FDA Adverse Event Injury Summary report: N

ZENITH FLEX AAA ENDOVASCULAR GRAFT BIFURCATED MAIN BODY

MDR report key: 4452569 · Received January 20, 2015

Report

Report Number
1820334-2015-00060
Event Type
Injury
Date Received
January 20, 2015
Date of Event
December 23, 2014
Report Date
January 8, 2015
Manufacturer
COOK, INC.
Product Code
MIH
PMA / PMN Number
P020018
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NC, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THE EVENT IS CURRENTLY UNDER INVESTIGATION.

Additional Manufacturer Narrative · 1

EVENT EVALUATION: A REVIEW OF THE COMPLAINT HISTORY, INSTRUCTIONS FOR USE(IFU) AND TRENDS WAS CONDUCTED FOR THE PURPOSE OF THIS INVESTIGATION. THE COMPLAINT DEVICE WAS NOT BE RETURNED FOR EVALUATION MINIMAL INFORMATION WAS PROVIDED TO ASSIST WITH THIS CASE. IT IS UNCLEAR WHERE THE ISCHEMIA OCCURRED OR IF IT WAS RELATED TO PRE-EXISTING ANATOMICAL CONDITIONS OR USE OF THE DEVICE. THEREFORE, A DEFINITIVE ROOT CAUSE CAN NOT BE DETERMINED OR REPORTED AT THIS TIME. THERE IS NO EVIDENCE TO SUGGEST THAT THE DEVICE WAS NOT MANUFACTURED TO SPECIFICATION. ADDITIONAL ACTION IS NOT REQUIRED AT THIS TIME THE RISK IS INSUFFICIENT PER QUALITY ENGINEER RISK ASSESSMENT, THE RISK REMAINS AT AN ACCEPTABLE LEVEL AS A RESULT OF THIS COMPLAINT. THE APPROPRIATE INTERNAL PERSONNEL HAVE BEEN NOTIFIED MONITORING FOR SIMILAR COMPLAINTS WILL CONTINUE.

Description of Event or Problem · 1

THIS (B)(6) YEAR OLD MALE PT IN THE SPIRAL-Z POST-MARKET REGISTRY ((B)(4)) EXPERIENCED CLINICAL SIGNS INDICATIVE OF LOWER EXTREMITY ISCHEMIA ON (B)(6) 2014 (83 DAYS POST-PROCEDURE). THE PT WAS TREATED ON (B)(6) 2014 FOR AN AORTOILIAC ANEURYSM. THE MAXIMUM AORTIC DIAMETER WAS 6.0 CM. THE PROXIMAL NECK HAD A PARALLEL SHAPE WITH NO PLAQUE/THROMBUS. THE BILATERAL ILIAC ARTERIES HAD MILD TORTUOSITY, NO OCCLUSIVE DISEASE, AND MILD CALCIFICATION. THE PT RECEIVED A MAIN-BODY DEVICE, A LEFT ILIAC LEG, A RIGHT ILIAC LEG. THERE WAS NO DIFFICULTY DEPLOYING ANY OF THE COMPONENTS. AN OCCLUDER DEVICE WAS USED DURING THE PROCEDURE IN AN UNSPECIFIED LOCATION. NO OTHER PROCEDURES WERE PERFORMED. A MOLDING BALLOON WAS USED BUT NO DETAILS WERE PROVIDED REGARDING ITS USE. AT THE CONCLUSION OF THE PROCEDURE, THE DEVICES WERE PATENT WITH NO EXTERNAL COMPRESSION, FLOW-LIMITING KINKS, OR THROMBUS. A TYPE II ENDOLEAK WAS NOTED. ON (B)(6) 2014 (37 DAYS POST-PROCEDURE), THE PT WAS SEEN IN FOLLOW-UP. THERE HAD BEEN NO CHANGE IN THE SIZE OF THE ANEURYSM. DEVICES WERE PATENT WITH NO EXTERNAL COMPRESSION, FLOW-LIMITING KINKS, THROMBUS, ENDOLEAK OR MIGRATION. ON (B)(6) 2014 (83 DAYS POST-PROCEDURE), THE PT EXPERIENCED CLINICAL SIGNS INDICATIVE OF LOWER EXTREMITY ISCHEMIA. NO OTHER INFO REGARDING THE EVENT IS AVAILABLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
44557 ZENITH FLEX AAA ENDOVASCULAR GRAFT BIFURCATED MAIN BODY SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT MIH COOK, INC. NA UNK

Patients

Seq Age Sex Outcome Treatment
1 72 YR Other