FDA Adverse Event Injury Summary report: N

PLATE, FIXATION, BONE

MDR report key: 5018776 · Received August 20, 2015

Report

Report Number
2520274-2015-15315
Event Type
Injury
Date Received
August 20, 2015
Report Date
August 17, 2015
Manufacturer
SYNTHES USA
Product Code
HRS
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
PA, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

DEVICE USED FOR TREATMENT, NOT FOR DIAGNOSIS. IHN, J, ET, AL (2008) ANTERIOR PLATING AND PERCUTANEOUS ILIOSACRAL SCREWING IN AN UNSTABLE PELVIC RING INJURY, J ORTHOP SCI, 13:107-115. THIS REPORT IS FOR AN UNKNOWN PLATE (UNKNOWN QUANTITY/UNKNOWN LOT). ONE PATIENT HAD MILD RESIDUAL SENSORY SYMPTOMS. THE INVESTIGATION COULD NOT BE COMPLETED; NO CONCLUSION COULD BE DRAWN, AS NO DEVICE WAS RETURNED AND NO LOT NUMBER OR PART NUMBER WAS PROVIDED. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

THIS REPORT IS BEING FILED AFTER SUBSEQUENT REVIEW OF THE FOLLOWING LITERATURE ARTICLE: O,H; KIM, P; KIM, J; MIN, W; KYUUNG, H; ETAL (2008) ANTERIOR PLATING AND PERCUTANEOUS ILIOSACRAL SCREWING IN AN UNSTABLE PELVIC RING INJURY, J OPRTHOP SCI, 13:107-115. IN THIS RETROSPECTIVE STUDY, THE EFFECTIVENESS OF ANTERIOR PLATING WITH SUBSEQUENT PERCUTANEOUS ILIOSACRAL SCREWING FOR THE MANAGEMENT OF UNSTABLE PELVIC RING INJURIES IN 81 PATIENTS WERE EVALUATED. TWENTY-THREE OF THESE WERE TREATED WITH ANTERIOR PLATING AND A PERCUTANEOUS ILIOSACRAL SCREW FIXATION. OF THESE, 19 PATIENTS WERE FOLLOWED UP FOR 1 YEAR (8 MEN AND 11 WOMEN) FROM 1999 TO 2005. THE ANTERIOR RING WITH A SINGLE PELVIC RECONSTRUCTION PLATE (3.5 MM, SYNTHES, SWITZERLAND) WAS USED, UNLESS THE FRACTURES WERE LOCATED AROUND THE SYMPHYSIS PUBIS OR WERE NOT SEVERE ENOUGH TO HAVE THREE SCREWS IN EACH SEGMENT. REGARDING COMPLICATIONS, THERE WAS ONE DEEP INFECTION ON THE ANTERIOR FIXATION AREA. AFTER REMOVING THE ANTERIOR PLATE AND DEBRIDEMENT, THIS HEALED WITHOUT FURTHER DISPLACEMENT OF THE FRACTURES. METAL FAILURES OCCURRED IN 4 PATIENTS, ONE WITH TYPE-B AND THREE WITH TYPE-C FRACTURES. TWO FAILURES OCCURRED IN THE ANTERIOR PLATE, ONE WAS A PLATE BREAKAGE WITH NONUNION, SINCE IT WAS ASYMPTOMATIC, NO FURTHER PROCEDURE WAS CARRIED OUT; AND ONE WAS THE LOOSENING OF SCREWS. TWO OF THESE HAD PAIN DUE TO S1-S3 NERVE INJURIES, DYSTHESIA, AND A LIMITATION OF MOTION, AND THE OTHER ONE HAD MILD RESIDUAL SENSORY SYMPTOMS ONLY. ONE PATIENT HAD AN ANTERIOR SCREW BREAKAGE. A COPY OF THE LITERATURE ARTICLE IS BEING SUBMITTED WITH THIS MEDWATCH. THIS REPORT IS 3 OF 3 FOR (B)(4). THIS REPORT IS FOR AN UNKNOWN PLATE. TWO UNKNOWN PATIENTS, EXPERIENCED SERIOUS INJURIES, PAIN, NERVE INJURY, DYSTHESIA, LIMITATION OF MOTION, AND THE OTHER ONE HAD MILD RESIDUAL SENSORY SYMPTOMS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
552371 PLATE, FIXATION, BONE HRS SYNTHES USA

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention