FDA Adverse Event Injury Summary report: N

M2A-MAGNUM MOD HD SZ 50MM

MDR report key: 4932931 · Received July 22, 2015

Report

Report Number
0001825034-2015-03206
Event Type
Injury
Date Received
July 22, 2015
Date of Event
August 29, 2014
Report Date
August 22, 2019
Manufacturer
BIOMET ORTHOPEDICS
Product Code
KWA
PMA / PMN Number
PK042037
Removal / Correction Number
N/A
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NE, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

CURRENT INFORMATION IS INSUFFICIENT TO PERMIT A CONCLUSION AS TO THE CAUSE OF THE EVENT. REVIEW OF DEVICE HISTORY RECORDS SHOW THAT LOT RELEASED WITH NO RECORDED ANOMALY OR DEVIATION. THERE ARE WARNINGS IN THE PACKAGE INSERT THAT STATE THAT THIS TYPE OF EVENT CAN OCCUR: "INTRAOPERATIVE OR POSTOPERATIVE BONE FRACTURE AND/OR POSTOPERATIVE PAIN." AND "INADEQUATE RANGE OF MOTION DUE TO IMPROPER SELECTION OR POSITIONING OF COMPONENTS." THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF¿S COMPLAINT, AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED.

Additional Manufacturer Narrative · 1

THIS FOLLOW-UP REPORT IS BEING FILED TO RELAY CORRECTED INFORMATION AND ADDITIONAL INFORMATION, WHICH WAS UNKNOWN AT THE TIME OF THE INITIAL MEDWATCH. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF¿S COMPLAINT, AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. THIS REPORT IS NUMBER 1 OF 2 MDRS FILED FOR THE SAME EVENT (REFERENCE 1825034-2015-03206-1 / 04445).

Description of Event or Problem · 1

LEGAL COUNSEL FOR PATIENT REPORTED PATIENT UNDERWENT LEFT TOTAL HIP ARTHROPLASTY ON (B)(6) 2011. SUBSEQUENTLY, PATIENT'S LEGAL COUNSEL FURTHER REPORTED PATIENT UNDERWENT A REVISION PROCEDURE ON (B)(6) 2014 DUE TO PATIENT ALLEGATIONS OF PAIN, INFLAMMATION, BURSITIS, TISSUE DETERIORATION, AND LIMITED MOBILITY. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF'S COMPLAINT, AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED.

Description of Event or Problem · 1

LEGAL COUNSEL FOR PATIENT REPORTED PATIENT UNDERWENT LEFT TOTAL HIP ARTHROPLASTY ON (B)(6) 2011. SUBSEQUENTLY, PATIENT'S LEGAL COUNSEL FURTHER REPORTED PATIENT UNDERWENT A REVISION PROCEDURE ON (B)(6) 2014 DUE TO PATIENT ALLEGATIONS OF PAIN, INFLAMMATION, BURSITIS, TISSUE DETERIORATION, AND LIMITED MOBILITY. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF'S COMPLAINT, AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. ADDITIONAL INFORMATION RECEIVED IN PATIENT'S OPERATIVE REPORT INDICATES THAT THE REVISION PROCEDURE THAT TOOK PLACE ON (B)(6) 2014 NOTED EFFUSION DUE TO METAL DEBRIS DURING THE REVISION PROCEDURE. OPERATIVE REPORT ALSO NOTED THE REVISION OF THE ACETABULAR CUP DUE TO MINIMAL BONE INGROWTH.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
475733 M2A-MAGNUM MOD HD SZ 50MM PROSTHESIS, HIP KWA BIOMET ORTHOPEDICS N/A 527080

Patients

Seq Age Sex Outcome Treatment
1 67 YR Hospitalization| R