FDA Adverse Event Malfunction Summary report: N

ARCHITECT HBSAG

MDR report key: 5046522 · Received September 1, 2015

Report

Report Number
3008344661-2015-00023
Event Type
Malfunction
Date Received
September 1, 2015
Date of Event
May 27, 2015
Report Date
October 6, 2015
Manufacturer
ABBOTT IRELAND
Product Code
KSJ
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FR
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). AN EVALUATION IS IN PROCESS. A FOLLOW-UP REPORT WILL BE SUBMITTED WHEN THE EVALUATION IS COMPLETE. THIS REPORT IS BEING FILED ON AN INTERNATIONAL PRODUCT, LIST NUMBER 6C36 THAT HAS A SIMILAR PRODUCT DISTRIBUTED IN THE US, LIST NUMBER 1L80 AND 4P53.

Additional Manufacturer Narrative · 1

THE CUSTOMER REPORTED POTENTIALLY (B)(6) FOR A PATIENT SAMPLE TESTED WITH ARCHITECT HBSAG QUANTITATIVE ASSAY LIST 6C36-41, LOT UNKNOWN. (B)(6) WERE ALSO GENERATED ON THE ARCHITECT HBSAG QUALITATIVE II ASSAY, 2G22-25 LOT 49406LF00. NO PATIENT SAMPLE WAS AVAILABLE FOR RETURN. CUSTOMER COMPLAINT DATA WAS REVIEWED AND NO ADVERSE OR NON-STATISTICAL TRENDS WERE IDENTIFIED. THE ARCHITECT HBSAG QUANTITATIVE ASSAY REAGENT PACKAGE INSERT WAS REVIEWED AND WAS FOUND TO ADEQUATELY ADDRESS THE ISSUE. ADDITIONAL INFORMATION PROVIDED BY ABBOTT MEDICAL AFFAIRS: A GROUP OF PATIENTS WITH (B)(6) HAS BEEN IDENTIFIED BY SENSITIVE, MOLECULAR TESTING FOR (B)(6). MEMBERS OF THIS GROUP ARE OFTEN REFERRED TO AS HAVING (B)(6) WHICH IS DIAGNOSED WHEN AN (B)(6) IS UNDETECTABLE. (B)(6) OCCURS IN A NUMBER OF CLINICAL SETTINGS AND MAY REPRESENT ACUTE INFECTION IN THE WINDOW PERIOD, (B)(6), PERSISTENCE OF REPLICATION AT LOW LEVEL AFTER RECOVERY IN THE PRESENCE OF (B)(6), OR OCCURRENCE OF AN ESCAPE MUTANT IN VACCINATED OR UNVACCINATED INDIVIDUALS NOT DETECTED BY CURRENT (B)(6) ASSAYS H. W. REESINK ET AL. (B)(6) IN BLOOD DONORS. VOX SANGUINIS (2008) 94 , 153-166 MICHAEL TORBENSON AND DAVID L THOMAS. OCCULT HEPATITIS B. LANCET INFECT DIS 2002; 2: 479-86 THE INVESTIGATION DID NOT IDENTIFY A MALFUNCTION / DEFICIENCY.

Description of Event or Problem · 1

THE CUSTOMER WAS QUESTIONING POSSIBLE (B)(6) ARCHITECT (B)(6) RESULTS. THE PATIENT HAD (B)(6) 2 YEARS AGO. ARCHITECT HBSAG AND ARCHITECT HBSAG QUALITATIVE II WERE (B)(6). PCR TESTING WAS (B)(6) FOR (B)(6) (54 IU/ML). THERE WAS NO REPORT OF IMPACT TO PATIENT MANAGEMENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
579405 ARCHITECT HBSAG HBSAG KSJ ABBOTT IRELAND

Patients

Seq Age Sex Outcome Treatment
1