HOMECHOICE PRO
Report
- Report Number
- 1416980-2014-39894
- Event Type
- Malfunction
- Date Received
- November 11, 2014
- Date of Event
- October 16, 2014
- Report Date
- October 16, 2014
- Manufacturer
- BAXTER HEALTHCARE - LARGO
- Product Code
- FKX
- PMA / PMN Number
- K102936
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- OTHER
Narratives
(B)(4). AN ALARM INDICATIVE OF A POTENTIAL MALFUNCTION OF THE HOMECHOICE MACHINE WAS IDENTIFIED. THE DEVICE WAS RECEIVED FOR ANALYSIS AND AN EVALUATION IS UNDERWAY. SHOULD ADDITIONAL RELEVANT INFORMATION BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED.
(B)(4). THE DEVICE WAS RETURNED TO BAXTER HEALTHCARE FOR FURTHER INVESTIGATION. THE HOMECHOICE DEVICE RECEIVED A RETURNED INSTRUMENT TESTING EVALUATION (RITE). THIS EVALUATION INCLUDED FUNCTIONAL AND ELECTRICAL TESTING OF THE DEVICE. A VISUAL INSPECTION WAS PERFORMED. THE REPORTED IIPV EVENT WAS IDENTIFIED IN THE EVENT HISTORY LOG, BUT NO NON-CONFORMING PRODUCT WAS FOUND DURING SAMPLE ANALYSIS THAT WAS RELATED TO THE REPORTED PROBLEM. REVIEW OF THE SERVICE HISTORY REVEALED THAT PREVIOUS DEVICE SERVICING DID NOT CAUSE OR CONTRIBUTE TO THE REPORTED DIFFICULTY OF IIPV-ADULT. THE CAUSE WAS FALSE EMPTY DETECT AND USE ERROR, CLINICIAN INAPPROPRIATELY SET MINIMUM DRAIN VOLUME PERCENT SETTING TOO LOW. THE HOMECHOICE APD SYSTEMS TRAINER'S GUIDE PROVIDES A WARNING "IF YOU SET THE MINIMUM DRAIN VOLUME % TOO LOW, AN INCOMPLETE DRAIN COULD RESULT FOR THE PATIENT. THIS COULD RESULT IN AN INCREASED INTRAPERITONEAL VOLUME (IIPV) SITUATION." A REVIEW OF THE LABEL FOR THE PRODUCT FAMILY WILL BE CONDUCTED. SHOULD ADDITIONAL RELEVANT INFORMATION BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED.
IT WAS REPORTED THAT A PATIENT RECEIVED A HIGH DRAIN ALARM AFTER THERAPY ON A HOMECHOICE MACHINE. A HIGH DRAIN ALARM INDICATES THE PATIENT DRAINED GREATER THAN 200% OF THE MAXIMUM PRESCRIBED CYCLE FILL VOLUME. THE TECHNICAL SERVICE REPRESENTATIVE ARRANGED TO SWAP THE DEVICE AND DISCUSSED THE USE OF CONTINUOUS AMBULATORY PERITONEAL DIALYSIS (CAPD) UNTIL THE NEW MACHINE ARRIVES. THERE WAS NO PATIENT INJURY OR MEDICAL INTERVENTION IN ASSOCIATION WITH THIS REPORT. NO ADDITIONAL INFORMATION IS AVAILABLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 725696 | HOMECHOICE PRO | SYSTEM, PERITONEAL, AUTOMATIC DELIVERY | FKX | BAXTER HEALTHCARE - LARGO |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 53 YR | EXTRANEAL |