QUICK-CROSS SUPPORT CATHETER
Report
- Report Number
- 5044576
- Event Type
- Malfunction
- Date Received
- September 1, 2015
- Date of Event
- August 11, 2015
- Report Date
- August 28, 2015
- Manufacturer
- SPECTRANETICS CORP
- Product Code
- DQY
- Adverse Event
- Yes
- Report Source
- User Facility report
- Reporter Location
- CT, US
- Reporter Occupation
- OTHER
Narratives
THE TIP OF THE QUICK CROSS CATHETER BROKE OFF IN RIGHT FEM POP BYPASS GRAFT. AN OPEN EXPLORATION WAS PERFORMED AND THE TIP WAS SUCCESSFULLY RETRIEVED. THE SURGEON DOCUMENTED THE FOLLOWING IN HIS OPERATIVE REPORT: "... I THEN INITIALLY ATTEMPTED TO PASS A CROSS CATHETER THROUGH THIS AREA THERE IS RESISTANCE IN THE COMMON ILIAC TO EXTERNAL ILIAC ARTERY STENT JUNCTION. WIRE EXCHANGES WERE MADE FOR A MAGIC TORQUE WIRE WHICH WAS ADVANCED THROUGH THIS REGION AND DOWN TO THE LEVEL OF THE OCCLUDED FEMORAL-POPLITEAL BYPASS GRAFT. THREE THOUSAND UNITS OF INTRAVENOUS HEPARIN WERE GIVEN AS A BOLUS AT THIS TIME. I WAS ABLE TO ADVANCE A 6 FRENCH ANSEL INTRODUCER SHEATH OVER THE AORTIC BIFURCATION AND PLACED IN THE PROXIMAL RIGHT COMMON ILIAC ARTERY STENT. I THEN ADVANCED A Q-QUICK CROSS CATHETER OVER THE MAGIC TORQUE WIRE AND THE COMBINATION OF QUICK CROSS AND MAGIC TORQUE WIRE IN ADVANCED FULL LENGTH THROUGH THE FEMORAL-POPLITEAL BYPASS GRAFT WHICH HAD BEEN NOTED TO COMPLETELY OCCLUDED DOWN TO THE LEVEL OF THE PREVIOUSLY PLACED STENTS IN THE REGION OF THE DISTAL BYPASS GRAFT STENOSIS. I WAS ABLE TO ADVANCE THE WIRE PAST THE STENTED REGION BUT NOT INTO THE NATIVE POPLITEAL ARTERY THE CATHETER WAS ADVANCED DOWN TO THIS REGION ALSO. THROUGH THE CATHETER A STIFF AND SOFT ANGLED GLIDEWIRE WERE PASSED IN ATTEMPTS WERE MADE TO CROSS THE OCCLUDED POPLITEAL ARTERY WITH THIS WAS UNSUCCESSFUL. I THEN ATTEMPTED TO WITHDRAW THE QUICK CROSS CATHETER WITH THE INITIAL PLANS TO ANGIOPLASTY THE ILIAC ARTERY AND STENOSES, ADVANCED THE 6 FRENCH SHEATH DOWN TO THE COMMON FEMORAL ARTERY FOR IMPROVED SUPPORT AND ATTEMPT TO CROSS THE OCCLUDED DISTAL ASPECT OF THE FEMOROPOPLITEAL BYPASS GRAFT. CATHETER AND GUIDEWIRE COMBINATION WOULD NOT RELEASE. ATTEMPTS TO MANIPULATE THE CATHETER OVER THE MAGIC TORQUE WIRE WERE UNSUCCESSFUL. I THEN DECIDED TO WITHDRAW BOTH CATHETER AND GUIDEWIRE AT THE SAME TIME THERE WAS AN ABRUPT RELEASE OF THE CATHETER AND UNDER FLUOROSCOPY THE DISTAL ASPECT OF THE CATHETER WAS SEEN TO BE LODGED IN THE STENTED REGION OF THE FEMOROPOPLITEAL BYPASS GRAFT AND THE REMAINDER OF THE CATHETER AND MAGIC TORQUE WIRE WERE RETRIEVED. THE 6 FRENCH SHEATH WAS LEFT IN THE POSITION NOTED. IN THE DECISION WAS MADE TO OPEN THE RIGHT THIGH..."
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 577903 | QUICK-CROSS SUPPORT CATHETER | CATHETER, PERCUTANEOUS | DQY | SPECTRANETICS CORP | FQQ15EOA |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 65 YR |