FDA Adverse Event Injury Summary report: N

UNITEK MULTICURE BI BAND CEMENT, APC II

MDR report key: 4338267 · Received December 5, 2014

Report

Report Number
2020467-2014-00002
Event Type
Injury
Date Received
December 5, 2014
Date of Event
September 1, 2014
Report Date
November 11, 2014
Manufacturer
3M UNITEK
Product Code
DYH
PMA / PMN Number
K950514
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
ME, US
Reporter Occupation
DENTIST

Narratives

Additional Manufacturer Narrative · 1

BOTH THE UNITEK MULTI CURE GLASS IONOMER ORTHODONTIC BAND CEMENT AND THE APC II ADHESIVE-PRECOATED BRACKETS ARE LABELED WITH A WARNING THAT THE PRODUCT CONTAINS ACRYLATES, AND THAT A CERTAIN PERCENTAGE OF THE POPULATION IS KNOWN TO HAVE AN ALLERGIC RESPONSE TO ACRYLATE RESINS.

Description of Event or Problem · 1

ON (B)(6) 2014-INSTALLED TWO 3M STAINLESS STEEL MOLAR BANDS USING UNITEK MULTI CURE GLASS IONOMER ORTHODONTIC BAND CEMENT. ALSO INSTALLED A GAC LIP BUMPER; (B)(6) 2014 - INSTALLED UPPER 5X5 3M PREPASTED METAL BRACKETS; (B)(6) 2014 - CHECKED LIP BUMPER, ALL APPEARED OK; (B)(6) 2014 - PATIENT SEEN AT IMMUNOLOGIST FOR DERMATITIS, BLISTERING, REDNESS OF LIPS AND GUMS. PRESCRIBED MOMETASONE, WHICH SEEMED TO HELP; (B)(6) 2014 - PATIENT RETURNED TO ORTHODONTIST AND ALL COMPONENTS WERE REMOVED. MULTIPLE ITEMS PREPARED FOR PATCH TESTING; (B)(6) 2014 - EVALUATION PREPARED BY IMMUNOLOGIST. FINDINGS/SUSPICIONS SOMEWHAT PRELIMINARY WITH POSSIBLE CROSS CONTAMINATION IN INITIAL PATCH TESTS. REACTIONS WERE CITED TO PIECES OF THE LIP BUMPER NYLON, THE LIP BUMPER WIRE, A GRAY BAND TIE, AND A SAMPLE OF A 3M ADHESIVE SIMILAR TO THAT ON THE PREPASTED BRACKET. THE PREPASTED BRACKET WAS NOT SUBMITTED FOR PATCH TESTING. THE DOCTOR'S INITIAL OPINION WAS THAT THE PATIENT DEVELOPED A SENSITIVITY TO METHACRYLATE OVER TIME AND THAT THE NON-ADHESIVE SAMPLES MAY HAVE HAD A RESIDUE OT THE INITIAL GI BAND CEMENT OR APC II BRACKET ADHESIVE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
786160 UNITEK MULTICURE BI BAND CEMENT, APC II ADHESIVE, BRACKET/TOOTH COND, RESIN DYH 3M UNITEK NA UNK

Patients

Seq Age Sex Outcome Treatment
1 11 YR Required Intervention 3M APC II METAL BRACKETS, UNK MFR ARCHWIRE| GAC LIP BUMPER, UNK MFR GRAY BAND TIE,| 3M MOLAR BANDS,