REVEAL DISTAL ATTACHMENT CAP
Report
- Report Number
- 1528319-2015-00024
- Event Type
- Injury
- Date Received
- September 17, 2015
- Date of Event
- August 18, 2015
- Report Date
- September 15, 2015
- Manufacturer
- UNITED STATES ENDOSCOPY GROUP, INC.
- Product Code
- OCX
- PMA / PMN Number
- K140315
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TX, US
- Reporter Occupation
- PHYSICIAN
Narratives
THE REVEAL DISTAL ATTACHMENT CAP HAS BEEN DESIGNED TO BE ATTACHED TO THE DISTAL END OF THE ENDOSCOPE TO FACILITATE ENDOSCOPIC THERAPY. THE REVEAL DISTAL ATTACHMENT CAP IS INTENDED FOR GASTROINTESTINAL MUCOSAL RESECTION (ENDOSCOPIC MUCOSAL RESECTION) AND FOR KEEPING THE SUITABLE DEPTH OF ENDOSCOPE'S VIEW FIELD. THE USER REPORTED THE REVEAL DISTAL ATTACHMENT CAP BECAME DETACHED FROM THE ENDOSCOPE DURING A PROCEDURE IN THE DUODENUM. THE REVEAL DISTAL ATTACHMENT CAP WAS IMMEDIATELY REMOVED WITH A RETRIEVAL DEVICE, WITH NO HARM TO THE PATIENT AS A RESULT OF THE DEVICE DETACHMENT OR DEVICE REMOVAL. IN FOLLOW UP COMMUNICATION, US ENDOSCOPY LEARNED THE USER DID NOT SECURE THE DEVICE TO THE ENDOSCOPE WITH MEDICAL GRADE TAPE, AS DIRECTED IN THE INSTRUCTIONS FOR USE (IFU). ADDITIONAL INFORMATION FOUND IN THE IFU DIRECTS THE USER TO VERIFY THE OUTER DIAMETER OF THE ENDOSCOPE IS COMPATIBLE WITH THE INNER DIAMETER OF THE DEVICE, AND DIRECTS THE USER TO ENSURE THE DEVICE AND THE TIP OF THE ENDOSCOPE ARE DRY AND FREE OF LUBRICANTS, OILS, ALCOHOL, OR XYLOCAINE SPRAY, PRIOR TO ATTACHMENT OF THE DEVICE. THE USER HAS BEEN INFORMED OF THE ATTACHMENT DIRECTIONS FOUND IN THE INSTRUCTIONS FOR USE. A REVIEW OF THE MANUFACTURING RECORD FOUND NO ANOMALIES NOTED DURING MANUFACTURE AND FOUND TESTS AND INSPECTIONS WERE PERFORMED WITH ACCEPTABLE RESULTS DOCUMENTED. THIS REPORT WILL BE UPDATED IF ADDITIONAL INFORMATION BECOMES AVAILABLE.
THE REVEAL DISTAL ATTACHMENT CAP HAS BEEN DESIGNED TO BE ATTACHED TO THE DISTAL END OF THE ENDOSCOPE TO FACILITATE ENDOSCOPIC THERAPY. THE REVEAL DISTAL ATTACHMENT CAP IS INTENDED FOR GASTROINTESTINAL MUCOSAL RESECTION (ENDOSCOPIC MUCOSAL RESECTION) AND FOR KEEPING THE SUITABLE DEPTH OF ENDOSCOPE'S VIEW FIELD. THE USER REPORTED THE REVEAL DISTAL ATTACHMENT CAP BECAME DETACHED FROM THE ENDOSCOPE DURING A PROCEDURE IN THE DUODENUM. THE REVEAL DISTAL ATTACHMENT CAP WAS IMMEDIATELY REMOVED WITH A RETRIEVAL DEVICE, WITH NO HARM TO THE PATIENT AS A RESULT OF THE DEVICE DETACHMENT OR DEVICE REMOVAL.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 615455 | REVEAL DISTAL ATTACHMENT CAP | DISTAL ATTACHMENT CAP | OCX | UNITED STATES ENDOSCOPY GROUP, INC. | 00711772 | 1503800 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |