FDA Adverse Event Injury Summary report: N

FINAL SCREWDRIVER SHAFT

MDR report key: 5305548 · Received December 17, 2015

Report

Report Number
3003853072-2015-00023
Event Type
Injury
Date Received
December 17, 2015
Date of Event
November 18, 2015
Report Date
November 25, 2015
Manufacturer
ZIMMER SPINE
Product Code
NKB
PMA / PMN Number
PK111301
Removal / Correction Number
N/A
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
SP
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

THE REVIEW OF THE DEVICE HISTORY RECORDS DID NOT REVEAL ANY NON-CONFORMANCES TO SPECIFICATIONS OR DEVIATIONS IN PROCEDURES THAT MIGHT HAVE CONTRIBUTED TO THE REPORTED EVENT. THE VISUAL EVALUATION OF THE RETURNED DEVICE CONFIRMED THAT THE DRIVER IS BROKEN ABOVE THE THREAD PART. THE CHEMICAL ANALYZES OF THE SCREWDRIVER SHOWED THAT THE RAW MATERIAL AND HARDNESS WERE CONFORMING TO SPECIFICATION. THE MICROGRAPHIC ANALYSIS SHOWED NO SURFACE DEFECTS AND NO METALLURGICAL DEFECTS. THE SURGICAL TECHNIQUE STATES "ALWAYS USE THE TORQUE LIMITING T-HANDLE FOR FINAL TIGHTENING." THE RETURN OF THE TORQUE LIMITING T-HANDLE USED DURING THE SURGERY WAS REQUESTED AND RECEIVED. THE FUNCTIONAL EVALUATION OF THE INSTINCT TORQUE LIMITING T-HANDLE SHOWED THAT THE TORQUE HANDLE USED DURING THIS SURGERY IS NON CONFORMING. THE REVIEW OF THE DEVICE HISTORY RECORD OF THE INSTINCT TORQUE LIMITING T-HANDLE (046W1AN00650 LOT A164720901) SHOWED THAT NO NON CONFORMITY WAS REGISTERED. THE UNIT WAS RECEIVED AND RELEASED IN MAY 2012. THE LIFETIME, DETERMINED IN THE DEVICE HISTORY FILES, FOR THE INSTINCT TORQUE LIMITING T-HANDLE IS 3 YEARS. IN THIS CASE, THE INSTINCT TORQUE LIMITING T-HANDLE WAS USED 3 YEARS AND 6 MONTHS ((B)(6) 2012 TO (B)(6) 2015), THEREFORE THE ROOT CAUSE IS PRODUCT EXCEEDED USEFUL LIFE, NORMAL WEAR. THE ROOT CAUSE FOR THE INSTINCT FINAL SCREWDRIVER BREAKAGE IS THE OFF AXIS USE OF THE SCREWDRIVER WITH THE INSTINCT TORQUE LIMITING T-HANDLE. . CORRECTIONS TO INITIAL REPORT: DEVICE PRODUCT CODE IS NKB, NOT HXX. PMA/510(K) NUMBER IS K111301, NOT EXEMPT. AS THE INSTINCT TORQUE LIMITING T-HANDLE WAS IDENTIFIED TO HAVE CAUSED OR CONTRIBUTED TO THE REPORTED EVENT, AN MDR WAS SUBMITTED FOR THIS DEVICE (REFERENCE 3003853072-2016-00015).

Additional Manufacturer Narrative · 1

CURRENT INFORMATION IS INSUFFICIENT TO PERMIT A VALID CONCLUSION ABOUT THE CAUSE OF THIS EVENT. A FOLLOW UP REPORT WILL BE SENT UPON COMPLETION OF THE DEVICE EVALUATION.

Description of Event or Problem · 1

IT IS REPORTED WHEN THE SURGEON LOCKED THE BLOCKERS, THE FINAL SCREWDRIVER SHAFT BROKE. THE PART OF THE INSTRUMENT THAT BROKE REMAINED INSIDE THE BLOCKER AND WAS UNABLE TO BE REMOVED FROM THE BLOCKER, WHICH REMAINS IMPLANTED IN THE PATIENT. A SECOND DRIVER WAS USED TO SUCCESSFULLY COMPLETE THE SURGERY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
834231 FINAL SCREWDRIVER SHAFT SCREWDRIVER NKB ZIMMER SPINE N/A A2102902A

Patients

Seq Age Sex Outcome Treatment
1 Other