FDA Adverse Event Injury Summary report: N

CELSIOR

MDR report key: 4092239 · Received August 20, 2014

Report

Report Number
2950168-2014-12601
Event Type
Injury
Date Received
August 20, 2014
Report Date
August 14, 2014
Manufacturer
GENZYME POLYCLONALS S.A.S.
Product Code
MSB
PMA / PMN Number
K991594
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
SC, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

SERIOUSNESS CRITERIA: MEDICAL SIGNIFICANT. PHARMACOVIGILANCE COMMENT: (B)(4) COMMENT DATED (B)(4) 2014: THIS CASE CONCERNS (B)(6) PTS WHO DEVELOPED DELAYED GRAFT FUNCTION AFTER UNDERGOING HEART TRANSPLANTATIONS AFTER USING CELSIOR ORGAN PRESERVATION SOLUTION FOR ORGAN PRESERVATION. ALTHOUGH THE ROLE OF THE ORGAN PRESERVATION SOLUTION CANNOT BE RULED OUT BASED ON THE DEVICE EVENT TEMPORAL RELATIONSHIP; HOWEVER, LACK OF DETAILED INFORMATION ABOUT MEDICAL HISTORY, LAB DATA, ANY CONCURRENT MEDICAL ILLNESSES, CLINICAL COURSE ETC. OF THE PT PRECLUDES A COMPREHENSIVE ASSESSMENT IN THIS CASE.

Description of Event or Problem · 1

THIS UNSOLICITED DEVICE CASE FROM UNITED STATES WAS RECEIVED ON (B)(6) 2014 FROM OTHER HEALTH CARE PROFESSIONAL. THIS CASE HAS BEEN CROSS REFERRED WITH CASE (B)(4) (CLUSTER). THIS CASE INVOLVES 5 PTS WHO EXPERIENCED DELAYED GRAFT FUNCTION AFTER UNDERGOING HEART TRANSPLANTATIONS, WHICH WERE PRESERVED WITH CELSIOR ORGAN PRESERVATION SOLUTION (CELSIOR). NO PAST DRUGS, MEDICAL HISTORY, CONCURRENT CONDITIONS OR CONCOMITANT MEDICATIONS WERE REPORTED. ON UNK DATES, THE HEARTS FOR TRANSPLANT WERE PRESERVED IN CELSIOR, SOLUTION FOR ORGAN PRESERVATION. ON UNK DATES, THE PTS UNDERWENT HEART TRANSPLANT. ON UNK DATES, AFTER AN UNSPECIFIED LATENCY PERIOD, THE PTS HAD DELAYED GRAFT FUNCTION. IT WAS REPORTED THAT THE PTS EXPECTED TO HAVE GOOD OUTCOMES BUT THEY DID NOT. NO CORRECTIVE TREATMENT WAS REPORTED. OUTCOME: UNK. A PHARMACEUTICAL TECHNICAL COMPLAINT (PTC) WAS INITIATED AND THE RESULTS WERE PENDING FOR THE SAME.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
500687 CELSIOR ORGAN PRESERVATION SOLUTION MSB GENZYME POLYCLONALS S.A.S. UNK

Patients

Seq Age Sex Outcome Treatment
1 CON MEDS| PREV MEDS