COSYCOT INFANT WARMER
Report
- Report Number
- 9611451-2015-00023
- Event Type
- Malfunction
- Date Received
- January 15, 2015
- Report Date
- December 18, 2014
- Manufacturer
- FISHER & PAYKEL HEALTHCARE LTD
- Product Code
- FMT
- PMA / PMN Number
- K934140
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- OH, US
- Reporter Occupation
- BIOMEDICAL ENGINEER
Narratives
(B)(4). WE ARE CURRENTLY IN THE PROCESS OF OBTAINING THE COMPLAINT DEVICE FOR EVALUATION. WE WILL PROVIDE A FOLLOW UP REPORT UPON COMPLETION OF OUR INVESTIGATION.
(B)(4). METHOD: THE COMPLAINT DEVICE WAS NOT RETURNED TO FISHER & PAYKEL HEALTHCARE FOR EVALUATION. THEREFORE, OUR INVESTIGATION IS BASED ON THE INFORMATION PROVIDED BY THE HOSPITAL, PREVIOUS INVESTIGATIONS OF SIMILAR COMPLAINTS AND OUR KNOWLEDGE OF THE PRODUCT. RESULTS: THE HOSPITAL REPORTED THAT THE BOTTOM AND TOP OF THE HEATER HEAD CASE WAS CRACKED. THE SUBJECT INFANT WARMER WAS RELEASED FOR DISTRIBUTION IN 2007 AND IS SEVEN YEARS OLD. A LOT CHECK REVEALED NO OTHER COMPLAINTS OF THIS NATURE FOR LOT 070410. CONCLUSION: WITHOUT THE RETURN OF THE COMPLAINT DEVICE OR PHOTOGRAPHS OF THE REPORTED DAMAGE WE ARE UNABLE TO DETERMINE WHAT MAY HAVE CAUSED THE REPORTED CRACKING. IT IS LIKELY THAT THE REPORTED CRACKING IS RELATED TO A KNOWN PROBLEM OF INCOMPATIBLE CLEANING SOLUTIONS REACTING WITH THE POLYCARBONATE PLASTIC AND ACRYLIC COMPONENTS OF THE INFANT WARMER. WHEN THE HEATER HEAD BEGINS TO WARM UP DURING USE, A CHEMICAL REACTION WITH THE INCOMPATIBLE CLEANING SOLUTION RESULTS IN GRADUAL CRACKING AND CRAZING OF THE HEATER HEAD. THE INFANT WARMER SERVICE MANUAL FEATURES A DIAGRAM OF THE INFANT WARMER WHICH HIGHLIGHTS POLYCARBONATE AND ACRYLIC COMPONENTS AND STATES THE FOLLOWING: THE PLASTIC SURFACES HIGHLIGHTED IN BLACK CONTAIN PLASTIC COMPONENTS MADE FROM POLYCARBONATE OR ACRYLIC, AND INCLUDE THE ENTIRE HEATER ASSEMBLY, BASSINET SIDE PANELS, COLUMN CAP AND FRONT PANEL FASCIAS; CAUTION DO NOT CLEAN THE HIGHLIGHTED PLASTIC SURFACES WITH PROPRIETARY CLEANING PRODUCTS CONTAINING EITHER HYDROXIDES, HYPOCHLORITES, PEROXIDES, GLUTERALDEHYDE OR CLEANING PRODUCTS WITH A GREATER THAN 30% ALCOHOL BASE; CAUTION THE CHEMICALS USED IN THESE PROPRIETARY CLEANING PRODUCTS MAY LEAD TO DISCOLOURATION, CRAZING AND EVENTUAL CRACKING OF THE HIGHLIGHTED PLASTIC SURFACES. OUR CLEANING INSTRUCTIONS RECOMMEND SPECIFIC PROPRIETARY CLEANING WIPES THAT CAN BE USED TO CLEAN THE FRONT PANEL FASCIAS AND OTHER WARMER COMPONENTS.
A HEALTHCARE FACILITY IN (B)(6), REPORTED THAT THE HEATER HEAD CASE OF AN IW934 COSYCOT INFANT WARMER WAS CRACKED. THIS WAS FOUND PRIOR TO PATIENT USE.
A HEALTHCARE FACILITY IN (B)(6), REPORTED THAT THE HEATER HEAD CASE OF AN IW934 COSYCOT INFANT WARMER WAS CRACKED. THIS WAS FOUND PRIOR TO PATIENT USE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 38308 | COSYCOT INFANT WARMER | FMT | FMT | FISHER & PAYKEL HEALTHCARE LTD | IW934 | 070410 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |