CD HORIZON SPINAL SYSTEM
Report
- Report Number
- 1030489-2015-00144
- Event Type
- Injury
- Date Received
- January 14, 2015
- Date of Event
- December 14, 2011
- Report Date
- December 16, 2014
- Manufacturer
- MEDTRONIC SOFAMOR DANEK
- Product Code
- KWP
- PMA / PMN Number
- UNK
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- KS
- Reporter Occupation
- PHYSICIAN
Narratives
LITERATURE CITATION: CHONG SUH LEE, MD, PHD, ET AL. A COMPARATIVE STUDY BETWEEN THORACOSCOPIC SURGERY AND POSTERIOR SURGERY USING AL L-PEDICLE-SCREW CONSTRUCTS IN THE TREATMENT OF ADOLESCENT IDIOPATHIC SCOLIOSIS. J SPINAL DISORD TECH 2013;26:325¿333. (B)(4). THE DEVICE WAS NOT RETURNED FOR EVALUATION HOWEVER FILMS WERE SUPPLIED FOR REVIEW. ANALYSIS RESULTS ARE NOT AVAILABLE AT THE TIME OF THIS REPORT. A FOLLOW-UP REPORT WILL BE SENT WHEN THE ANALYSIS IS COMPLETE.
EVALUATION OF THE FILMS FOUND: 4 FILMS THAT ARE COMPOSITES OF A SCOLIOSIS PATIENT WITH LOWER THORACIC INSTRUMENTATION DONE ANTERIORLY. A PREOP AP AN IMMEDIATE POSTOP AP AND TWO FILMS TAKEN SHOWING LOOSENING OF THE CONSTRUCT AT THE TOP. THE SET SCREWS HAVE COME LOOSE AT T6 AND T7 WITH LOSS OF CORRECTION.
IT WAS REPORTED IN AN ARTICLE TITLED ¿A COMPARATIVE STUDY BETWEEN THORACOSCOPIC SURGERY AND POSTERIOR SURGERY USING ALL-PEDICLE-SCREW CONSTRUCTS IN THE TREATMENT OF ADOLESCENT IDIOPATHIC SCOLIOSIS¿ THAT SIXTY-FIVE PATIENTS WITH LENKE TYPE-1 AIS WERE INCLUDED AND FOLLOWED UP FOR A MINIMUM OF 24 MONTHS. FORTY-TWO PATIENTS UNDERWENT THORACOSCOPIC SURGERY (THORACOSCOPIC GROUP) AND 23 PATIENTS UNDERWENT POSTERIOR SURGERY (POSTERIOR GROUP). RADIOGRAPHIC OUTCOMES, INCLUDING THE CORRECTION RATE AND LOSS OF CORRECTION, PERIOPERATIVE MORBIDITIES, AND COMPLICATIONS, WERE COMPARED. THE THORACOSCOPIC GROUP INCLUDED 35 WOMEN AND 7 MEN. THEIR MEAN AGE WAS 15.9 YEARS, AND THE MEAN FOLLOW-UP DURATION WAS 58.5 MONTHS. THE POSTERIOR GROUP INCLUDED 20 WOMEN AND 3 MEN. THEIR MEAN AGE WAS 14.8 YEARS, AND THE MEAN FOLLOW-UP DURATION WAS 54.3 MONTHS. IN THE THORACOSCOPIC GROUP, THERE WERE 28 LENKE TYPE-1AN CURVES, 9 LENKE TYPE-1BN CURVES, AND 5 LENKE TYPE-1CN CURVES. IN THE POSTERIOR GROUP, THERE WERE 14 LENKE TYPE-1AN CURVES, 4 LENKE TYPE 1-BN CURVES, AND 5 LENKE-TYPE 1-CN CURVES. THE MEAN PREOPERATIVE MAGNITUDE OF THE MAJOR CURVE WAS 52.2 DEGREES IN THE THORACOSCOPIC GROUP AND 55.0 DEGREES IN THE POSTERIOR GROUP, YIELDING NO SIGNIFICANT DIFFERENCE (P=0.348). THE MEAN FLEXIBILITY OF THE MAJOR CURVE ON SIDE-BENDING RADIOGRAPH WAS 63.0% IN THE THORACOSCOPIC GROUP AND 54.9% IN THE POSTERIOR GROUP, SHOWING NO SIGNIFICANT DIFFERENCE (P=0.137). PATIENTS HAD THORACIC KYPHOSIS WITHIN THE RANGE OF 2.0¿47.0 DEGREES IN THE THORACOSCOPIC GROUP AND 1.3¿40 DEGREES IN THE POSTERIOR GROUP. IT WAS REPORTED THAT THE PATIENT HAD A SET SCREW BACK OUT 3 MONTHS POST-OP. THE LOSS OF CORRECTION PROGRESSED UP TO 2 YEARS POST-OP HOWEVER AT 4 YEARS POST-OP THE LOSS HAD RARELY PROGRESSED SO A REVISION SURGERY WAS NOT PERFORMED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 33090 | CD HORIZON SPINAL SYSTEM | APPLIANCE, FIXATION, SPINAL INTERLAMINAL | KWP | MEDTRONIC SOFAMOR DANEK | NA | UNK |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00014 YR | Other |