FDA Adverse Event Injury Summary report: N

UNKNOWN PROGRIP MESH PRODUCT

MDR report key: 4619358 · Received March 20, 2015

Report

Report Number
9615742-2015-00015
Event Type
Injury
Date Received
March 20, 2015
Report Date
March 2, 2015
Manufacturer
SOFRADIM PRODUCTION
Product Code
FTL
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
BE
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4).

Additional Manufacturer Narrative · 1

(B)(4).

Additional Manufacturer Narrative · 1

(B)(4).

Description of Event or Problem · 1

BACKGROUND : THE LICHTENSTEIN REPAIR IS A WELL STANDARDIZED SURGICAL TECHNIQUE THAT CAN MOSTLY BE PERFORMED IN DAY-CLINIC UNDER LOCAL-REGIONAL ANESTHESIA. THE MAJOR CONCERN IS THE CHRONIC PAIN REPORTED AFTER MESH SUTURE FIXATION. WE STUDIED THE PRACTICAL AND CLINICAL ASPECTS OF A LICHTENSTEIN REPAIR USING THE SEMI-RESORBABLE SELF-FIXATING PARIETEX PROGRIP MESH. METHODS : CONSECUTIVE PATIENTS WITH INGUINAL HERNIA WERE OPERATED ACCORDING TO THE LICHTENSTEIN TECHNIQUE USING PARIETEX PROGRIP {SUP}{/SUP}. COMPLICATIONS WERE ASSESSED. PAIN AND DISCOMFORT WERE EVALUATED AT DISCHARGE, AND AT 1 AND 4 WEEKS AND MINIMUM 6 MONTHS AFTER THE INTERVENTION. RESULTS : 320 PATIENTS WERE INCLUDED IN THE STUDY. NO INTRA-OPERATIVE COMPLICATIONS OR DIFFICULTIES OCCURRED. MEAN OPERATING TIME WAS 36 MINUTES (RANGE 20-65 MINUTES). 87.5% OF THE PATIENTS (280) WERE DISCHARGED AT DAY OF OPERATION, 11.9% (38 PATIENTS) HAD AN OVERNIGHT STAY AND 0.6% (2 PATIENTS) STAYED TWO NIGHTS. MEAN NUMBER OF DAYS OF ANALGESIC USE IS 2.1. AT THE 1 WEEK FOLLOW-UP VISIT, MINOR PAIN OR DISCOMFORT WAS REPORTED BY 45 PATIENTS (14%) AND AT 4 WEEKS 11 PATIENTS (3.4%) STILL HAD MINOR DISCOMFORT. AT 6 MONTHS 1 PATIENT SUFFERED FROM PERSISTING LOCAL NUMBNESS. TWO RECURRENCES WERE NOTED, BOTH WERE RE-OPERATED. CONCLUSIONS : THIS OBSERVATIONAL STUDY CONFIRMS EARLIER FINDINGS WITH THIS SEMI-RESORBABLE SELF-GRIPPING MESH REGARDING OPERATION TIME, COMPLICATIONS AND RECURRENCE. THE OPEN LICHTENSTEIN HERNIA REPAIR WITH THE SEMI-RESORBABLE SELFGRIPPING PARIETEX PROGRIP MESH SEEMS TO OFFER A RELIABLE ALTERNATIVE FOR THE TREATMENT OF INGUINAL HERNIA WITH BENEFITS ON OPERATING TIME AS WELL AS ON POSTOPERATIVE PAIN. ACTA CHIRURGICA BELGICA. 113 (3) (PP 192-195), 2013. DATE OF PUBLICATION: MAY-JUNE 2013.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
191530 UNKNOWN PROGRIP MESH PRODUCT MESH FTL SOFRADIM PRODUCTION

Patients

Seq Age Sex Outcome Treatment
1 Other