FDA Adverse Event Injury Summary report: N

NAIL, FIXATION, BONE

MDR report key: 4724467 · Received April 23, 2015

Report

Report Number
2520274-2015-13345
Event Type
Injury
Date Received
April 23, 2015
Report Date
March 31, 2015
Manufacturer
SYNTHES USA
Product Code
JDS
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
MA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. THIS REPORT IS FOR AN UNKNOWN NAIL. THE INVESTIGATION COULD NOT BE COMPLETED AND NO CONCLUSION COULD BE DRAWN AS NO DEVICE WAS RETURNED AND NO LOT NUMBER OR PART NUMBER WAS PROVIDED. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

THIS REPORT IS BEING FILED AFTER SUBSEQUENT REVIEW OF THE FOLLOWING JOURNAL ARTICLE, FERNANDES HJA, SAKAKI MH, SILVA JS, REIS FB, AND ZUMIOTTI AV. (2006). COMPARATIVE MULTICENTER STUDY OF TREATMENT OF MULTI-FRAGMENTED TIBIAL DIAPHYSEAL FRACTURES WITH NONREAMED INTERLOCKING NAILS AND WITH BRIDGING PLATES. CLINICS. 61(4):333-338. THIS WAS A PROSPECTIVE, RANDOMIZED STUDY TO COMPARE PATIENTS WITH CLOSED, MULTI-FRAGMENTED TIBIAL DIAPHYSEAL FRACTURES TREATED USING ONE OF TWO FIXATION METHODS UNDERTAKEN DURING MINIMALLY INVASIVE SURGERY: NONREAMED INTERLOCKING INTRAMEDULLARY NAILS OR BRIDGING PLATES. FORTY-FIVE PATIENTS WERE STUDIED; 22 PATIENTS WERE TREATED WITH BRIDGING PLATES, 23 WITH INTERLOCKING NAILS WITHOUT REAMING. THE STUDY PERIOD WAS FROM JANUARY 2002 TO JUNE 2003. THE FOLLOW-UP PERIOD VARIED BETWEEN 6 MONTHS TO ONE YEAR. THE BLOCKED INTRAMEDULLARY NAILS USED WERE SYNTHES AO UNIVERSAL STEEL NAILS INTRODUCED WITH NO MEDULLARY CHANNEL REAMING. THE AUTHORS USED A NARROW PLATE FOR LARGE FRAGMENTS (4.5 MM SYNTHES AO). IN THE GROUP TREATED WITH INTRAMEDULLARY NAILS, 4 PATIENTS WERE WOMEN AND 19 WERE MEN, WHILE IN THE GROUP TREATED WITH A BRIDGING PLATE, 3 WERE WOMEN AND 19 WERE MEN. THE HEALING TIME FOR PATIENTS WHO RECEIVED NAILS WAS SIGNIFICANTLY LONGER, BY AN AVERAGE OF 4.30 WEEKS, THAN THE HEALING TIME FOR THOSE WHO RECEIVED BRIDGING PLATES. FOUR PATIENTS (NUMBERS 1, 3, 7, AND 8) WHO WERE TREATED WITH INTRAMEDULLARY NAILS EXPERIENCED DELAYED HEALING. THIS REPORT IS FOR AN UNKNOWN NAIL. THIS IS REPORT 2 OF 4 FOR COMPLAINT (B)(4). THIS MEDWATCH PERTAINS TO PATIENT NUMBER 3 WHO EXPERIENCED DELAYED HEALING.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
270704 NAIL, FIXATION, BONE JDS SYNTHES USA

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention