FDA Adverse Event Malfunction Summary report: N

NSK SGA -E2S

MDR report key: 4926335 · Received July 17, 2015

Report

Report Number
9611253-2015-00099
Event Type
Malfunction
Date Received
July 17, 2015
Report Date
July 13, 2015
Manufacturer
NAKANISHI, INC. (NSK)
Product Code
KMW
PMA / PMN Number
K970953
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
GA, US
Reporter Occupation
DENTIST

Narratives

Additional Manufacturer Narrative · 1

UPON RECEIPT FROM THE DENTIST OF THE DEVICE INVOLVED IN THE MDR EVENT, NAKANISHI CONDUCTED A FAILURE ANALYSIS OF THE RETURNED DEVICE THAT INCLUDED AN ATTEMPT TO MEASURE THE TEMPERATURE OF THE OPERATING DEVICE. THESE ACTIVITIES ARE DESCRIBED IN MORE DETAIL BELOW. METHODOLOGY USED: AS AN INVESTIGATION APPROACH NAKANISHI INC., (B)(4)(MANUFACTURER) EXAMINED THE DHR FOR DEVICE (SGA-E2S, SERIAL NO (B)(4)). THERE WERE NO PROBLEMS OBSERVED DURING THE MANUFACTURING OR TESTING NOTED IN THE DHR; NAKANISHI CONDUCTED A VISUAL INSPECTION OF THE RETURNED DEVICE AND PERFORMED A SIMPLE MOVEMENT TEST. THERE WERE NO VISIBLE ABNORMALITIES, SUCH AS CRACKS OR DEBRIS, ON THE OUTSIDE OF THE HANDPIECE. NAKANISHI THEN SET A TEST BUR IN THE HANDPIECE AND ROTATED IT BY HAND. NAKANISHI OBSERVED THAT THE BUR DID NOT ROTATE SMOOTHLY; NAKANISHI MEASURED THE TEMPERATURE OF THE HANDPIECE. NAKANISHI ATTACHED A THERMOCOUPLE (SENSOR TO MEASURE A TEMPERATURE) TO FOUR TESTING POINTS. NAKANISHI TOOK PHOTOGRAPHS OF THE CONFIGURATION OF THE TEMPERATURE MEASUREMENT TEST. NAKANISHI ROTATED THE HANDPIECE AT 40,000 RPM WHICH IS MAXIMUM RPM FOR THE MOTOR THAT DRIVES THE HANDPIECE WITHOUT WATER SPRAY AND MEASURED THE EXOTHERMIC SITUATION. THE TEMPERATURE REACHED 72.7 DEGREES C, 61.6 DEGREES C, 33.1 DEGREES C AND 30.5 DEGREES C RESPECTIVELY, 69 SECONDS AFTER THE BEGINNING OF THE TEST. NAKANISHI CREATED CHARTS USING THE DATA FOR ANALYSIS. IDENTIFICATION OF A SPECIFIC FAILURE MODE(S) AND/OR MECHANISM(S) AND THE ASSOCIATED DEVICE COMPONENTS INVOLVED NAKANISHI DISASSEMBLED THE HANDPIECE AND PERFORMED A VISUAL INSPECTION OF THE INSIDE PARTS. NAKANISHI OBSERVED BUILDUP OF SHAVINGS FROM WORN BALL BEARING RETAINER INSIDE THE HEAD CAP AND THE CARTRIDGE (HEAD CAP SIDE). NAKANISHI REASSEMBLED AND WASHED THE HANDPIECE USING NAKANISHI PANA-SPRAY PER THE INSTRUCTION INCLUDED IN THE USER MANUAL. NAKANISHI OBSERVED DIRT/DEBRIS EXPELLED FROM THE HEAD OF THE HANDPIECE BY USING A WHITE FILTER TO CATCH ANYTHING THAT WAS EXPELLED. NAKANISHI TOOK PHOTOGRAPHS OF THE EXPELLED DIRT/DEBRIS. NAKANISHI BELIEVES THAT OVERHEATING WAS CAUSED BY THE WEAR OF BEARING RETAINER. THE DIRT/DEBRIS ACCUMULATED INSIDE THE BEARING RETAINER INCREASED THE REAR BEARING LOAD AND CAUSED EXCESS HEAT GENERATION. CONCLUSIONS REACHED BASED ON THE INVESTIGATION AND ANALYSIS RESULTS: NAKANISHI IDENTIFIED THAT THE CAUSE OF OVERHEATING OF THE RETURNED DEVICE WAS DUE TO DAMAGE OF THE BEARING RETAINER THAT WAS CAUSED BY ACCUMULATED DIRT/DEBRIS. THE DAMAGE OBSERVED CAUSED ABNORMAL ROTATIONAL RESISTANCE, WHICH WOULD RESULT IN THE HANDPIECE OVERHEATING.

Additional Manufacturer Narrative · 1

NAKANISHI IS NOW INVESTIGATING THIS EVENT AND WILL SUBMIT ADDITIONAL INFORMATION INCLUDING RESULTS OBTAINED THROUGH THE INVESTIGATION AS FOLLOW-UP REPORT.

Description of Event or Problem · 1

THE FOLLOWING INFORMATION IS FROM NSK AMERICA CORP. TO NAKANISHI INC. (NSK), REGARDING A DEVICE MANUFACTURED BY NSK. EVENT SUMMARY: ON JUNE 4, NSK AMERICA RECEIVED A HANDPIECE (MODEL SGA-E2S SERIAL (B)(4)) FROM DEALER FOR REPAIR. INCOMING COMMENTS STATED "OVER HEATING. BURNT PATIENT LIP". IMMEDIATELY NSK AMERICA CONTACTED DEALER FOR DENTIST INFORMATION. NSK AMERICA CONTACTED OFFICE MANAGER AT DR. OFFICE, RECEIVED CALL BACK FROM MANAGER. DURING CONVERSATION IT WAS STATED THE DENTIST HAD BURNED THE PATIENT WITH THE HANDPIECE. NO INFORMATION PROVIDED ON PATIENT OR DATE OF THE EVENT. NSK AMERICA ATTEMPTED CONTACT BY TELEPHONE AND E-MAIL ON 06/08/2015 AND 06/10/2015 NO RESPONSE AND FURTHER FOLLOW-UPS WITH NO RESPONSE. NSK AMERICA REPLACED AND FORWARDED THIS HANDPIECE TO NHQ FOR FULL EVALUATION ON 06/17/2015.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
465413 NSK SGA -E2S HANDPIECE, ROTARY BONE CUTTING KMW NAKANISHI, INC. (NSK) SGA-E2S

Patients

Seq Age Sex Outcome Treatment
1