FDA Adverse Event Other Summary report: N

MICROLET 2

MDR report key: 4545866 · Received February 19, 2015

Report

Report Number
MW5040891
Event Type
Other
Date Received
February 19, 2015
Date of Event
February 19, 2015
Report Date
February 19, 2015
Manufacturer
BAYER
Product Code
FMK
Report Source
Voluntary report
Reporter Location
ND, US
Reporter Occupation
PHYSICIAN

Narratives

Description of Event or Problem · 1

ITEM: BAYER CONTOUR NEXT EZ LANCET DEVICE AND LANCETS. THE ABOVE PT HAD USED THE LANCET DEVICE AND THE NEEDLE WAS STILL IN THE DEVICE. THE CAP HAS TO BE PULLED OFF TO REMOVE THE LANCET, UNLIKE OTHER DEVICES, SUCH AS THE ONE TOUCH DELICA WHICH EASILY AND SMOOTHLY TWISTS OFF. I WAS FAMILIARIZING MYSELF WITH THE PT'S LANCET DEVICE AND AS I PULLED THE CAP OFF IT GAVE WAY WITH A JERK WHICH CAUSED THE NEEDLE TO EMBED IN THE RING FINGER OF MY LEFT HAND NEAR THE CUTICLE (I AM RIGHT HANDED). THE WOUND SUBSEQUENTLY BLED, CREATING A CONTAMINATED NEEDLE STICK INJURY. I TRIED SEVERAL OTHER TIMES TO REMOVE THE CAP AND FOUND EACH TIME IT GAVE WAY WITH A JERK. THIS MAY BE APPROPRIATE FOR SOME TYPES OF CAPS, BUT NOT WHEN THERE IS A SHARP NEEDLE EXPOSED JUST UNDERNEATH IT. THE PT THEN DEMONSTRATED REMOVAL TECHNIQUE FOR THE LANCET: SHE STATED THE INSTRUCTIONS SAID TO PUSH THE NEEDLE INTO THE ROUND DISK THAT CAME ON THE END OF THE LANCET. IN DOING THIS MANEUVER IT WAS NOTED THE DISK DID NOT STAY ON THE NEEDLE. ULTIMATELY THE PT HAD TO USE A DINNER KNIFE TO WEDGE THE NEEDLE OUT OF THE DEVICE IN ORDER TO GET IT OUT AT ALL, MUCH LESS WITHOUT GETTING STUCK INADVERTENTLY. THE ONE TOUCH DELICA LANCETS HAVE AN ACTUAL CAP THAT GOES OVER THE NEEDLE AS OPPOSED TO A DISK AND IT IS DESIGNED SUCH THAT THE USER CAN THEN GRAB THE CAP AND PULL THE NEEDLE OUT OF THE MACHINE BY IT AND IT STAYS ON, AS DEMONSTRATED BY THIS PT. THE PT WAS REQUIRED BY HER INSURANCE CARRIER, (B)(6), TO CHANGE MACHINES, TEST STRIPS AND LANCETS AND THIS WAS THE DEVICE HER PHARMACY, (B)(6), SENT OVER ON A SCRIPT REQUEST AS THE PREFERRED DEVICE. THIS IS A FAR INFERIOR PRODUCT, POORLY DESIGNED, AND NO DOUBT WILL CREATE MANY OTHER NEEDLE STICK INJURIES, ESPECIALLY AMONG PTS WHO ARE USED TO THE SMOOTH AND SAFE OPERATION OF OTHER PRODUCTS. THIS PT ALSO POINTS OUT MANY DIABETICS ALREADY HAVE NEUROPATHY WHICH MAKES IT DIFFICULT TO GET THE CAP OFF AT ALL AND INCREASES THE LIKELIHOOD OF NEEDLESTICK INJURIES.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
120729 MICROLET 2 LANCET DEVICE FMK BAYER
120730 LANCET LANCET FMK BAYER

Patients

Seq Age Sex Outcome Treatment
1 48 YR Other