3.5FR URETHANE UMB CATH
Report
- Report Number
- 3009211636-2014-00105
- Event Type
- Malfunction
- Date Received
- October 20, 2014
- Report Date
- September 22, 2014
- Manufacturer
- COVIDIEN
- Product Code
- FOS
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- SC, US
- Reporter Occupation
- OTHER
Narratives
AN INVESTIGATION IS CURRENTLY UNDERWAY. UPON COMPLETION, THE RESULTS WILL BE FORWARDED. SEVERAL ATTEMPTS TO GATHER INFORMATION FROM THE CUSTOMER WERE MADE TO DATE, NO ADDITIONAL INFORMATION HAS BEEN RECEIVED. IF ADDITIONAL PERTINENT INFORMATION BECOMES AVAILABLE, THE REPORT WILL BE UPDATED.
THE PRODUCT SAMPLE WAS NOT RETURNED TO THE MANUFACTURING SITE FOR REVIEW. THE CUSTOMER REPORTED A LEAK OF THE UVC CATHETER. NO PATIENT INJURY WAS REPORTED. SEVERAL ATTEMPTS TO GATHER INFORMATION FROM THE CUSTOMER WERE MADE. THE CUSTOMER COULD NOT IDENTIFY THE EXACT LOT# OF THE CATHETER USED, BUT PROVIDED POSSIBLE LOT # OF 1415700130. THE POSSIBLE LOT INVOLVED WITHIN THIS COMPLAINT WAS MANUFACTURED ON 08/20/2014 AFTER IMPLEMENTATION OF SPECIAL 510K#K130725. THE DEVICE HISTORY RECORD (DHR) WAS REVIEWED AND NO DEVIATIONS RELATED TO THIS FAILURE MODE WERE FOUND. WITH THE AVAILABLE INFORMATION, THE MOST PROBABLE ROOT CAUSE COULD BE CONSIDERED AS MISUSE (LEAK COULD BE CAUSED DUE TO OVER BENDING OR EXCESSIVE FORCE). HOWEVER WITHOUT THE SAMPLE, THIS CANNOT BE CONFIRMED. UNDER SPECIAL 510K#K130725, COVIDIEN EXPANDED WARNINGS WITHIN THE INSTRUCTIONS FOR USE MANUAL OF THIS PRODUCT TO HIGHLIGHT THE CONCERN OF UVC CATHETER DAMAGE IN THE HUB AREA ASSOCIATED WITH THE USE OF ALCOHOL BASED DISINFECTANTS. THE INSTRUCTIONS FOR USE WERE REPLACED IN ALL STOCK, AND HOSPITALS WERE SENT A LETTER HIGHLIGHTING THIS ISSUE. IT MUST BE NOTED THAT THE INSTRUCTIONS FOR USE (IFU) STATES: DO NOT USE INSTRUMENTS WITH SHARP OR ROUGH EDGES DIRECTLY ON THE CATHETER SINCE EVEN A MINOR CUT COULD TEAR OR BREAK THE CATHETER AND CONTINUES, DO NOT PINCH OR BEND THE CATHETER BACK TO TEMPORARILY OCCLUDE THE CATHETER. THIS CAUSES INCREASED STRESS ON THE CATHETER WHICH CAN LEAD TO A LEAK OR BREAK. DO NOT USE ALCOHOL, ACETONE, OR ALCOHOL CONTAINING ANTISEPTICS DIRECTLY ON THE CATHETER. CAREFULLY CHECK ANTISEPTIC SOLUTIONS FOR ALCOHOL OR ACETONE. THESE SUBSTANCES MAY CAUSE IRREVERSIBLE DAMAGE TO THE POLYURETHANE WHICH CAN LEAD TO A LEAK OR BREAK. ENSURE GLOVES OR OTHER SURFACES WHICH HAVE ALCOHOL ON THEM ARE COMPLETELY DRY BEFORE TOUCHING OR MANIPULATING THE CATHETER. ALSO UNDER THE...
IT WAS REPORTED TO COVIDIEN ON (B)(6) 2014 THAT A CUSTOMER HAD AN ISSUE WITH A SINGLE LUMEN UMBILICAL VESSEL CATHETER (UVC). THE CUSTOMER REPORTS THAT THE UVC DEVELOPED A LEAK. THERE WAS NO PATIENT HARM. THE CUSTOMER FURTHER REPORTS THAT THEY CHANGED OUT THE CATHETER AND HAD DIFFICULTY GETTING ANOTHER ONE BACK IN.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 666577 | 3.5FR URETHANE UMB CATH | UMBILICAL VESSEL CATHETER | FOS | COVIDIEN | 8888160333 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |