FDA Adverse Event Injury Summary report: N

APPLIANCE,FIXATION, SPINAL INTERVERTEBRAL BODY

MDR report key: 5409669 · Received February 4, 2016

Report

Report Number
2520274-2016-10733
Event Type
Injury
Date Received
February 4, 2016
Date of Event
April 18, 2012
Report Date
January 25, 2016
Manufacturer
SYNTHES USA
Product Code
KWQ
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
PA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. THIS REPORT IS FOR UNKNOWN CERVICAL SPINE LOCKING PLATE(CSLP)./UNKNOWN QUANTITY/UNKNOWN LOT. (OTHER NUMBER) UDI: UNKNOWN PART NUMBER, UDI IS UNAVAILABLE. (B)(4). THE INVESTIGATION COULD NOT BE COMPLETED AND NO CONCLUSION COULD BE DRAWN, AS NO DEVICE WAS RETURNED AND NO LOT NUMBER OR PART NUMBER WAS PROVIDED. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

LITERATURE ARTICLE RECEIVED: THIS REPORT IS BEING FILED AFTER THE SUBSEQUENT REVIEW OF THE FOLLOWING LITERATURE ARTICLE: SONG, K.J., LEE, K.B. AND SONG, J.H.(2012) EFFICACY OF MULTILEVEL ANTERIOR CERVICAL DISCECTOMY AND FUSION VERSUS CORPECTOMY AND FUSION FOR MULTILEVEL CERVICAL SPONDYLOTIC MYELOPATHY: A MINIMUM 5-YEAR FOLLOW-UP STUDY. EUR SPINE J (2012) 21:1551-1557. SOUTH KOREA. PURPOSE OF STUDY: THE AUTHORS EVALUATED RADIOLOGIC AND CLINICAL OUTCOMES TO COMPARE THE EFFICACY OF ANTERIOR CERVICAL DISCECTOMY AND FUSION (ACDF) AND ANTERIOR CORPECTOMY AND FUSION (ACCF) FOR MULTILEVEL CERVICAL SPONDYLOTIC MYELOPATHY (CSM). PATIENT DEMOGRAPHIC: A TOTAL OF 40 PATIENTS WHO UNDERWENT ACDF OR ACCF FOR MULTILEVEL CSM WERE DIVIDED INTO TWO GROUPS. GROUP A (N = 25) UNDERWENT ACDF AND GROUP B (N = 15) ACCF. GROUP A (N = 25) INCLUDED PATIENTS WHO UNDERWENT MULTILEVEL ACDF (FIG. 1A-I), [MEAN AGE 50.3 ᠷ.5 YEARS (MIN 42, MAX 73); 19 MALES AND 6 FEMALES. GROUP B (N = 15) WAS COMPRISED OF PATIENTS WHO UNDERWENT MULTILEVEL ACCF (FIG. 2A-I), [MEAN AGE 54.1 +- 9.8 YEARS (MIN 45, MAX 70) 11 MALES AND 4 FEMALES. TYPE OF SURGERY: ANTERIOR CERVICAL DISCECTOMY AND FUSION (ACDF) OR ANTERIOR CORPECTOMY AND FUSION (ACCF) FOR MULTILEVEL CERVICAL SPONDYLOTIC MYELOPATHY (CSM). IMPLANTS USED: CERVICAL SPINE LOCKING PLATE(CSLP), AO SYNTHES AND UNKNOWN SCREW. THIS IS FOR GROUP B COMPLICATIONS / SERIOUS INJURIES (SI): REVISION SURGERY (1), PSEUDOARTHROSIS (2), DYSPHAGIA (3), HOARSENESS (2), DONOR SITE PAIN(4), GRAFT RELATED (MIGRATIONS, FRACTURES) (2) AND DURA TEAR (1). THIS IS REPORT 2 OF 4 FOR (B)(4). THIS REPORT IS FOR AN UNKNOWN CERVICAL SPINE LOCKING PLATE(CSLP), AO SYNTHES.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
67886 APPLIANCE,FIXATION, SPINAL INTERVERTEBRAL BODY KWQ SYNTHES USA

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention