MANUAL CONTROLLED INFANT WARMER
Report
- Report Number
- 9611451-2015-00199
- Event Type
- Malfunction
- Date Received
- April 15, 2015
- Report Date
- March 17, 2015
- Manufacturer
- FISHER & PAYKEL HEALTHCARE LTD
- Product Code
- FMT
- PMA / PMN Number
- K971461
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- UK
- Reporter Occupation
- HOSPITAL SERVICE TECHNICIAN
Narratives
(B)(4). WE ARE IN THE PROCESS OF GATHERING FURTHER INFORMATION FROM THE HOSPITAL REGARDING THE REPORTED PROBLEM. OUR INVESTIGATION IS CURRENTLY IN PROGRESS AND WE WILL PROVIDE A FOLLOW UP REPORT UPON COMPLETION OF OUR INVESTIGATION.
(B)(4). METHOD: THE COMPLAINT DEVICE WAS NOT RETURNED TO FISHER & PAYKEL HEALTHCARE (FPH) IN (B)(4) FOR EVALUATION. THEREFORE, OUR INVESTIGATION IS BASED ON THE INFORMATION PROVIDED BY THE HOSPITAL, PREVIOUS SIMILAR INVESTIGATIONS AND OUR KNOWLEDGE OF THE PRODUCT. RESULTS: THE CUSTOMER REPORTED THAT THE PIVOT SECURING NUT WAS LOOSE WHEN THE DEVICE WAS INSPECTED BY THE HOSPITAL TECHNICIAN. THEY FURTHER REPORTED THAT THE COMPLAINT DEVICE WAS PERFORMANCE CHECKED IN JANUARY 2015 WITH NO ISSUES REGARDING THE PIVOT SECURING NUT. A LOT CHECK REVEALED NO OTHER COMPLAINTS OF THIS NATURE FOR LOT 051013. CONCLUSION: THE TECHNICAL MANUAL SUPPLIED WITH THE IW990 MANUAL CONTROLLED INFANT WARMER RECOMMENDS SAFETY, PERFORMANCE AND FUNCTIONAL CHECKS TO BE CONDUCTED ON THE INFANT WARMER AT LEAST ANNUALLY. THIS INCLUDES A FUNCTIONAL CHECK OF THE WARMER'S HEATER HEAD TO ENSURE THAT IT IS SECURE, CAN BE ROTATED SMOOTHLY AND THAT THE CENTRAL DETENTE CAN BE FELT WHEN ROTATING. THE TECHNICAL MANUAL FURTHER INFORMS THE USER THAT THE PIVOT NUT CAN BE ADJUSTED OR REPLACED IF NECESSARY. IT IS UNLIKELY THAT THE PIVOT SECURING NUT BECAME LOOSE SINCE THE PERFORMANCE CHECK IN JANUARY. A LOOSE NUT SHOULD HAVE BEEN IDENTIFIED DURING THE SAFETY, PERFORMANCE AND FUNCTIONAL CHECKS. SINCE THE REPORTED EVENT AN FPH REPRESENTATIVE HAS BEEN IN CONTACT WITH THE CUSTOMER AND HAS PROVIDED ADDITIONAL INFORMATION ON TIGHTENING THE PIVOT SECURING NUT. IN ADDITION, WE ARE IN THE PROCESS OF SCHEDULING ADDITIONAL TRAINING WITH THE CUSTOMER ON THE CORRECT PERFORMANCE CHECK OF THE INFANT WARMER'S HEATER HEAD.
A HOSPITAL IN (B)(6) REPORTED THAT THE PIVOT SCREWING NUT ON AN IW990 MANUAL CONTROLLED INFANT WARMER WAS LOOSE. NO PATIENT CONSEQUENCE WAS REPORTED.
A HOSPITAL IN THE (B)(6) REPORTED THAT THE PIVOT SCREWING NUT ON AN IW990 MANUAL CONTROLLED INFANT WARMER WAS LOOSE. NO PATIENT CONSEQUENCE WAS REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 250610 | MANUAL CONTROLLED INFANT WARMER | FMT | FMT | FISHER & PAYKEL HEALTHCARE LTD | IW990 | 051013 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |