDYLOTIC MYELOPATHY (CSM). PATIENT DEMOGRAPHIC: A TOTAL OF 40 PATIENTS WHO UNDERWENT ACDF OR ACCF FOR MULTILEVEL CSM WERE DIVIDED INTO TWO GROUPS. GROUP A (N = 25) UNDERWENT ACDF AND GROUP B (N = 15) ACCF. GROUP A (N = 25) INCLUDED PATIENTS WHO UNDERWENT MULTILEVEL ACDF (FIG. 1A-I), [MEAN AGE 50.3 +- 7.5 YEARS (MIN 42, MAX 73); 19 MALES AND 6 FEMALES. GROUP B (N = 15) WAS COMPRISED OF PATIENTS WHO UNDERWENT MULTILEVEL ACCF (FIG. 2A-I), [MEAN AGE 54.1 +-9.8 YEARS (MIN 45, MAX 70) 11 MALES AND 4 FEMALES. TYPE OF SURGERY: ANTERIOR CERVICAL DISCECTOMY AND FUSION (ACDF) OR ANTERIOR CORPECTOMY AND FUSION (ACCF) FOR MULTILEVEL CERVICAL SPONDYLOTIC MYELOPATHY (CSM). IMPLANTS USED: CERVICAL SPINE LOCKING PLATE(CSLP), AO SYNTHES AND UNKNOWN SCREW. THIS IS FOR GROUP A COMPLICATIONS / REPORTABLE MALFUNCTION: SCREW BACK OUT. THIS IS REPORT 4 OF 4 FOR (B)(4). THIS REPORT IS FOR AN UNKNOWN CERVICAL SPINE LOCKING PLATE(CSLP), AO SYNTHES.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
70003 APPLIANCE,FIXATION,SPINAL INTERVERTEBRAL BODY KWP SYNTHES USA

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention