FDA Adverse Event Malfunction Summary report: N

TI LOW PROFILE NEURO SCREW SELF-DRILLING 5MM

MDR report key: 5233669 · Received November 18, 2015

Report

Report Number
2520274-2015-17379
Event Type
Malfunction
Date Received
November 18, 2015
Date of Event
October 5, 2015
Report Date
October 11, 2015
Manufacturer
SYNTHES (USA)
Product Code
JEY
PMA / PMN Number
PK022012
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. (B)(4). (B)(6). THIS DEVICE WAS NOT INITIALLY REPORTED BY THE FACILITY BUT WAS RECEIVED BY THE MANUFACTURER ON NOV 3, 2015 FOR THE INITIALLY COMPLAINED CONDITION. WITHOUT A LOT NUMBER THE DEVICE HISTORY RECORDS REVIEW COULD NOT BE COMPLETED. THE INVESTIGATION HAS NOT BEEN COMPLETED. THE SUBJECT DEVICE HAS BEEN RECEIVED AND IS CURRENTLY IN THE EVALUATION PROCESS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 1

ADDITIONAL NARRATIVE: DEVICE INVESTIGATION SUMMARY ¿ THE COMPLAINT CONDITION FOR THE THREE (3) 400.833 3MM TITANIUM LOW PROFILE NEURO SCREWS, ONE (1) 4MM TITANIUM LOW PROFILE NEURO SCREWS, TEN (10) 5MM TITANIUM LOW PROFILE NEURO SCREWS, AND FOUR (4) 6MM TITANIUM LOW PROFILE NEURO SCREWS WITH UNKNOWN LOT NUMBERS WAS LIKELY CAUSED BY NOT DRILLING PRIOR TO SCREW INSERTION; HOWEVER, THIS COMPLAINT IS NOT LIKELY A RESULT OF ANY DESIGN RELATED DEFICIENCY. EIGHTEEN SCREWS WERE RETURNED, SIXTEEN OF WHICH ARE BROKEN AND TWO OF WHICH APPEAR TO BE INTACT. THE PART NUMBERS FOR ONE INTACT 400.834 4MM TITANIUM LOW PROFILE NEURO SCREW AND ONE INTACT 400.836 6MM TITANIUM LOW PROFILE NEURO SCREW CAN BE CONFIRMED THROUGH MEASUREMENT, BUT THE REMAINING BROKEN SCREWS CANNOT. THE SIXTEEN BROKEN SCREWS WILL BE ASSUMED TO BE THE PART NUMBERS AS REPORTED. THE EIGHTEEN TITANIUM LOW PROFILE NEURO SCREWS ARE IMPLANTS ROUTINELY USED IN THE LOW PROFILE NEURO PLATING SYSTEM. THE SCREWS WERE RETURNED AND REPORTED TO HAVE BROKEN DURING INSERTION. THIS CONDITION IS CONFIRMED; TWELVE SCREWS ARE BROKEN ALONG THE SHAFT AND FOUR SCREWS HAVE BROKEN OR ARE SIGNIFICANTLY DEFORMED AT THE VERY DISTAL SELF-DRILLING TIP OF THE SCREW. IT IS LIKELY THAT THE SURGEON DID NOT DRILL PRIOR TO INSERTION WHICH MAY HAVE LED TO THIS COMPLAINT CONDITION. THE BONE WHERE THE SCREWS WERE TO BE INSERTED MAY ALSO HAVE BEEN PARTICULARLY DENSE. THE CONDITION OF THE RETURNED SCREWS IS CONSISTENT WITH ATTEMPTED INSERTION. DEVICE DRAWINGS WERE REVIEWED AND DETERMINED TO BE SUITABLE FOR THE INTENDED DESIGN, APPLICATION AND DIMENSIONAL CONFORMITY WHEN USED AS RECOMMENDED. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

DEVICE REPORT AND ADDITIONAL INFORMATION RECEIVED ON NOVEMBER 3, 2015 FROM SYNTHES (B)(4) REPORTED AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE EIGHTEEN (18) SCREWS BROKE WHILE BEING INSERTED INTO THE PATIENT. ALL BROKEN SCREW PARTS WERE RETRIEVED FROM THE PATIENT. THE UNKNOWN PROCEDURE WAS PROLONGED 15 TO 20 MINUTES DUE TO THIS INCIDENT. THE PROCEDURE WAS COMPLETED BY USING OTHER SCREWS OF THE SAME SIZE. THERE WAS NO REPORTED HARM TO THE PATIENT AND HE IS DOING WELL. (B)(4).