VALIANT CAPTIVIA
Report
- Report Number
- 2953200-2015-01052
- Event Type
- Injury
- Date Received
- July 17, 2015
- Date of Event
- May 19, 2015
- Report Date
- June 25, 2015
- Manufacturer
- MEDTRONIC IRELAND
- Product Code
- MIH
- PMA / PMN Number
- P100040
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CH
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4)
EARLY RESULTS OF CHIMNEY TECHNIQUE FOR TYPE B AORTIC DISSECTIONS EXTENDING TO THE AORTIC ARCH CHEN HUAN, HANFEI TANG, TONG QUAO, CH ANGJIAN LIU, MIN ZHOU, CARDIOVASC INTERVENT RADIOL; 2015 1145-9 VALIANT STENT GRAFT SYSTEMS WERE IMPLANTED IN THE PATIENT FOR THE ENDOVASCULAR TREATMENT OF TYPE B THORACIC AORTIC DISSECTIONS. THE FOLLOWING ADVERSE EVENTS WERE OBSERVED: TYPE I ENDOLEAK. ABSTRACT OBJECTIVE: TO SUMMARIZE OUR EARLY EXPERIENCE GAINED FROM THE CHIMNEY TECHNIQUE FOR TYPE B AORTIC DISSECTION (TBAD) EXTENDING TO THE AORTIC ARCH AND TO EVALUATE THE AORTIC REMODELING IN THE FOLLOW-UP PERIOD. METHODS: FROM SEPTEMBER 2011 TO JULY 2014, 27 CONSECUTIVE TBAD PATIENTS WITHOUT ADEQUATE PROXIMAL LANDING ZONES WERE RETROGRADE ANALYZED. CHIMNEY STENT-GRAFTS WERE DEPLOYED PARALLEL TO THE MAIN ENDOGRAFTS TO RESERVE FLOW TO BRANCH VESSELS WHILE EXTENDING THE LANDING ZONES. IN THE FOLLOW-UP PERIOD, AORTIC REMODELING WAS OBSERVED WITH COMPUTED TOMOGRAPHY ANGIOGRAPHY. RESULTS: THE TECHNICAL SUCCESS RATE WAS 100 %, AND ENDOGRAFTS WERE DEPLOYED IN ZONE 0 (N = 3, 11.1 %), ZONE 1 (N = 18, 66.7 %), AND ZONE 2 (N = 6, 22.2 %). IMMEDIATELY, PROXIMAL ENDOLEAKS WERE DETECTED IN 5 PATIENTS (18.5 %). DURING A MEAN FOLLOW-UP PERIOD OF 17.6 MONTHS, COMPUTED TOMOGRAPHY ANGIOGRAPHY SHOWED ALL THE AORTIC STENT-GRAFTS AND CHIMNEY GRAFTS TO BE PATENT. FAVORABLE REMODELING WAS OBSERVED AT THE LEVEL OF MAXIMUM DESCENDING AORTA AND LEFT SUBCLAVIAN ARTERY WITH EXPANSION OF TRUE LUMEN (FROM 18.4 ± 4.8 TO 25 ± 0.86 MM, P\0.001 AND 27.1 ± 0.62 TO 28.5 ± 0.37 MM, P\0.001) AND DEPRESSURIZATION OF FALSE LUMEN (FROM 23.7 ± 2.7 TO 8.7 ± 3.8 MM, P\0.001, FROM 5.3 ± 1.2 TO 2.1 ± 2.1 MM, P\0.001). WHILE AT THE LEVEL OF MAXIMUM ABDOMINAL AORTA, SUBOPTIMAL REMODELING OF THE TOTAL AORTA (FROM 24.1 ± 0.4 TO 23.6 ± 1.5 MM, P = 0.06) AND TRUE LUMEN (FROM 13.8 ± 0.6 TO 14.5 ± 0.4 MM, P = 0.08) WAS OBSERVED. CONCLUSION: BASED ON OUR LIMITED EXPERIENCE, THE CHIMNEY TECHNIQUE WITH THORACIC ENDOVASCULAR REPAIR IS DEMONSTRATED TO BE PROMISING FOR TBAD EXTENDING TO THE ARCH WITH FAVORABLE AORTIC REMODELING.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 466617 | VALIANT CAPTIVIA | SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT | MIH | MEDTRONIC IRELAND |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00073 YR | Required Intervention |