PLATE, FIXATION, BONE
Report
- Report Number
- 2520274-2015-12713
- Event Type
- Injury
- Date Received
- April 14, 2015
- Report Date
- March 27, 2015
- Manufacturer
- SYNTHES USA
- Product Code
- HRS
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- MA, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. LAFLAMME, G. ET AL (2008). PERCUTANEOUS HUMERAL PLATING OF FRACTURES OF THE PROXIMAL HUMERUS: RESULTS OF A PROSPECTIVE MULTICENTER CLINICAL TRIAL. J ORTHOP TRAUMA, 22, 153-158. THIS REPORT IS FOR AN UNKNOWN LOCKING COMPRESSION PLATE/UNKNOWN QUANTITY/UNKNOWN LOT. (B)(4) MALALIGNMENT. THE INVESTIGATION COULD NOT BE COMPLETED AND NO CONCLUSION COULD BE DRAWN, AS NO DEVICE WAS RETURNED AND NO LOT NUMBER OR PART NUMBER WAS PROVIDED. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
THIS REPORT IS BEING FILED AFTER THE SUBSEQUENT REVIEW OF THE FOLLOWING LITERATURE ARTICLE, LAFLAMME, G. ET AL (2008). PERCUTANEOUS HUMERAL PLATING OF FRACTURES OF THE PROXIMAL HUMERUS: RESULTS OF A PROSPECTIVE MULTICENTER CLINICAL TRIAL. J ORTHOP TRAUMA, 22, 153-158. THE AUTHORS CONDUCTED A PROSPECTIVE MULTICENTER CLINICAL TRIAL TO EVALUATE THE SAFETY AND FUNCTIONAL OUTCOME OF PERCUTANEOUS PLATING FOR PROXIMAL HUMERUS FRACTURES USING A PROXIMAL HUMERUS SPECIFIC LOCKING DEVICE, THE SYNTHES FIVE HOLE 3.5 MILLIMETER LOCKING COMPRESSION PLATE. A SPECIFIC TECHNIQUE WAS INVOLVED, USING TWO MINIMAL INCISIONS WITH A LATERAL DELTOID SPLIT AND A MORE DISTAL SHAFT INCISION. FROM FEBRUARY 2002 TO DECEMBER 2003, 34 PATIENTS WERE TREATED: 22 FEMALE, 12 MALE; MEAN AGE WAS 64 YEARS (RANGE, 38-88 YEARS). FOLLOW-UP WAS CONDUCTED TO STUDY THE FUNCTIONAL AND RADIOLOGIC OUTCOMES. TWENTY SEVEN PATIENTS WERE FOLLOWED FOR A MINIMUM OF 12 MONTHS, ON AN AVERAGE OF 19 MONTHS (RANGE, 12-34 MONTHS). SEVEN PATIENTS COULD NOT BE FOLLOWED FOR A MINIMUM OF ONE YEAR; ONE PATIENT DIED FROM UNRELATED CAUSES. RESULTS INCLUDED: ONE PLATE REMOVAL FOR ACROMIAL IMPINGEMENT AT EXTREME ABDUCTION. TWO FRACTURES HEALED WITH MORE THAN 20 DEGREES OF MALALIGNMENT. ALL FRACTURES HEALED WITHIN THE FIRST SIX MONTHS. THIS IS REPORT 1 OF 1 FOR (B)(4). THIS REPORT IS FOR AN UNKNOWN LOCKING COMPRESSION PLATE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 247704 | PLATE, FIXATION, BONE | HRS | SYNTHES USA |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |