SCREW, FIXATION, BONE
Report
- Report Number
- 2520274-2015-10793
- Event Type
- Injury
- Date Received
- February 4, 2015
- Report Date
- January 21, 2015
- Manufacturer
- SYNTHES (USA)
- Product Code
- HWC
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- UK
- Reporter Occupation
- PHYSICIAN
Narratives
DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. PATIENT INFORMATION WAS NOT PROVIDED. THIS REPORT IS FOR TWO UNKNOWN SCREWS. IMPLANT DATE IS UNKNOWN. (B)(6). WITHOUT A LOT NUMBER THE DEVICE HISTORY RECORDS REVIEW COULD NOT BE COMPLETED. THE INVESTIGATION COULD NOT BE COMPLETED; NO CONCLUSION COULD BE DRAWN, AS NO PRODUCT WAS RECEIVED. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
DEVICE REPORT FROM SYNTHES (B)(4) REPORTS AN EVENT IN (B)(60 AS FOLLOWS: DURING A PLANNED REVISION SURGERY TO TREAT A NON-UNION INVOLVING THE EXCHANGE NAILING OF A LATERAL FEMORAL NAIL (LFN) TO BLADE PLATE WITH REAMER/IRRIGATOR/ASPIRATOR (RIA) USED TO COLLECT A GRAFT, THE LFN WAS REMOVED SUCCESSFULLY BUT IT WAS REPORTED THAT THE RIA WAS DIFFICULT TO ASSEMBLE. A PROBLEM WAS ENCOUNTERED WITH GETTING THE INNER REAMING MECHANISM TO COUPLE WITH THE OUTER DISPOSABLE ASPECT. EVENTUALLY THE SYSTEM WAS COUPLED AND THE REAMER HEAD WAS CHECKED TO SEE IT ROTATED FREELY AND THAT WATER FLOWED FROM THE END. ON THE FIRST PASS THE 14.5 REAMER HEAD CAME OFF. THE COUPLING PRONGS HAD SNAPPED AND AS A RESULT THE INNER SLEEVE COULD NOT DISENGAGE FROM THE OUTER DISPOSABLE TUBE. A SHORTER, 340 REAMING ROD WAS THEN USED IN CONJUNCTION WITH A 13.5 REAMER HEAD. A 14.5 REAMING HEAD WAS THEN REQUESTED ALTHOUGH IT WAS INDICATED THAT THE SYSTEM WAS ONLY DESIGNED FOR A SINGLE PASS. TWO ADDITIONAL PASSES WERE PERFORMED WITH THE 14.5 REAMER HEAD. HAVING PLANNED TO REPLACE THE LFN WITH A BLADE PLATE, SOME ANESTHETIC PROBLEMS REQUIRED THAT A CHANGE TO A NAIL. THE LARGEST DIAMETER NAIL WAS REQUESTED. SINCE ONLY A 12MM DIAMETER LFN WAS AVAILABLE, A 14MM PROXIMAL FEMORAL NAIL ¿ ANTIROTATION (PFNA) WAS AVAILABLE AND WAS INSERTED. AFTER THE OPERATION IT WAS NOTED THAT THE INNER REAMING ROD (314.743) HAD LOST A SECTION OF ITS DISTAL TIP. THIS COULD HAVE HAPPENED PRIOR TO THE OPERATION. THE SURGERY WAS PROLONGED ABOUT 20 MINUTES. THE PATIENT WAS IN CRITICAL CONDITION AFTER THE PROCEDURE AND IS IN INTENSIVE CARE UNIT AS A RESULT OF SURGICAL COMPLICATIONS CAUSED BY NUMEROUS FACTORS. THIS COMPLAINT ADDRESSES THE REVISION SURGERY DUE TO NON-UNION. THIS REPORT IS FOR TWO UNKNOWN SCREWS. THIS REPORT IS 1 OF 2 FOR (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 81229 | SCREW, FIXATION, BONE | HWC | SYNTHES (USA) |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |