M2A-MAGNUM PF CUP 56ODX50ID
Report
- Report Number
- 0001825034-2015-04445
- Event Type
- Injury
- Date Received
- October 30, 2015
- Date of Event
- August 29, 2014
- Report Date
- August 22, 2019
- Manufacturer
- BIOMET ORTHOPEDICS
- Product Code
- KWA
- PMA / PMN Number
- PK042037
- Removal / Correction Number
- N/A
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NE, US
- Reporter Occupation
- PHYSICIAN
Narratives
CURRENT INFORMATION IS INSUFFICIENT TO PERMIT A CONCLUSION AS TO THE CAUSE OF THE EVENT. REVIEW OF DEVICE HISTORY RECORDS SHOW THAT LOT RELEASED WITH NO RECORDED ANOMALY OR DEVIATION. THERE ARE WARNINGS IN THE PACKAGE INSERT THAT STATE THAT THIS TYPE OF EVENT CAN OCCUR: UNDER POSSIBLE ADVERSE EFFECTS, NUMBER 1 STATES, "MATERIAL SENSITIVITY REACTIONS." NUMBER 4 STATES, ¿LOOSENING OR MIGRATION OF THE IMPLANTS MAY OCCUR DUE TO LOSS OF FIXATION, TRAUMA, MALALIGNMENT, BONE RESORPTION, EXCESSIVE ACTIVITY.¿ NUMBER 6 STATES, "INADEQUATE RANGE OF MOTION DUE TO IMPROPER SELECTION OR POSITIONING OF COMPONENTS." NUMBER 14 STATES, "INTRAOPERATIVE OR POSTOPERATIVE BONE FRACTURE AND/OR POSTOPERATIVE PAIN." NUMBER 15 STATES, "ELEVATED METAL ION LEVELS HAVE BEEN REPORTED WITH METAL ON METAL ARTICULATING SURFACES." THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF¿S COMPLAINT, AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. THIS REPORT IS NUMBER 2 OF 2 MDRS FILED FOR THE SAME EVENT (REFERENCE 1825034-2015-03206-1 / 04445).
LEGAL COUNSEL FOR PATIENT REPORTED PATIENT UNDERWENT LEFT TOTAL HIP ARTHROPLASTY ON (B)(6), 2011. SUBSEQUENTLY, PATIENT'S LEGAL COUNSEL FURTHER REPORTED PATIENT UNDERWENT A REVISION PROCEDURE ON (B)(6), 2014 DUE TO PATIENT ALLEGATIONS OF PAIN, INFLAMMATION, BURSITIS, TISSUE DETERIORATION, AND LIMITED MOBILITY. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF'S COMPLAINT, AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. ADDITIONAL INFORMATION RECEIVED IN PATIENT'S OPERATIVE REPORT INDICATES THAT THE REVISION PROCEDURE THAT TOOK PLACE ON (B)(6), 2014 NOTED EFFUSION DUE TO METAL DEBRIS DURING THE REVISION PROCEDURE. OPERATIVE REPORT ALSO NOTED THE REVISION OF THE ACETABULAR CUP DUE TO MINIMAL BONE INGROWTH.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 723215 | M2A-MAGNUM PF CUP 56ODX50ID | PROSTHESIS, HIP | KWA | BIOMET ORTHOPEDICS | N/A | 593890 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 67 YR | Hospitalization| R | D11 MEDICAL PRODUCTS. |