FDA Adverse Event Injury Summary report: N

EDWARDS SAPIEN XT TRANSCATHETER HEART VALVE

MDR report key: 4222141 · Received November 3, 2014

Report

Report Number
2015691-2014-02600
Event Type
Injury
Date Received
November 3, 2014
Date of Event
October 1, 2014
Report Date
October 7, 2014
Manufacturer
EDWARDS LIFESCIENCES
Product Code
NPT
PMA / PMN Number
P130009
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
OH, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

PER THE INSTRUCTIONS FOR USE, PERMANENT OR TRANSIENT NEUROLOGICAL EVENTS INCLUDING STROKE ARE POTENTIAL ADVERSE EVENTS ASSOCIATED WITH THE TAVR PROCEDURE AND THE USE OF THE EDWARDS THV DEVICES. ACCORDING TO LITERATURE REVIEW, AND AS DOCUMENTED IN A CLINICAL TECHNICAL SUMMARY WRITTEN BY EDWARDS LIFESCIENCES, STROKE IS RECOGNIZED IN THE LITERATURE AS A WELL-KNOWN COMPLICATION IN A SMALL NUMBER OF PATIENTS UNDERGOING TAVR. RISK FACTORS CORRELATING WITH A NUMBER OF PATIENT CO-MORBIDITIES HAVE BEEN IDENTIFIED. ALTHOUGH IN MANY CASES THE ROOT CAUSE OF THE EVENT IS UNABLE TO BE DETERMINED, STROKES DURING TAVR ARE UNDOUBTEDLY MULTIFACTORIAL, THE DOMINANT ETIOLOGY LIKELY BEING INTRA-PROCEDURE EMBOLIC EVENTS. A TRANSCRANIAL DOPPLER STUDY DURING TAVR DEMONSTRATED THAT THE MAJORITY OF PROCEDURAL EMBOLIC EVENTS OCCURRED DURING BALLOON VALVULOPLASTY, MANIPULATION OF CATHETERS ACROSS THE AORTIC VALVE, AND VALVE IMPLANTATION. AN ANALYSIS IN PATIENTS UNDERGOING VALVE SURGERY REVEALED FOUR BASELINE CHARACTERISTICS AND TWO PROCEDURAL EVENTS THAT WERE ASSOCIATED WITH EARLY POST-PROCEDURE STROKE: FEMALE SEX, EF < 30%, DIABETES, AGE OLDER THAN 70 YEARS, BYPASS PROCEDURE TIME> 120 MIN, AND CALCIFICATION OF THE ASCENDING AORTA. PREDICTORS OF LATE STROKE HAVE INCLUDED FEMALE SEX, AGE OLDER THAN 75 YEARS, ATRIAL FIBRILLATION, AND A HISTORY OF OR CURRENT SMOKING. THERE WERE NO IMPORTANT DIFFERENCES IN THE FREQUENCY OF LATE STROKES BETWEEN TAVR AND AVR PATIENTS. AFTER TAVR, THERE APPEARS TO BE A MORE SIGNIFICANT PROPORTION OF EARLY STROKES OCCURRING < 24 H POST-PROCEDURE, BUT TAVR PATIENTS WITH MULTIPLE CO MORBIDITIES ARE PROBABLY AT HIGHER RISK OF BOTH EARLY AND LATE STROKES. IN THIS CASE, THE CAUSE FOR THE STROKE IS UNKNOWN; HOWEVER, IT IS POSSIBLE THAT IN ADDITION TO THE PROCEDURE ITSELF, THE PATIENT¿S ADVANCED AGE, AND CO-MORBIDITIES COULD HAVE CONTRIBUTED TO THE EVENT. THE IFU AND TRAINING MANUALS HAVE BEEN REVIEWED AND NO INADEQUACIES HAVE BEEN IDENTIFIED WITH REGARDS TO WARNINGS, CONTRAINDICATIONS, AND THE DIRECTIONS/CONDITIONS FOR THE SUCCESSFUL USE OF THE DEVICE. COMPLAINT HISTORIES FOR ALL REPORTED EVENTS ARE REVIEWED AGAINST TRENDING CONTROL LIMITS ON A MONTHLY BASIS, AND ANY EXCURSIONS ABOVE THE CONTROL LIMITS ARE ASSESSED.

Description of Event or Problem · 1

ONE DAY POST TAVR (THV IN SURGICAL VALVE), THE PATIENT DEVELOPED INCREASED RIGHT SIDED WEAKNESS/NUMBNESS AND TONGUE NUMBNESS. MRI CONFIRMED THE PATIENT HAD SUFFERED AN ISCHEMIC STROKE. DURING THE PROCEDURE, A BAV WAS NOT PERFORMED ON THE SURGICAL VALVE. THE SAPIEN XT VALVE WAS POSITIONED BELOW THE SEWING RING OF THE SURGICAL VALVE, YIELDING ZERO PVL AND ZERO CENTRAL LEAK. AS EXPECTED, THE GRADIENT WAS RATHER ELEVATED (LOW 20S), AND PHYSICIANS ELECTED TO POST-DILATE THE VALVE IN AN ATTEMPT TO REDUCE THE GRADIENT. THE POST-DILATION WAS SUCCESSFUL IN REDUCING THE GRADIENT (LOW 10S AFTER POST-DILATION). THE PATIENT LEFT THE ROOM IN STABLE CONDITION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
702737 EDWARDS SAPIEN XT TRANSCATHETER HEART VALVE AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY DELIVERED NPT EDWARDS LIFESCIENCES 9300TFX23

Patients

Seq Age Sex Outcome Treatment
1 78 YR Other