FDA Adverse Event Malfunction Summary report: N

GLASSVAN

MDR report key: 5223627 · Received November 13, 2015

Report

Report Number
8040409-2015-00006
Event Type
Malfunction
Date Received
November 13, 2015
Date of Event
October 15, 2015
Report Date
January 6, 2016
Manufacturer
M/S NIRAJ INDUSTRIES PVT LTD.
Product Code
GES
PMA / PMN Number
EXEMPT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IA, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

THE INVESTIGATION INTO A ROOT CAUSE IS ONGOING. THE MANUFACTURER IS TESTING RETAIN SAMPLES OF THIS LOT CURRENTLY AND WILL UPDATE THIS REPORT. DEVICE NOT RETURNED TO THE MANUFACTURER.

Additional Manufacturer Narrative · 1

CORRECTION: DATE OF EVENT ON INITIAL SUBMISSION INCOMPLETE. ALTHOUGH THE ACTUAL DATE OF THE EVENTS WERE NOT SPECIFIC BY THE END-USER, WE LIST HERE THE DATE THE COMPLAINT WAS RECEIVED FOR REFERENCE. THIS IS AN APPROXIMATE DATE OF THE EVENT AS THE SURGEON WAS NOT SURE OF THE EXACT DATE WHICH THESE EVENTS OCCURED. ADDITIONAL NARRATIVE: THE DEFECT DEVICES WERE DISCARDED BY THE END-USER. THE REMAINDER OF THE BOX OF BLADES WAS RETURNED FROM THE DISTRIBUTOR AND EVALUATED BY THE MANUFACTURER. THE BLADES FROM THE SAME BOX WERE USED IN THE EVALUATION AND IT WAS CONCLUDED THAT "NO CRACK / BROKEN BLADES OBSERVED ON VISUAL EXAMINATION. HARDNESS AND STIFFNESS (BREAK ANGLE) OF ALL SAMPLES OBSERVED WITH IN SPECIFICATION." THE MANUFACTURER'S REPORT IS ATTACHED TO THIS FILE FOR REVIEW. NO SIMILAR COMPLAINTS OR REPORTS FROM THIS OR ANY OTHER BATCH WERE REPORTED TO DATE. THE MANUFACTURER HAS CONCLUDED THEIR INVESTIGATION, AND WE CONSIDER THIS ISSUE CLOSED.

Description of Event or Problem · 1

THE ORAL SURGEON STATED HE HAD 2 BLADES BREAK DURING THE INITIAL INCISION ON ONE PATIENT WHILE PERFORMING AN IMPACTED WISDOM TOOTH PROCEDURE. THE BLADE FRACTURED AT THE HANDLE CUTOUT BUT NO FRAGMENT WAS LEFT IN THE PATIENT. THE SECOND BLADE PREPARED FOR THE SAME PATIENT FRACTURED IN THE SAME MANNER, SO HE USED A BLADE FROM A DIFFERENT BOX WITH NO INCIDENT. HE COULD NOT CONFIRM THE BRAND OR LOT OF THE ALTERNATE THIRD BLADE USED. ON A SECOND PATIENT, THE SURGEON HAD A BLADE TIP BREAK IN THE PATIENT'S GUM AND REMOVED THE FRAGMENT USING A HEMOSTAT. THE SURGEON STATED THAT NO HARM CAME TO EITHER PATIENT. THE ORAL SURGEON STATED THAT HE WAS NOT SURE OF THE BRAND OF THE BLADE, BUT HE HAD HIS STAFF REMOVE THE REMAINDER OF THAT BOX AND SEND IT BACK TO THEIR DISTRIBUTOR. WE HAVE ATTEMPTED TO OBTAIN THESE SAMPLES BACK FROM THE DISTRIBUTOR, BUT THE BLADES WERE UNAVAILABLE WHEN THE DELIVERY DRIVER ATTEMPTED PICK UP. WE WILL CONTINUE TO TRY TO RETRIEVE THE SAMPLES OR CONFIRM THEY HAVE BEEN DISCARDED OR LOST.

Description of Event or Problem · 1

THE ORAL SURGEON STATED HE HAD 2 BLADES BREAK DURING THE INITIAL INCISION ON ONE PATIENT WHILE PERFORMING AN IMPACTED WISDOM TOOTH PROCEDURE. THE BLADE FRACTURED AT THE HANDLE CUTOUT BUT NO FRAGMENT WAS LEFT IN THE PATIENT. THE SECOND BLADE PREPARED FOR THE SAME PATIENT FRACTURED IN THE SAME MANNER, SO HE USED A BLADE FROM A DIFFERENT BOX WITH NO INCIDENT. HE COULD NOT CONFIRM THE BRAND OR LOT OF THE ALTERNATE THIRD BLADE USED. ON A SECOND PATIENT, THE SURGEON HAD A BLADE TIP BREAK IN THE PATIENT'S GUM AND REMOVED THE FRAGMENT USING A HEMOSTAT. THE SURGEON STATED THAT NO HARM CAME TO THE PATIENT. THE ORAL SURGEON STATED THAT HE WAS NOT SURE OF THE BRAND OF THE BLADE, BUT HAD HIS STAFF REMOVE THE REMAINDER OF THAT BOX AND SEND IT BACK TO THE DISTRIBUTOR. WE HAVE ATTEMPTED TO OBTAIN THESE SAMPLES BACK FROM THE DISTRIBUTOR, BUT THE BLADES WERE UNAVAILABLE WHEN THE DELIVERY DRIVER ATTEMPTED PICK UP. WE WILL CONTINUE TO TRY TO RETRIEVE THE SAMPLES OR CONFIRM THEY HAVE BEEN DISCARDED OR LOST.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
753319 GLASSVAN SURGICAL BLADE GES M/S NIRAJ INDUSTRIES PVT LTD. 151104AC

Patients

Seq Age Sex Outcome Treatment
1