RECLAIM DISTAL TAPERED 19X190
Report
- Report Number
- 1818910-2014-29529
- Event Type
- Malfunction
- Date Received
- October 7, 2014
- Date of Event
- February 26, 2014
- Report Date
- February 26, 2014
- Manufacturer
- DEPUY ORTHOPAEDICS, INC.
- Product Code
- KWA
- PMA / PMN Number
- PK102080
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- US
- Reporter Occupation
- PHYSICIAN
Narratives
THE DEVICE ASSOCIATED WITH THIS REPORT WAS NOT RETURNED. REVIEW OF THE DEVICE HISTORY RECORDS AND/OR A LOT SPECIFIC COMPLAINT DATABASE SEARCH WAS NOT POSSIBLE AS THE LOT CODE REQUIRED WAS NOT PROVIDED. DEPUY ORTHOPAEDICS, INC. ISSUED A VOLUNTARY DEVICE CORRECTION OF ALL LOTS OF THE RECLAIM® TAPER SLEEVE PROTECTOR INSTRUMENT BECAUSE THE PRODUCT CAN BE DIFFICULT TO REMOVE FROM THE DISTAL STEM BOTH BEFORE SURGERY AND AFTER PROXIMAL REAMING. THE IMMEDIATE REMEDY IS FOR ALL USERS TO DISCARD THE AFFECTED TAPER SLEEVE PROTECTOR PRIOR TO STEM IMPLANTATION. NO FURTHER CORRECTIVE ACTION IS FOUND NECESSARY. (B)(4).
THE DEVICE ASSOCIATED WITH THIS REPORT WAS NOT RETURNED. REVIEW OF THE DEVICE HISTORY RECORDS AND/OR A LOT SPECIFIC COMPLAINT DATABASE SEARCH WAS NOT POSSIBLE AS THE LOT CODE REQUIRED WAS NOT PROVIDED. DEPUY ORTHOPAEDICS, INC. ISSUED A VOLUNTARY DEVICE CORRECTION OF ALL LOTS OF THE RECLAIM® TAPER SLEEVE PROTECTOR INSTRUMENT BECAUSE THE PRODUCT CAN BE DIFFICULT TO REMOVE FROM THE DISTAL STEM BOTH BEFORE SURGERY AND AFTER PROXIMAL REAMING. THE IMMEDIATE REMEDY IS FOR ALL USERS TO DISCARD THE AFFECTED TAPER SLEEVE PROTECTOR PRIOR TO STEM IMPLANTATION. NO FURTHER CORRECTIVE ACTION IS FOUND NECESSARY. MONITOR VIA SEP-419. DEPUY CONSIDERS THE INVESTIGATION CLOSED AT THIS TIME. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THE INFORMATION WILL BE REVIEWED AND THE INVESTIGATION WILL BE RE-OPENED AS NECESSARY.
I WAS INFORMED THAT WHEN THE SURGEON USED THE PROXIMAL REAMER PER PAGE 13 OF THE SURGICAL TECHNIQUE (0612-62-511 VERSION 2 ISSUED: 10/13), THE TAPER PROTECTOR BEGAN TO MELT MAKING IT VERY DIFFICULT TO REMOVE FROM THE STEM CAUSING A MINOR DELAY (LESS THAN 5 MINUTES). THE SURGEON ALSO COMPLAINED THAT EVEN WITHOUT COMPLETING THE PROXIMAL REAMING STEP THE TAPER PROTECTOR IS VERY DIFFICULT TO GET OFF.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 627251 | RECLAIM DISTAL TAPERED 19X190 | HIP FEMORAL STEM/SLEEVE | KWA | DEPUY ORTHOPAEDICS, INC. | UNKNOWN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |