REPLACEMENT HEART VALVE
Report
- Report Number
- 2015691-2015-01567
- Event Type
- Injury
- Date Received
- June 30, 2015
- Date of Event
- June 1, 2015
- Report Date
- June 1, 2015
- Manufacturer
- EDWARDS LIFESCIENCES
- Product Code
- DYE
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CH
- Reporter Occupation
- PHYSICIAN
Narratives
METHOD: DEVICE WAS NOT RETURNED. ADDITIONAL MANUFACTURER NARRATIVE: THE DEVICE WAS NOT RETURNED TO EDWARDS FOR EVALUATION. ATTEMPTS TO RETRIEVE THE DEVICE AND ADDITIONAL INFORMATION ARE IN PROCESS. WITHOUT DEVICE RETURN OR ADDITIONAL INFORMATION THE ROOT CAUSE OF THE REPORTED EVENT IS INDETERMINABLE. IF ADDITIONAL INFORMATION IS RECEIVED A SUPPLEMENTAL MDR WILL BE SUBMITTED. EDWARDS WILL CONTINUE TO REVIEW AND MONITOR ALL EVENTS. TRENDS ARE MONITORED ON A MONTHLY BASIS AND IF ACTION IS REQUIRED, APPROPRIATE INVESTIGATION WILL BE PERFORMED.
ARTICLE: "EARLY BIOPROSTHESIS FAILURE: REPORT OF THREE CASES AND LITERATURE REVIEW PUBLISHED BY FORUM MULTIMEDIA PUBLISHING, LLC, DOI: 10.1532/HSF.1242. ABSTRACT - BACKGROUND: WE EXPERIENCED THREE RARE EARLY BIOPROSTHESIS FAILURE (EBF) CASES. IN THIS STUDY, WE ANALYZE THE CAUSES AND DISCUSS THE COPING STRATEGY OF EBF. METHODS: WE REVIEWED ALL CASES OF EBF IN PATIENTS WHO RECEIVED A BIOPROSTHESIS REPLACEMENT IN (B)(6) HOSPITAL BETWEEN (B)(6) 2001 AND (B)(6) 2014, AND REVIEWED RELATED ARTICLES THAT WERE PUBLISHED BETWEEN 1994 AND 2014, SEARCHING FOR KEYWORDS IN PUBMED SUCH AS ¿BIOPROSTHESIS,¿ ¿HEART VALVE PROSTHESIS,¿ ¿EARLY FAILURE,¿ AND ¿BIOPROSTHESIS FAILURE.¿ RESULTS: ONLY THREE CASES WERE FOUND IN (B)(6) HOSPITAL DURING THIS TIME PERIOD. THE REASONS FOR EBF IN THESE 3 CASES WERE: NATIVE VALVE ATTACHMENT, EARLY CALCIFICATION CAUSED BY METABOLIC SYNDROME, AND EARLY VALVE THROMBOSIS. LITERATURE REVIEW IDENTIFIED ADDITIONAL 14 CASES. THE REASONS FOR EBF IN THESE 14 CASES WERE AS FOLLOWS: NATIVE VALVE ATTACHMENT IN 6 CASES; METABOLIC ABNORMALITIES IN 3 CASES; EARLY VALVE THROMBOSIS IN 2 CASES; CHRONIC INFLAMMATION IN 2 CASES; AND IMPROPER OPERATION IN 1 CASE. CONCLUSION: EBF IS A RARE BUT SERIOUS COMPLICATION. THE CAUSE OF EBF IS COMPLEX. APPROPRIATE PREVENTIVE MEASURES SHOULD BE DEVELOPED ACCORDING TO THE CONDITION OF THE PATIENT. THIS REPORT IS FOR A (B)(6) FEMALE PATIENT WHO UNDERWENT RE-DO MITRAL VALVE REPLACEMENT OF HER CARPENTIER-EDWARDS VALVE AFTER AN IMPLANT DURATION OF FOUR (4) YEARS DUE TO LEAFLET ADHESION.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 421204 | REPLACEMENT HEART VALVE | DYE | EDWARDS LIFESCIENCES |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 42 YR | Hospitalization| R |