UNKNOWN IMPLANTABLE NEUROSTIMULATOR
Report
- Report Number
- 3007566237-2015-01833
- Event Type
- Death
- Date Received
- July 1, 2015
- Date of Event
- March 26, 2015
- Report Date
- June 3, 2015
- Manufacturer
- MEDTRONIC NEUROMODULATION
- Product Code
- MHY
- PMA / PMN Number
- P960009
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GM
- Reporter Occupation
- HEALTH PROFESSIONAL
Narratives
PLEASE NOTE THAT THESE DATES ARE BASED OFF OF THE DATE THAT THE ARTICLE WAS ACCEPTED FOR PUBLICATION AS THE EVENT DATE AND DATE OF DEATH WERE NOT PROVIDED IN THE PUBLISHED LITERATURE. IT WAS NOT POSSIBLE TO ASCERTAIN SPECIFIC DEVICE INFORMATION FROM THE ARTICLE OR TO MATCH THE EVENTS REPORTED WITH PREVIOUSLY REPORTED EVENTS. CORRESPONDENCE HAS BEEN SENT TO THE AUTHOR OF THE ARTICLE INQUIRING ABOUT INDIVIDUAL PATIENT INFORMATION AND ADDITIONAL INFORMATION REGARDING THE REPORTED EVENTS. PRODUCT ID 3387 LOT# UNKNOWN; PRODUCT TYPE LEAD. (B)(4).
KRONENBUERGER, M., NOLTE, K.W., COENEN, V.A., BURGUNDER, J.M., KRAUSS, J.K., WEIS, J. BRAIN ALTERATIONS WITH DEEP BRAIN STIMULATION: NEW INSIGHT FROM A NEUROPATHOLOGICAL CASE SERIES. MOVEMENT DISORDERS : OFFICIAL JOURNAL OF THE MOVEMENT DISORDER SOCIETY. 2015. DOI: 10.1002/MDS.26247 SUMMARY: PREVIOUS STUDIES ON HUMAN BRAIN TISSUE ALTERATIONS CAUSED BY DEEP BRAIN STIMULATION DESCRIBED GLIAL AND REACTIVE INFLAMMATORY CHANGES. IN THE CURRENT PATHOANATOMICAL STUDY, WE EXTENDED THE ANALYSIS TO SIGNS OF AXONAL CHANGES AND THE INFLUENCE OF CONCOMITANT DISEASE. BRAINS OF 10 PATIENTS WITH PARKINSON¿S DISEASE OR ESSENTIAL TREMOR AND A TOTAL OF 18 ELECTRODES WERE SYSTEMATICALLY EXAMINED UP TO 7.5 Y AFTER SURGERY. IN GENERAL, TISSUE THAT HAD LONG-TERM CONTACT WITH THE ELECTRODE MATERIAL EXHIBITED ASTROGLIOSIS IN ALL, T-LYMPHOCYTES IN 93%, AND MULTINUCLEATED GIANT CELLS IN 68% OF PATIENTS. IMMUNOHISTOCHEMISTRY SHOWED ANINCREASE IN AMYLOID PRECURSOR PROTEIN IMMUNOREACTIVE AXONAL SWELLINGS IN THE BRAIN AT THE ELECTRICALLY ACTIVE PARTS OF THE ELECTRODES. PATIENTS WHO DIED OF SEPTICEMIA SHOWED A MORE SEVRE ASTROGLIOSIS AND GIANT CELL REACTION THAN PATIENTS WHO DIED OF CARDIOVASCULAR EVENTS. PARKINSON¿S DISEASE OR ESSENTIAL TREMOR DID NOT DIFFERENTIALLY PRODUCE HISTOPATHOLOGICAL CHANGES AROUND THE ELECTRODES. LONG-TERM ELECTRICAL STIMULATION BY DEEP BRAIN STIMULATION CAUSES MINOR AXONAL CHANGES. THE CAUSE OF DEATH, BUT NOT THE UNDERLYING NEUROLOGICAL DISEASE, AFFECTS THE HISTOPATHOLOGICAL CHANGES AROUND THE ELECTRODE. THE FINDINGS NEED TO BE REPRODUCED BY EXAMINING LARGER PATIENT SUBGROUPS. REPORTED EVENTS: PATIENT 8: ONE (B)(6) FEMALE PATIENT WITH BILATERAL VENTRAL INTERMEDIAL NUCLEUS (VIM) DEEP BRAIN STIMULATION (DBS) FOR ESSENTIAL TREMOR DIED 15 MONTHS AFTER IMPLANT DUE TO INFECTIOUS DISEASE AND SUBSEQUENT SEPSIS. THE PATIENT REPORTEDLY SHOWED SEVERE ASTROGLISOSIS AND GIANT CELL REACTION. ASTROGLISOSIS, MULTI-NUCLEATED GIANT CELLS (MGNC), LYMPHOCYTES, AND GRANULOCYTES WERE MORE PROMINENT AROUND THE DEEP BRAIN STIMULATION (DBS) TRACTS. THE PATIENT HAD A PROFOUND INFLAMMATORY RESPONSE AROUND THE DBS TRACTS. IT WAS NOTED THAT THE PATIENT¿S BRAIN TISSUE THAT HAD LONG-TERM CONTACT WITH THE DBS ELECTRODE MATERIAL EXHIBITED ASTROGLIOSIS AND AN INFLAMMATORY AND FOREIGN BODY REACTION (CD3-IMMUNOREACTIVE T-LYMPHOCYTES IN 93% AND MULTINUCLEATED GIANT CELLS [MNGC] IN 68% OF PATIENTS). ELEVATED COUNTS OF AMYLOID PRECURSOR PROTEIN (APP)-POSITIVE ENLARGED AXONS OR AXONAL SPHEROIDS WERE MORE PRESENT IN THE DIRECT VICINITY OF THE ACTIVE CONTACTS OF THE DBS ELECTRODES COMPARED WITH THE TISSUE AROUND THE INACTIVE CONTACTS OF THESE ELECTRODES. THE ACCUMULATION OF AXONAL DAMAGE ADJACENT TO THE ACTIVE CONTACTS OF THE DBS ELECTRODES COULD BE CLEARLY DISCERNED FROM THE BACKGROUND. A FEW DIFFUSELY SCATTERED APP-IMMUNOREACTIVE AXONS WERE SEEN. ANTI-TAU (AT8) IMMUNOSTAINING (CLONE AT8) OF SECTIONS CONTAINING THE REGIONS EXPOSED TO THE ELECTRICAL CURRENT ONLY VERY RARELY REVEALED HYPERPHOSPHORYLATED TAU IMMUNOREACTIVITY IN AXONAL STRUCTURES, INCLUDING THE AREAS ADJACENT TO THE DBS TRACT. THE SOURCE LITERATURE INCLUDED THE FOLLOWING DEVICE SPECIFICS: LEAD MODEL 3387 AND IMPLANTABLE NEUROSTIMULATOR MODEL ITREL II, SOLETRA, OR KINETRA. FURTHER INFORMATION HAS BEEN REQUESTED; A SUPPLEMENTAL REPORT WILL BE SUBMITTED IF ADDITIONAL INFORMATION IS RECEIVED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 428084 | UNKNOWN IMPLANTABLE NEUROSTIMULATOR | STIMULATOR, ELECTRICAL, IMPLANTED, FOR PARKINSONIAN TREMOR | MHY | MEDTRONIC NEUROMODULATION | NEU_INS_STIMULATOR | UNKNOWN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00082 YR | Death |