KINETRA
Report
- Report Number
- 3007566237-2014-03829
- Event Type
- Injury
- Date Received
- December 31, 2014
- Report Date
- December 3, 2014
- Manufacturer
- MEDTRONIC NEUROMODULATION
- Product Code
- MHY
- PMA / PMN Number
- P960009
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- DA
- Reporter Occupation
- HEALTH PROFESSIONAL
Narratives
IT WAS NOT POSSIBLE TO ASCERTAIN SPECIFIC DEVICE INFORMATION FROM THE ARTICLE OR TO MATCH THE EVENTS REPORTED WITH PREVIOUSLY REPORTED EVENTS. CORRESPONDENCE HAS BEEN SENT TO THE AUTHOR OF THE ARTICLE INQUIRING ABOUT PATIENT INFORMATION AND ADDITIONAL INFORMATION REGARDING THE REPORTED EVENTS. CONCOMITANT PRODUCT: PRODUCT ID NEU_UNKNOWN_LEAD, LOT # UNKNOWN, PRODUCT TYPE LEAD; PRODUCT ID NEU_UNKNOWN_EXT, LOT # UNKNOWN, PRODUCT TYPE EXTENSION; PRODUCT ID NEU_UNKNOWN_EXT, LOT # UNKNOWN, PRODUCT TYPE EXTENSION. (B)(4).
THRANE, J.F., SUNDE, N.A., BERGHOLT, B., ROSENDAL, F. INCREASING INFECTION RATE IN MULTIPLE IMPLANTED PULSE GENERATOR CHANGES IN MOVEMENT DISORDER PATIENTS TREATED WITH DEEP BRAIN STIMULATION. STEREOTACTIC AND FUNCTIONAL NEUROSURGERY. SUMMARY: DEEP BRAIN STIMULATION HAS BEEN PERFORMED AT THE DEPARTMENT OF NEUROSURGERY, (B)(6) HOSPITAL, FOR 16 YEARS. THE RISK OF INFECTION RELATED TO IMPLANTABLE PULSE GENERATOR (IPG) REPLACEMENT CONSTITUTES A WEAKNESS IN THE LONG-TERM DBS TREATMENT. THE AIM OF THIS STUDY IS TO INVESTIGATE THE ASSOCIATION BETWEEN RISK OF INFECTION AND NUMBER OF IPG REPLACEMENTS. ALL PATIENTS WHO UNDERWENT IPG REPLACEMENT AT THE (B)(6) FROM (B)(6) 1996 UNTIL (B)(6) 2012 WERE INCLUDED IN THE STUDY, AND THEIR MEDICAL RECORDS WERE SYSTEMATICALLY REVIEWED. THE DATA WAS ANALYZED USING FISHER¿S EXACT TEST ON CONTINGENCY TABLES. TWO HUNDRED TWENTY (220) PROCEDURES OF IPG REPLACEMENT WERE COMPLETED ON 105 PATIENTS WHO SUFFERED FROM VARIOUS MOVEMENT DISORDERS. UP TO 5 IPG CHANGES WERE REGISTERED IN A SINGLE PATIENT. THIRTEEN PATIENTS INCURRED INFECTION REQUIRING SURGICAL INTERVENTION. TESTING FOR RISK OF INFECTION ASSOCIATED WITH NUMBER OF IPG CHANGES, THIS STUDY FOUND SIGNIFICANTLY DIFFERENT INFECTION RATES (P = 0.0052). IN THE GROUPS WITH 3 AND 4 IPG CHANGES, INFECTION RATES REACHED OVER 20%. THIS STUDY FOUND SIGNIFICANTLY DIFFERENT RATES OF INFECTION RELATED TO THE NUMBER OF IPG CHANGES. FURTHER INVESTIGATION AND RESOURCES SHOULD BE DIRECTED TOWARDS IMPROVING THE LIFESPAN OF IPGS. REPORTED EVENTS: ONE (B)(6) MALE PATIENT WITH DEEP BRAIN STIMULATION (DBS) FOR PARKINSON¿S DISEASE EXPERIENCED AN INFECTION WITH PUS DRAINAGE FROM WOUND AND TENDERNESS ALONG THE EXTENSION LEADS FOURTEEN DAYS AFTER AN IMPLANTABLE NEUROSTIMULATOR (INS) REPLACEMENT SURGERY. IT WAS NOTED THAT A CULTURE OF THE WOUND SHOWED STAPHYLOCOCCUS AUREUS. THE PATIENT WAS TREATED WITH DICLOXACILLIN. FOURTEEN DAYS AFTER THE REPLACEMENT SURGERY, THE PATIENT UNDERWENT DEBRIDEMENT WITH GENTACOLL. THIRTY-SIX DAYS AFTER THE REPLACEMENT SURGERY, THE PATIENT HAD THE INS EXPLANTED AND DISCONTINUED TREATMENT. FURTHER INFORMATION HAS BEEN REQUESTED; A SUPPLEMENTAL REPORT WILL BE SUBMITTED IF ADDITIONAL INFORMATION IS RECEIVED. SEE ATTACHED LITERATURE ARTICLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 861716 | KINETRA | STIMULATOR, ELECTRICAL, IMPLANTED, FOR PARKINSONIAN TREMOR | MHY | MEDTRONIC NEUROMODULATION | 7428 | UNKNOWN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00054 YR | Required Intervention |