FDA Adverse Event Injury Summary report: N

SMR METAL-BACK (TI6AL4V + POROTI) METAL-BACK SMALL-R

MDR report key: 4952913 · Received July 30, 2015

Report

Report Number
3008021110-2015-00031
Event Type
Injury
Date Received
July 30, 2015
Date of Event
June 25, 2015
Report Date
July 1, 2015
Manufacturer
LIMACORPORATE S.P.A.
Product Code
KWS
PMA / PMN Number
K113254
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

BY EVENT DESCRIPTION, NO MECHANICAL FAILURE OF THE PROSTHESIS (METAL BACK AND GLENOSPHERE WERE WELL FIXED ONE EACH OTHER WHEN CAME LOOSE FROM GLENOID BONE). THIS HAS BEEN CONFIRMED BY A RADIOLOGIC EVALUATION AND BY SOME PHOTOS OF THE EXPLANTS RETURNED. EXPLANTS NOT RETURNED. NO ANOMALIES DETECTED BY CHECKING THE DHR OF THE METAL BACK AND GLENOSPHERE INVOLVED. NO OTHER COMPLAINTS RECEIVED ON THESE LOT # (METAL BACK: (B)(4) PIECES MANUFACTURED; GLENOSPHERE: (B)(4) PIECES MANUFACTURED). ADDITIONAL FINDINGS BY X-RAYS EVALUATION: IN THE X-RAY DATED (B)(6) 2015 (IMMEDIATE POST-OP), WHOLE CONSTRUCT OF MB + GLENOSPHERE APPEARS TO BE ALREADY PARTIALLY OUT OF THE GLENOID BONE (IN THE SUPERIOR PART); THIS SUGGESTS A SUBOPTIMAL IMPLANT TECHNIQUE. THE X-RAY DATED (B)(6) 2015 SHOWS THAT THE WHOLE CONSTRUCT COMPLETELY CAME OUT FROM THE BONE. PROBABLE CAUSE OF THE INCIDENT: SUBOPTIMAL IMPLANTATION TECHNIQUE, MAYBE COMBINED WITH INADEQUATE BONE SUPPORT TO SUSTAIN THE LOADS OF THE SYSTEM MB + GLENOSPHERE. AS REPORTED BY SMR SURGICAL TECHNIQUE: "THE BONE STOCK OF THE GLENOID AND HUMERUS MUST BE ABLE TO SUPPORT THE IMPLANT. IN CASES WITH SIGNIFICANT BONE LOSS AND IN WHICH ADEQUATE FIXATION ON THE GLENOID SIDE CANNOT BE OBTAINED, A HEMI WITH CTA HEAD SHOULD BE PERFORMED." PMS DATA: REVISION RATE ASSOCIATED TO THIS EVENT IS 0.034%; THE MAJORITY OF SIMILAR EVENTS WAS DUE TO IMPROPER IMPLANTATION OR PATIENT TRAUMA / BONE CONDITION. NO CORRECTIVE ACTIONS. (B)(4) CORPORATE WILL KEEP THE MARKET MONITORED TO PROMPTLY DETECT POSSIBLE RECURRENCE OF SUCH EVENT. DEVICE NOT RETURNED.

Description of Event or Problem · 1

SMR REVERSE IMPLANTED ON (B)(6) 2015. REVISION SURGERY ON (B)(6) 2015 DUE TO METAL BACK + GLENOSPHERE COMING OFF (AS A SINGLE PIECE) FROM THE GLENOID BONE. SURGEON REPLACED THE WHOLE PROSTHESIS. THE EVENT OCCURRED IN (B)(6).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
497227 SMR METAL-BACK (TI6AL4V + POROTI) METAL-BACK SMALL-R KWS KWS LIMACORPORATE S.P.A. 1375.21.005 201407833

Patients

Seq Age Sex Outcome Treatment
1 74 YR Required Intervention